Summary

Product identification

The product is an X-FLOW COMPACT 5.1G - 5.2MM Ultrafiltration Membrane. Article Code: 7381KPB99RH

Element Specifications

  • Membrane:
    • Diameter: 5.2 mm
    • Area: 5.1 m²
    • Material: Hydrophilic tubular polyvinylidene fluoride (PVDF) cast on a polyester carrier
    • Structure: Asymmetric
    • Mean pore size: 30 nm
    • Characteristics: Developed for large-scale water purification, high performance, very good anti-fouling behavior, backflushable for efficient cleaning.
  • Module:
    • Module diameter D0: 90 mm
    • Module length L0: 3000 mm (±1)
    • Feed connection D1: 3 inch
    • Permeate connection d1: 1 inch
    • Permeate length I0: 80 mm
    • Permeate position I1: 66 mm (±1)
  • Weight:
    • Dry weight of membrane element: ca. 6 kg [14 lbs]
    • Membrane element filled with water: ca. 15 kg [35 lbs]
  • Materials of Construction:
    • Housing: Glass fibre reinforced epoxy, drinking water quality
    • Potting: EP resin
    • Membrane Carrier: Composite polyester woven/non-woven

Operating limits

  • Temperature:
    • Maximum process temperature: 70 °C
    • Operating temperature range: 20-70 °C
    • Cleaning/Disinfection pH and temperature: Keep pH between 1 and 11, do not exceed 40 °C.
  • Pressure:
    • Max. feed pressure:
      • 800 kPa at 20 °C
      • 650 kPa at 30 °C
      • 550 kPa at 40 °C
      • 450 kPa at 50 °C
      • 380 kPa at 60 °C
      • 300 kPa at 70 °C
    • Max. permeate pressure:
      • 650 kPa at 20 °C
      • 550 kPa at 30 °C
      • 450 kPa at 40 °C
      • 380 kPa at 50 °C
      • 300 kPa at 60 °C
      • 100 kPa at 70 °C
    • Max. transmembrane pressure (TMP):
      • -100 ~ +500 kPa (at 20, 30, 40 °C)
      • -50 ~ +500 kPa (at 50, 60 °C)
      • -40 ~ +500 kPa (at 70 °C)
      • Negative TMP correlates with backwash pressure.

Applications

  • Pre-treatment RO and NF
  • Surface water
  • Drinking and process water production
  • Recovery of sandfilter backwash water
  • Effluent treatment
  • Membrane bioreactor
  • Wastewater treatment
  • Treatment of oil-in-water emulsions

General Solvent Resistance

(Indications are guidelines only)

  • Acids, pH >2: +
  • Bases, pH <11: +
  • Organic esters, ketones, ethers: --
  • Aliphatic alcohols: ++
  • Aliphatic hydrocarbons: ++
  • Halogenated hydrocarbons: ++
  • Aromatic hydrocarbons: +
  • Polar organic solvents: --
  • Oils: ++
  • Sodium Hypochlorite:
    • Typical: 200 ppm, at ≤ 40 °C
    • Maximum: 500 ppm
    • Cumulative: 250,000 ppm hours at 30 °C

Cleaning Chemical Resistance

(Recommended to keep pH between 1 and 11 and not exceed 40 °C during cleaning/disinfection)

  • NaOCl (active chlorine): 500 ppm max.
  • H₂O₂: 1000 ppm max.
  • NaOH: pH ≤ 11
  • Nitric acid: pH ≥ 1
  • Phosphoric acid: pH ≥ 1
  • EDTA: pH ≤ 11
  • Citric acid
  • Enzymatic compounds

Mechanical / Hydraulic

  • Hydraulic membrane diameter: 5.2 mm
  • Crossflow flow rate (*): 8.3 x v [m³/h] (where v is superficial velocity in m/s)
  • Pressure-drop across module (laminar flow) (**): 1.2 x L0 x v [kPa] (where L0 is module length in m)
  • Pressure-drop across module (turbulent flow) (**): 3.6 x L0 x v^(1.75) [kPa]

Storage

  • New membrane modules: Store as supplied, in a dry, normally ventilated place, away from heat, ignition, and direct sunlight. Store between 0 and 40 °C. Do not subject to freezing temperatures.
  • Used UF membranes: Must be stored wet at all times.
    • To avoid biological growth: Treat with a compatible biocide.
    • Short-term shutdowns: Daily flush with permeate quality water containing up to 2.0 ppm free available chlorine for 30 to 60 minutes may be adequate.
    • Long-term storage: Clean membranes before disinfection. A 1% sodium metabisulfite solution can be used for disinfection.
    • In either situation, modules should be stored hydraulically filled.