Back to Pentair RO Membranes
Pentair logo

Datasheet summary

40846 Structural Composite Vessels

Engineering summary from PDF text extraction for 40846 Structural Composite Vessels. Verify every value with the OEM datasheet.

Summary

Product identification

These are Structural Composite Pressure Vessels, featuring reinforced fiberglass construction for water treatment and storage.

Product Features

  • For commercial and industrial water treatment and storage
  • 100% composite fiberglass construction
  • Outstanding performance and durability in harsh chemical environments
  • Absolutely will not – and cannot – rust
  • Requires little or no maintenance
  • Capacities up to 1600 gallons
  • Factory-backed five-year warranty
  • Commercial softening & filtration

Color Options

  • AL - Almond
  • BL - Blue
  • BK - Black
  • GR - Gray
  • NA - Natural

Specifications

Part No.DescriptionHeight w/base (inches/mm)Height w/o base (inches/mm)Capacity (Gallons/Liters)Cubic FeetBaseShip Weight (lbs.)
18" Dia.
CH3094818X65 COMP 4"T66.95 / 170165.07 / 166964 / 2428.56SMC67
CH3134318X65 COMP 4"T 4"B73.13 / 185865.6 / 139464 / 2428.56SMC EXT67
CH3169318X65 COMP 6"TF 6"BF84.12 / 213770.5 / 179162 / 2348.29SMC EXT92
21" Dia.
CH3095021X36 COMP 4"T41.7 / 105938.2 / 97045 / 1716.06SMC46
CH3157321X36 COMP 4"T 4"B47.5 / 120538.25 / 97045 / 1716.06SMC EXT53
CH3095321X62 COMP 4"T67.0 / 170263.4 / 161084 / 31811.23SMC95
CH3095421X62 COMP 4"T 4"B72.8 / 184863.5 / 161384 / 31811.23SMC EXT95
24" Dia.
CH3104324X38 COMP 4"T42.6 / 108138.5 / 97861 / 2318.15SMC65
CH3105324X50 COMP 4"T58 / 13052.9 / 134383.5 / 31611.16SMC90
CH3161124X50 COMP 4"T 4"B63 / 160152.9 / 134383.5 / 31611.16SMC EXT90
CH3204924X65 COMP 4"T65.2 / 165561.1 / 1552100 / 37813.36SMC109
CH3248124X65 COMP 4"T 4"B70.1 / 25760 / 1524100 / 37813.36SMC EXT115
CH3212924X65 COMP 6"TF65 / 165161.2 / 1556100 / 37813.36SMC114
CH3213924X65 COMP 6"TF 6"BF79 / 200765 / 1651100 / 37813.36TRIPOD114
CH3115324X72 COMP 4"T74.2 / 188470.12 / 1781118 / 45115.77SMC109
CH3115424X72 COMP 4"T 4"B80.4 / 204370.3 / 1786118 / 45115.77SMC EXT124
CH3115524X72 COMP 6"TF77 / 195673.4 / 1864118 / 45115.77SMC137
CH3115724X72 COMP 6"TF 6"BF88.5 / 224874.5 / 1892118 / 45115.77TRIPOD137
30" Dia.
CH3417730X60 COMP 6"TF71.6 / 181964.3 / 1634151 / 57220.2SMC EXT195
CH3417830X60 COMP 6"TF 6"BF82.5 / 209668.5 / 1740151 / 57220.2TRIPOD195
CH3365330X72 COMP 4"T77.2 / 196169.8 / 1772187 / 70824.99SMC EXT198
CH3116130X72 COMP 4"T 4"B77.2 / 196169.8 / 1772187 / 70824.99SMC EXT198
CH3116230X72 COMP 6"TF79.7 / 202569.9 / 1778187 / 70824.99SMC EXT195
CH31161330X72 COMP 6"TF 6"BF88.9 / 225874.9 / 1903187 / 70824.99SMC EXT211
36" Dia.
CH3120936X36 COMP 6"TBF55.3 / 140341 / 1041118 / 44715.8TRIPOD148
CH3141736X57 COMP 6"TF68 / 172759.3 / 1505205 / 77627.4SMC EXT225
CH3141836X57 COMP 6"TF 6"BF77.3 / 196263 / 1600205 / 77627.4TRIPOD225
CH3365236X72 COMP 4"T80.4 / 204271.8 / 1823264 / 99935.2SMC EXT264
CH3152336X72 COMP 4"T 4"B80.5 / 204570.5 / 1791264 / 99935.2SMC EXT285
CH3121436X72 COMP 6"TF83 / 210874.3 / 1886264 / 99935.2SMC EXT285
CH3121736X72 COMP 6"TF 6"BF90.4 / 229676.1 / 1934264 / 99935.2TRIPOD285
CH3171236X72 COMP 6"TF 6"BF 4"TBSF89.6 / 227575.3 / 1913264 / 99935.2TRIPOD292
42" Dia.
CH3127242X72 COMP 6"TF72.5 / 184271.1 / 1807345 / 130646.1SMC370
CH3127642X72 COMP 6"TF 6"BF90.1 / 228973 / 1854345 / 130646.1TRIPOD400
CH3422642X72 COMP 6"TF 6"BF 4"TBSF94.6 / 240377.5 / 1969345 / 130646.1TRIPOD415
48" Dia.
CH3128148X72 COMP 6"TF81.5 / 207175.2 / 1909463 / 175361.9SMC494
CH3128548X72 COMP 6"TF 6"BF92.9 / 236076.9 / 1953463 / 175361.9TRIPOD494
CH3128348X72 COMP 6"TF 6"BF 4"TBSF96.75 / 245880.75 / 2051463 / 175361.9TRIPOD504
63" Dia.
CH3139063X67 COMP 6"TF 6"BF81.4 / 206867.1 / 1704.3600 / 227180.2TRIPOD680
CH3132663X86 COMP 6"TF 6"BF98.5 / 250384.1 / 2136900 / 3407120.3TRIPOD950
CH3132763X86 COMP 16"TMWY 6"BF98.9 / 251384.5 / 2146900 / 3407120.3TRIPOD950
CH3129263X86 COMP 16"TMWY 6"BF 4"TBSF99 / 251585 / 2159900 / 3407120.3TRIPOD950
CH3423463X116 16"TMWY 6'BF 4"TBSF130.4 / 3312115.9 / 29451250 / 4732167TRIPOD1190
CH3160763X144 16"TMWY 6'BF 4"TBSF157.9 / 4012143.9 / 36561600 / 6057214TRIPOD1398

