These are Structural Composite Pressure Vessels, featuring reinforced fiberglass construction for water treatment and storage.
Product Features
- For commercial and industrial water treatment and storage
- 100% composite fiberglass construction
- Outstanding performance and durability in harsh chemical environments
- Absolutely will not – and cannot – rust
- Requires little or no maintenance
- Capacities up to 1600 gallons
- Factory-backed five-year warranty
- Commercial softening & filtration
Color Options
- AL - Almond
- BL - Blue
- BK - Black
- GR - Gray
- NA - Natural
Specifications
| Part No. | Description | Height w/base (inches/mm) | Height w/o base (inches/mm) | Capacity (Gallons/Liters) | Cubic Feet | Base | Ship Weight (lbs.) |
|---|---|---|---|---|---|---|---|
| 18" Dia. | |||||||
| CH30948 | 18X65 COMP 4"T | 66.95 / 1701 | 65.07 / 1669 | 64 / 242 | 8.56 | SMC | 67 |
| CH31343 | 18X65 COMP 4"T 4"B | 73.13 / 1858 | 65.6 / 1394 | 64 / 242 | 8.56 | SMC EXT | 67 |
| CH31693 | 18X65 COMP 6"TF 6"BF | 84.12 / 2137 | 70.5 / 1791 | 62 / 234 | 8.29 | SMC EXT | 92 |
| 21" Dia. | |||||||
| CH30950 | 21X36 COMP 4"T | 41.7 / 1059 | 38.2 / 970 | 45 / 171 | 6.06 | SMC | 46 |
| CH31573 | 21X36 COMP 4"T 4"B | 47.5 / 1205 | 38.25 / 970 | 45 / 171 | 6.06 | SMC EXT | 53 |
| CH30953 | 21X62 COMP 4"T | 67.0 / 1702 | 63.4 / 1610 | 84 / 318 | 11.23 | SMC | 95 |
| CH30954 | 21X62 COMP 4"T 4"B | 72.8 / 1848 | 63.5 / 1613 | 84 / 318 | 11.23 | SMC EXT | 95 |
| 24" Dia. | |||||||
| CH31043 | 24X38 COMP 4"T | 42.6 / 1081 | 38.5 / 978 | 61 / 231 | 8.15 | SMC | 65 |
| CH31053 | 24X50 COMP 4"T | 58 / 130 | 52.9 / 1343 | 83.5 / 316 | 11.16 | SMC | 90 |
| CH31611 | 24X50 COMP 4"T 4"B | 63 / 1601 | 52.9 / 1343 | 83.5 / 316 | 11.16 | SMC EXT | 90 |
| CH32049 | 24X65 COMP 4"T | 65.2 / 1655 | 61.1 / 1552 | 100 / 378 | 13.36 | SMC | 109 |
| CH32481 | 24X65 COMP 4"T 4"B | 70.1 / 257 | 60 / 1524 | 100 / 378 | 13.36 | SMC EXT | 115 |
| CH32129 | 24X65 COMP 6"TF | 65 / 1651 | 61.2 / 1556 | 100 / 378 | 13.36 | SMC | 114 |
| CH32139 | 24X65 COMP 6"TF 6"BF | 79 / 2007 | 65 / 1651 | 100 / 378 | 13.36 | TRIPOD | 114 |
| CH31153 | 24X72 COMP 4"T | 74.2 / 1884 | 70.12 / 1781 | 118 / 451 | 15.77 | SMC | 109 |
| CH31154 | 24X72 COMP 4"T 4"B | 80.4 / 2043 | 70.3 / 1786 | 118 / 451 | 15.77 | SMC EXT | 124 |
| CH31155 | 24X72 COMP 6"TF | 77 / 1956 | 73.4 / 1864 | 118 / 451 | 15.77 | SMC | 137 |
| CH31157 | 24X72 COMP 6"TF 6"BF | 88.5 / 2248 | 74.5 / 1892 | 118 / 451 | 15.77 | TRIPOD | 137 |
| 30" Dia. | |||||||
| CH34177 | 30X60 COMP 6"TF | 71.6 / 1819 | 64.3 / 1634 | 151 / 572 | 20.2 | SMC EXT | 195 |
| CH34178 | 30X60 COMP 6"TF 6"BF | 82.5 / 2096 | 68.5 / 1740 | 151 / 572 | 20.2 | TRIPOD | 195 |
| CH33653 | 30X72 COMP 4"T | 77.2 / 1961 | 69.8 / 1772 | 187 / 708 | 24.99 | SMC EXT | 198 |
