Back to Pentair RO Membranes
Pentair logo

Datasheet summary

X-Flow-Compact-1-2

Engineering summary from PDF text extraction for X-Flow-Compact-1-2. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: X-FLOW COMPACT 1.2
  • Type: Ultrafiltration Membrane
  • Article Code: 7271KPC99R
  • Description: 3 Inch 8.0 mm Compact 1.2

Applications

  • Effluent treatment
  • Membrane bioreactor

Operating limits

  • Max. feed pressure: 1000 kPa
  • Max. permeate pressure: 1000 kPa
  • Max. transmembrane pressure: -20 ~ +500 kPa
  • Max. temperature: 40 °C

Mechanical / hydraulic

Element Specifications

  • Membrane diameter: 8.0 mm
  • Membrane area: 1.2 m²
  • Module diameter D0: 90 mm
  • Module length L0: 1000 mm (±1)
  • Feed connection D1/I1: 3 inch/30 mm
  • Permeate connection d0/d1: 26/19 mm
  • Permeate length I0: 75 mm
  • Permeate position I1: 66 mm (±1)

Weight Specifications

  • Dry weight of membrane element: ca. 2 kg [4 lbs]
  • Membrane element filled with water: ca. 5 kg [11 lbs]

Materials of Construction

  • Housing: PVC, drinking water quality
  • Potting: EP resin
  • Membrane: Polyvinylidene fluoride material, composite polyester woven/non-woven carrier

Process Characteristics (water, 20 °C)

  • Hydraulic membrane diameter: 8.0 mm
  • Crossflow flow rate: 10.0 x v m³/h (v in m/s)
  • Pressure-drop across module (laminar flow): 0.5 x L0 x v kPa (L0 in m)
  • Pressure-drop across module (turbulent flow): 2.1 x L0 x v¹·⁷⁵ kPa (L0 in m)

Membrane characteristics

  • Hydrophilic tubular polyvinylidene fluoride membrane cast on a composite polyester/polyolefine carrier
  • Structure: asymmetric
  • Mean pore size: 30 nm
  • High performance and very good anti-fouling behaviour
  • Caution: To avoid mechanical damage, do not subject the membrane module or element to sudden temperature changes, particularly decreases. Do not exceed 40 °C process temperature. Bring the module or element back to ambient operating temperature slowly (typical value 1 °C/min).

Cleaning Chemical Resistance

  • NaOCl (active chlorine): 500 ppm max.
  • H₂O₂: 1000 ppm max.
  • NaOH: pH ≤ 11
  • Nitric acid: pH ≥ 1
  • Phosphoric acid: pH ≥ 1
  • EDTA: pH ≤ 11
  • Citric acid
  • Enzymatic compounds
  • Recommended pH during cleaning/disinfection: between 1 and 11
  • Recommended max temperature during cleaning/disinfection: 40 °C
  • Sodium Hypochlorite (NaOCl) typical use: 200 ppm, at ≤ 40 °C
  • Sodium Hypochlorite (NaOCl) maximum: 500 ppm
  • Sodium Hypochlorite (NaOCl) cumulative: 250,000 ppm hours at 30 °C

General Solvent Resistance (Guidelines)

  • Acids, pH >2: + (Resistant)
  • Bases, pH <11: + (Resistant)
  • Organic esters, ketones, ethers: -- (Not recommended)
  • Aliphatic alcohols: ++ (Highly resistant)
  • Aliphatic hydrocarbons: ++ (Highly resistant)
  • Halogenated hydrocarbons: ++ (Highly resistant)
  • Aromatic hydrocarbons: + (Resistant)
  • Polar organic solvents: -- (Not recommended)
  • Oils: ++ (Highly resistant)

Storage

  • New membrane modules: Can be stored as supplied in a dry, normally ventilated place, away from sources of heat, ignition, and direct sunlight. Store between 0 and 40 °C. Do not subject to freezing temperatures.
  • After use: UF membranes need to be stored wet at all times.
  • Biological growth prevention: Treat wet membranes with a compatible biocide.
    • Short-term shutdowns: Daily flush with permeate quality water containing up to 2.0 ppm free available chlorine for 30 to 60 minutes.
    • Long-term storage: Clean membranes before disinfection. A 1% sodium metabisulfite solution can be used for disinfection.
  • In either post-use storage situation, modules should be stored hydraulically filled.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet