Datasheet summary
FB02-FC -FUS1582
Engineering summary from PDF text extraction for FB02-FC -FUS1582. Verify every value with the OEM datasheet.
Summary
Product identification
The ULTRADYN™ FB02-FC-FUS1582 are Ultrafiltration Modules designed for high levels of purification and high packing density. They feature high mechanical strength and backwashable membranes.
The modules are available with polyethersulfone (PES), polyacrylonitrile (PAN), and cellulose tri-acetate (CTA) hollow fiber membrane types. They can be sterilized with hot water up to 98 °C to eliminate bacterial growth and prevent fouling.
ULTRADYN modules are suited for applications such as pure water filtration, pharmaceuticals, electronics, and surface water treatment. Hollow fiber inner diameters range from 0.5 to 1.4 mm, and module sizes range from 0.1 m² to 17 m².
Membrane Characteristics
- Membrane Chemistry: Polyethersulfone (PES)
- Molecular Weight Cut-Off: 150,000 Dalton
- Hollow Fiber Inner Diameter: 0.8 mm
Physical Dimensions
The module components and their materials are as follows:
- Hollow Fiber: Polyethersulfone
- Cap: Polysulfone (Quantity: 2)
- Case: Polysulfone (Quantity: 1)
- O-Ring type AS568-239: Fluoro-rubber (FPM) (Quantity: 2)
- Potting Resin: Epoxy Resin
Key dimensions (in mm):
- A: 356
- B: 250
- C: 53
- D: Ø 60
- E: Ø 45
- F: 42
Operating limits
- Maximum Feed Inlet Pressure: 4 bar (58 psi)
- Maximum Transmembrane Pressure: 3 bar (44 psi)
- Maximum Temperature: 98°C (208°F)
- Applicable pH range: 1 ~ 13
Operating parameters
- Membrane Area: 0.25 m² (2.69 ft²)
- Standard Water Flux: 360 l/h (1.58 gpm)
- Shipping Water Flux: 253 l/h (1.11 gpm)
- Standard Inlet Feed Flow: 690 l/h (3.04 gpm)
- Operating Weight: 0.9 kg (1.98 lb)
- Shipping Weight: 0.4 kg (0.88 lb)
- Standard Preservative: 1000 ppm Benzoic acid
Mechanical / hydraulic
- Feed/Concentrate Connectors: G1/2
- Permeate Connectors: G1/2
The ULTRADYN™ product line offers a full range of membranes and element designs for challenging water and process applications, including low-fouling RO, submerged UF, continuous high temperature, ultra-high pressure, and unique sanitary designs.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.