| CH31161 | 30X72 COMP 4"T 4"B | 77.2 / 1961 | 69.8 / 1772 | 187 / 708 | 24.99 | SMC EXT | 198 |
| CH31162 | 30X72 COMP 6"TF | 79.7 / 2025 | 69.9 / 1778 | 187 / 708 | 24.99 | SMC EXT | 195 |
| CH311613 | 30X72 COMP 6"TF 6"BF | 88.9 / 2258 | 74.9 / 1903 | 187 / 708 | 24.99 | SMC EXT | 211 |
| 36" Dia. | |||||||
| CH31209 | 36X36 COMP 6"TBF | 55.3 / 1403 | 41 / 1041 | 118 / 447 | 15.8 | TRIPOD | 148 |
| CH31417 | 36X57 COMP 6"TF | 68 / 1727 | 59.3 / 1505 | 205 / 776 | 27.4 | SMC EXT | 225 |
| CH31418 | 36X57 COMP 6"TF 6"BF | 77.3 / 1962 | 63 / 1600 | 205 / 776 | 27.4 | TRIPOD | 225 |
| CH33652 | 36X72 COMP 4"T | 80.4 / 2042 | 71.8 / 1823 | 264 / 999 | 35.2 | SMC EXT | 264 |
| CH31523 | 36X72 COMP 4"T 4"B | 80.5 / 2045 | 70.5 / 1791 | 264 / 999 | 35.2 | SMC EXT | 285 |
| CH31214 | 36X72 COMP 6"TF | 83 / 2108 | 74.3 / 1886 | 264 / 999 | 35.2 | SMC EXT | 285 |
| CH31217 | 36X72 COMP 6"TF 6"BF | 90.4 / 2296 | 76.1 / 1934 | 264 / 999 | 35.2 | TRIPOD | 285 |
| CH31712 | 36X72 COMP 6"TF 6"BF 4"TBSF | 89.6 / 2275 | 75.3 / 1913 | 264 / 999 | 35.2 | TRIPOD | 292 |
| 42" Dia. | |||||||
| CH31272 | 42X72 COMP 6"TF | 72.5 / 1842 | 71.1 / 1807 | 345 / 1306 | 46.1 | SMC | 370 |
| CH31276 | 42X72 COMP 6"TF 6"BF | 90.1 / 2289 | 73 / 1854 | 345 / 1306 | 46.1 | TRIPOD | 400 |
| CH34226 | 42X72 COMP 6"TF 6"BF 4"TBSF | 94.6 / 2403 | 77.5 / 1969 | 345 / 1306 | 46.1 | TRIPOD | 415 |
| 48" Dia. | |||||||
| CH31281 | 48X72 COMP 6"TF | 81.5 / 2071 | 75.2 / 1909 | 463 / 1753 | 61.9 | SMC | 494 |
| CH31285 | 48X72 COMP 6"TF 6"BF | 92.9 / 2360 | 76.9 / 1953 | 463 / 1753 | 61.9 | TRIPOD | 494 |
| CH31283 | 48X72 COMP 6"TF 6"BF 4"TBSF | 96.75 / 2458 | 80.75 / 2051 | 463 / 1753 | 61.9 | TRIPOD | 504 |
| 63" Dia. | |||||||
| CH31390 | 63X67 COMP 6"TF 6"BF | 81.4 / 2068 | 67.1 / 1704.3 | 600 / 2271 | 80.2 | TRIPOD | 680 |
| CH31326 | 63X86 COMP 6"TF 6"BF | 98.5 / 2503 | 84.1 / 2136 | 900 / 3407 | 120.3 | TRIPOD | 950 |
| CH31327 | 63X86 COMP 16"TMWY 6"BF | 98.9 / 2513 | 84.5 / 2146 | 900 / 3407 | 120.3 | TRIPOD | 950 |
| CH31292 | 63X86 COMP 16"TMWY 6"BF 4"TBSF | 99 / 2515 | 85 / 2159 | 900 / 3407 | 120.3 | TRIPOD | 950 |
| CH34234 | 63X116 16"TMWY 6'BF 4"TBSF | 130.4 / 3312 | 115.9 / 2945 | 1250 / 4732 | 167 | TRIPOD | 1190 |
| CH31607 | 63X144 16"TMWY 6'BF 4"TBSF | 157.9 / 4012 | 143.9 / 3656 | 1600 / 6057 | 214 | TRIPOD | 1398 |
Material of Construction
- Polyethylene inner shell
Operating limits
- Maximum operating pressure: 150 psi
- Maximum operating temperature:
- 120°F (threaded)
- 150°F (flanged)
Design Parameters
Pentair Design Parameters
- Safety factor: 4:1
- Minimum burst at 600 psi
- Tested to 250,000 cycles without leakage
NSF Design Parameters
- Safety factor: 4:1
- Minimum burst at 600 psi
- Tested to 100,000 cycles without leakage
