Datasheet summary
NF 8038 NP 030 XT
Engineering summary from PDF text extraction for NF 8038 NP 030 XT. Verify every value with the OEM datasheet.
Summary
Product identification
The TurboClean® Food & Dairy NP030 XT Series elements feature a membrane cast on a polypropylene support material suitable for high temperature and high pH cleaning conditions. These elements incorporate patented TurboClean technology, a sanitary hard-shell design that reduces bypass flow by approximately 60% compared to other sanitary elements, leading to energy savings and/or higher flux rates. This design also enables more effective membrane cleaning and allows the elements to withstand higher pressure drops.
Model: TurboClean® NF 8038-NP030XT-46
Key Features:
- Strongest Sanitary Element
- Most Effective Cleaning
- Longer Operating Life
- Easiest Installation
- Better Performance
Membrane Characteristics
- Membrane: NP030 XT
- Membrane Type: Polyethersulfone (PES)
- Nominal M.W.C.O.: 500 – 600 Da
- Na₂SO₄ Salt Rejection: 80 – 95%
Operating limits
- Maximum Operating Pressure: 41 bar (600 psi)
- Maximum Operating Temperature: 60°C (140°F)
- Maximum Cleaning Temperature: 75°C (167°F)
- Maximum Sanitization Temperature: 85°C (185°F) at 1.7 bar max pressure, pH 6.0 – 8.0
- Cleaning pH Range: 1.0 – 13.0
- Cleaning Chlorine Tolerance: 200 ppm for sanitization at pH ≥ 10.5
- Maximum Pressure Drop: 1.4 bar (20 psi) per element; 6 bar (80 psi) per housing
Mechanical / hydraulic
- Membrane Area: 23.7 m² (255 ft²)
- Feed Spacer Thickness: 46 mil (diamond shaped feed spacers)
- Element Weight: 16 kg (36 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. C (Inner Diameter): 201 mm (7.9 inches)
- Permeate Tube: 28.6 mm (1.125 inches), Female
Regulatory Compliance
This model:
- Conforms to USDA 3A sanitary standard 45-03
- Uses FDA (CFR Title 21) compliant materials
- Complies with EU regulation (EC) No. 1935/2004 and No. 10/2011
- Has Halal and Kosher certifications
Important Information
- Start-up: MANN+HUMMEL Water & Fluid Solutions recommends flushing elements for 30 minutes at low pressure and discarding permeate during the flush prior to operation. For a more detailed procedure, refer to Element Start-Up Guide – System Start-Up (TSG-O-005).
- Cleaning: TurboClean® membrane elements require periodic cleaning. Refer to Membrane Cleaning Guide – Food & Dairy: XT Elements (TSG-C-007).
- Storage: Proper storage is necessary for optimal operation and to prevent damage. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the most recent revisions. Contractual data must match the OEM PDF revision used on the project.