Summary

Product identification

The TurboClean® High Temp NF Elements from MANN+HUMMEL Water & Fluid Solutions are designed for continuous operation at temperatures up to 80°C. These elements feature a patented sanitary hard-shell design offering approximately 60% less bypass flow than other sanitary elements, increased strength, and resistance to higher pressure drops. They also boast tight OD tolerance and optimal circularity for easier loading and unloading.

Key Benefits:

  • Strongest Sanitary Element
  • Most Effective Cleaning
  • Longer Operating Life
  • Easiest Installation
  • Better Performance

Membrane Characteristics

MembraneMembrane TypeStabilized MgSO₄ Rejection (%)Minimum MgSO₄ Rejection (%)
TS80Polyamide99.2%98.5%
TS40Polypiperazine99.0%98.5%
XN45Polypiperazine96.0%94.0%
UA60Polypiperazine80.0%70.0%

Operating limits

  • Maximum Operating Temperature: 80°C (176°F)
  • Maximum Operating Pressure:
    • 32.2 bar (470 psi) at 60°C (140°F)
    • 27.6 bar (400 psi) at 70°C (158°F)
    • 24.1 bar (350 psi) at 80°C (176°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm
  • Maximum Pressure Drop:
    • At 30°C: 1.4 bar (20 psi) per element; 6 bar (80 psi) per housing
    • At 70°C: 0.3 bar (5 psi) per element; 1.4 bar (20 psi) per housing

Mechanical / hydraulic

All models on this sheet feature a TurboClean sanitary outer wrap and parallel feed spacers. The 4040 and 8040 models include anti-telescoping devices (ATDs) attached to the ends of the element and one interconnector. Male elements have a protruding permeate tube with Dimension "D" of 25.4 mm (1.0 in).

Design Information

  • TurboClean® HT 3838-TS80-47P
    • Membrane Area: 5.2 m² (54 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8038-TS80-47P
    • Membrane Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8040-TS80-47P
    • Membrane Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 3838-TS40-47P
    • Membrane Area: 5.2 m² (54 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 4040-TS40-47P
    • Membrane Area: 5.6 m² (60 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8038-TS40-47P
    • Membrane Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8040-TS40-47P
    • Membrange Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 3838-XN45-47P
    • Membrane Area: 5.2 m² (54 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 4040-XN45-47P
    • Membrane Area: 5.6 m² (60 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8040-XN45-47P
    • Membrane Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 3838-UA60-47P
    • Membrane Area: 5.2 m² (54 ft²)
    • Feed Spacer Thickness: 47 mil
  • TurboClean® HT 8040-UA60-47P
    • Membrane Area: 26.5 m² (285 ft²)
    • Feed Spacer Thickness: 47 mil

Physical Dimensions

  • TurboClean® HT 3838-TS80-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 96 mm (3.8 inches)
    • Dim. C (Inner Diameter): 21.2 mm (0.83 inches)
    • Permeate Tube: Female
  • TurboClean® HT 8038-TS80-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female
  • TurboClean® HT 8040-TS80-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female
  • TurboClean® HT 3838-TS40-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 96 mm (3.8 inches)
    • Dim. C (Inner Diameter): 21.2 mm (0.83 inches)
    • Permeate Tube: Female
  • TurboClean® HT 4040-TS40-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 99 mm (3.9 inches)
    • Dim. C (Outer Diameter): 19.1 mm (0.75 inches)
    • Permeate Tube: Male
  • TurboClean® HT 8038-TS40-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female
  • TurboClean® HT 8040-TS40-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female
  • TurboClean® HT 3838-XN45-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 96 mm (3.8 inches)
    • Dim. C (Inner Diameter): 21.2 mm (0.83 inches)
    • Permeate Tube: Female
  • TurboClean® HT 4040-XN45-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 99 mm (3.9 inches)
    • Dim. C (Outer Diameter): 19.1 mm (0.75 inches)
    • Permeate Tube: Male
  • TurboClean® HT 8040-XN45-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female
  • TurboClean® HT 3838-UA60-47P
    • Element Weight: 4 kg (9 lb)
    • Dim. A: 965 mm (38.0 inches)
    • Dim. B: 96 mm (3.8 inches)
    • Dim. C (Inner Diameter): 21.2 mm (0.83 inches)
    • Permeate Tube: Female
  • TurboClean® HT 8040-UA60-47P
    • Element Weight: 16 kg (36 lb)
    • Dim. A: 1,016 mm (40.0 inches)
    • Dim. B: 201 mm (7.9 inches)
    • Dim. C (Inner Diameter): 28.6 mm (1.125 inches)
    • Permeate Tube: Female

Certifications and Regulatory Compliance

  • All models use FDA (CFR Title 21) compliant materials.
  • Comply with EU regulation (EC) No. 1935/2004 and No. 10/2011.
  • Halal and Kosher certifications.
  • All 38-inch long models conform to USDA 3A sanitary standard 45-03.

Important Information

  • Start-up: MANN+HUMMEL Water & Fluid Solutions recommends flushing elements for 30 minutes at low pressure and discarding permeate during the flush prior to operation. Refer to the Element Start-Up Guide – System Start-Up (TSG-O-005) for detailed procedures.
  • Cleaning: TurboClean® membrane elements require periodic cleaning to ensure proper operation and prevent damage. Refer to the Membrane Cleaning Guides.
  • Storage: TurboClean membrane elements must be stored appropriately. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).
  • Customizable Specialty Elements: MANN+HUMMEL Water & Fluid Solutions offers a full range of membranes and element designs for challenging water and process applications, including low-fouling RO, submerged UF, continuous high temperature, ultra-high pressure, and unique sanitary designs.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. For contractual data and complete information, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.