ASME Design Parameters
- Top/Bottom flange:
- Safety factor: 5:1
- Minimum burst at 750 psi
- Tested to 33,000 cycles without leakage
- Side flange:
- Safety factor: 6:1
- Minimum burst at 900 psi
- Tested to 100,000 cycles without leakage
Installation Tips
- Bolt base to floor
- Calculate height for valve and base combined (see photo in official PDF)
Fleck Valve Adder Height
| Tank Dia. (inches/mm) | Adder Ht. (X) (inches/mm) |
|---|---|
| 18/457 | 6.5/165 |
| 21/533 | 6.5/165 |
| 24,30/610,762 | 12/305 |
| 3150 | 10/254 |
| 3900 | 15/381 |
Dome Volume (gallons) and Straight Wall Gallon per Inch
(Nominal Diameter)
| D (inches) | Gallons* (One Dome) | Gallon/Inch (Approx.) | A (Sq. Feet) |
|---|---|---|---|
| 12 | 1.0 | 0.5 | 0.7 |
| 13 | 1.4 | 0.5 | 0.9 |
| 14 | 1.7 | 0.6 | 1.1 |
| 16 | 2.7 | 0.8 | 1.3 |
| 18 | 3.7 | 1.0 | 1.8 |
| 21 | 6.2 | 1.4 | 2.4 |
| 24 | 9.3 | 1.9 | 3.0 |
| 30 | 18 | 2.9 | 4.6 |
| 36 | 33 | 4.2 | 6.7 |
| 42 | 52 | 5.7 | 9.0 |
| 48 | 74 | 7.5 | 12.0 |
| 63 | 168 | 13.0 | 20.0 |
*Cubic Ft. = 0.1337 x Gallons
Pressure Rating and Tapping
- CPVC
- Pressure Rating: 100 psi
- Tapping: As requested
- VE
- Pressure Rating: 150 psi
- Tapping: As shown only
Top and Bottom Opening Flanges/Manway
| Size | L | I.D. | B.C. | O.D. | A | Bolt Dia. | Number of Holes | Weight (lbs.) |
|---|---|---|---|---|---|---|---|---|
| 6" SNA | 3.6" | 5.9" | 8.5" | 9.4" | 0.31" | 12 | 5.8 | |
| 10" ANSI | 3.7" | 10.0" | 14.3" | 16.0" | 0.88" | 12 | 17.8 | |
| 16" Manway SNA | 4.3" | 16.0" | 20.4" | 21.3" | 0.50" | 24 | 34.0 |
Top and Bottom Opening Threads (Composite/Poly Glass)
- Minimum Full Threads: 3 min
- Thread Types:
- 2.5" - 8" NPSM: 6 full threads
- 4" - 8" UN: 7 full threads
- 4.5" - 8" Buttress: 7 full threads
Side Flange
| Size | L | I.D. | B.C. | O.D. | A | Bolt Dia. | Number of Holes | Weight (lbs.) |
|---|---|---|---|---|---|---|---|---|
| 4" ANSI | 4.1" | 4.0" | 7.5" | 9.0" | 0.63" | 8 | 6.4 |
Important Notes:
- Flexible connections must be installed between hard piping and tank openings. Failure to install flex connection properly with the vessel will void the warranty.
- These pressure vessels are treated for an internal negative pressure of 5y Hg (17 Pa) vacuum below atmospheric. If negative pressure could ever exceed 5y Hg (17 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.
- Measurements are subject to change without notice and are for reference only.
- Different base options can be selected on different tank diameters. The bases selected in the specifications illustrate most common base selections.
Disclaimer
This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions found in the complete OEM PDF datasheet. For contractual purposes, always refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.