Material of Construction

  • Polyethylene inner shell

Operating limits

  • Maximum operating pressure: 150 psi
  • Maximum operating temperature:
    • 120°F (threaded)
    • 150°F (flanged)

Design Parameters

Pentair Design Parameters

  • Safety factor: 4:1
  • Minimum burst at 600 psi
  • Tested to 250,000 cycles without leakage

NSF Design Parameters

  • Safety factor: 4:1
  • Minimum burst at 600 psi
  • Tested to 100,000 cycles without leakage

ASME Design Parameters

  • Top/Bottom flange:
    • Safety factor: 5:1
    • Minimum burst at 750 psi
    • Tested to 33,000 cycles without leakage
  • Side flange:
    • Safety factor: 6:1
    • Minimum burst at 900 psi
    • Tested to 100,000 cycles without leakage

Installation Tips

  • Bolt base to floor
  • Calculate height for valve and base combined (see photo in official PDF)

Fleck Valve Adder Height

Tank Dia. (inches/mm)Adder Ht. (X) (inches/mm)
18/4576.5/165
21/5336.5/165
24,30/610,76212/305
315010/254
390015/381

Dome Volume (gallons) and Straight Wall Gallon per Inch

(Nominal Diameter)

D (inches)Gallons* (One Dome)Gallon/Inch (Approx.)A (Sq. Feet)
121.00.50.7
131.40.50.9
141.70.61.1
162.70.81.3
183.71.01.8
216.21.42.4
249.31.93.0
30182.94.6
36334.26.7
42525.79.0
48747.512.0
6316813.020.0

*Cubic Ft. = 0.1337 x Gallons

Pressure Rating and Tapping

  • CPVC
    • Pressure Rating: 100 psi
    • Tapping: As requested
  • VE
    • Pressure Rating: 150 psi
    • Tapping: As shown only

Top and Bottom Opening Flanges/Manway

SizeLI.D.B.C.O.D.ABolt Dia.Number of HolesWeight (lbs.)
6" SNA3.6"5.9"8.5"9.4"0.31"125.8
10" ANSI3.7"10.0"14.3"16.0"0.88"1217.8
16" Manway SNA4.3"16.0"20.4"21.3"0.50"2434.0

Top and Bottom Opening Threads (Composite/Poly Glass)

  • Minimum Full Threads: 3 min
  • Thread Types:
    • 2.5" - 8" NPSM: 6 full threads
    • 4" - 8" UN: 7 full threads
    • 4.5" - 8" Buttress: 7 full threads

Side Flange

SizeLI.D.B.C.O.D.ABolt Dia.Number of HolesWeight (lbs.)
4" ANSI4.1"4.0"7.5"9.0"0.63"86.4

Important Notes:

  • Flexible connections must be installed between hard piping and tank openings. Failure to install flex connection properly with the vessel will void the warranty.
  • These pressure vessels are treated for an internal negative pressure of 5y Hg (17 Pa) vacuum below atmospheric. If negative pressure could ever exceed 5y Hg (17 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.
  • Measurements are subject to change without notice and are for reference only.
  • Different base options can be selected on different tank diameters. The bases selected in the specifications illustrate most common base selections.

Disclaimer

This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions found in the complete OEM PDF datasheet. For contractual purposes, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.