Summary

Product Identification

This document describes the PENTAIR RO-2600 5 STAGE RO SYSTEM WITH PUMP. The system incorporates a Thin Layer Composite membrane: TLC-75. The HRO Booster Pump Model is: 8015-014-011.

System Operating Limits

  • Pressure range: 1.4–6.9 bar
  • Temperature range: 4.4-37.7°C
  • Total dissolved solids: 2000 ppm
  • Maximum hardness: 171 mg/L*
  • Sulfide, iron and manganese: <0.1 ppm**
  • Chlorine in water supply: <2 ppm
  • pH limits: 3–11
  • Turbidity: 5 NTU Max

* If the hardness of your water is above 171 mg/L, lime scale will build up rapidly on the membrane inside of the RO membrane cartridge, making the system ineffective. ** A maximum total level of approximately 0.1 ppm sulfide, iron or manganese is permissible.

Product Water Characteristics

  • Daily product water rate***: 227 Lpd
  • TDS rejection: 90% @ 2 bar inlet

***Based on manufacturer’s internal testing.

Performance (Product water output at various inlet pressures):

  • 1.4 bar: 181 Lph
  • 2.8 bar: 166 Lph
  • 4.1 bar: 151 Lph
  • 5.5 bar: 113 Lph
  • 6.9 bar: 41 Lph

Electrical

HRO Booster Pump:

  • Voltage: 24 Vdc
  • Amps: 2.2
  • Motor: 24 Vdc permanent magnet motor, CE listed

Mechanical / Hydraulic

Overall system dimensions:

  • 45.7 x 20.3 x 45.7 cm

Tank dimensions:

  • 34.3 x 27.9 cm

Weights:

  • Weight (system): 10.4 kg
  • Tank weight full: 12.9 kg

Tank capacity:

  • Tank capacity max: 16.5 L
  • Tank air pressure empty: 0.34-0.48 bar

HRO Booster Pump:

  • Ports: ⅜ inch NPT-F
  • Bypass: 5.5 bar
  • Pump design: positive displacement diaphragm pump

System Components and Consumables

The RO-2600 system includes:

  • Sediment cartridge P5
  • Carbon block cartridge EPM 10
  • Granular activated carbon cartridge GAC 10
  • Inline cartridge GS-10 RO
  • RO membrane TLC-75

System consumables can also be purchased under the part number ROKIT5000.