Datasheet summary
HP Low Energy
Engineering summary from PDF text extraction for HP Low Energy. Verify every value with the OEM datasheet.
Summary
Product Identification
TurboClean® High Purity Low Energy RO elements are designed for applications demanding ultrapure water, such as dialysis, pharmaceutical, and semiconductor rinse water. These elements feature a unique, sanitary, patented hard-shell construction that offers better value and about 60% less bypass flow compared to net-wrapped elements.
Available Models:
- TurboClean® HP 4040-RO-LE-M
- Part Number: 164024441
- TurboClean® HP 4040-RO-LE-F
- Part Number: 164320442
Membrane Characteristics
- Membrane: RO-LE
- Membrane Type: Polyamide
- Stabilized Salt Rejection: 98.5%
- Minimum Salt Rejection: 98.0%
Operating Limits
- Maximum Operating Pressure: 41 bar (600 psi)
- Maximum Operating Temperature: 50°C (122°F)
- Cleaning pH Range: 1.0 – 12.0
- Chlorine Tolerance: < 0.1 ppm
- Maximum Pressure Drop:
- 1.4 bar (20 psi) per element
- 6 bar (80 psi) per housing
- Maximum SDI₁₅: 5.0
- Maximum Turbidity: 1 NTU
Performance Data
Test Conditions: 2,000 ppm NaCl, 10.3 bar (150 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.
- TurboClean® HP 4040-RO-LE-M
- Permeate Flow: 9.1 m³/day (2,400 GPD)
- Membrane Area: 7.4 m² (80 ft²)
- Feed Spacer Thickness: 31 mil
- TurboClean® HP 4040-RO-LE-F
- Permeate Flow: 9.1 m³/day (2,400 GPD)
- Membrane Area: 7.4 m² (80 ft²)
- Feed Spacer Thickness: 31 mil
Mechanical / Hydraulic
All models feature a TurboClean sanitary outer wrap, diamond-shaped feed spacers, and include anti-telescoping devices (ATDs) attached to the ends of the element and one interconnector. A brine seal is not included or required.
- TurboClean® HP 4040-RO-LE-M
- Element Weight: 4 kg (9 lb)
- Dim. A (Length): 1,016 mm (40.0 inches)
- Dim. B (Outer Diameter): 99 mm (3.9 inches)
- Dim. C (Permeate Tube Outer Diameter): 19.1 mm (0.75 inches)
- Permeate Tube: Male (protruding 25.4 mm (1.0 in))
- TurboClean® HP 4040-RO-LE-F
- Element Weight: 4 kg (9 lb)
- Dim. A (Length): 1,016 mm (40.0 inches)
- Dim. B (Outer Diameter): 99 mm (3.9 inches)
- Dim. C (Permeate Tube Inner Diameter): 15.9 mm (0.625 inches)
- Permeate Tube: Female
Regulatory
All models use FDA (CFR Title 21) compliant materials.
Important Information
- Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation. Refer to the Element Start-Up Guide – System Start-Up (TSG-O-005) for detailed procedures.
- Cleaning: Elements require periodic cleaning to ensure proper operation and prevent membrane damage. Refer to the Membrane Cleaning Guide – Water Application Elements (TSG-C-001).
- Storage: Elements must be stored appropriately to ensure proper operation and prevent membrane damage. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the original OEM PDF datasheet. For contractual data and complete information, the specific OEM PDF revision used on the project must be consulted.