X-Flow-R-100-MF

Engineering summary from PDF text extraction for X-Flow-R-100-MF. Verify every value with the OEM datasheet.

Summary

Product identification

This document describes the X-FLOW R-100 microfiltration membrane, a stainless steel module designed for the filtration and/or clarification of aqueous solutions and beverages such as wine, juice, or cider.

  • Product Line: R-100 MICROFILTRATION
  • Article Codes (Module Housing and Insert):
    • 1.5 MF: 1832BB422A
    • 3.0 MF: 1832BB622A
  • Module Naming: 6” R-100 MODULE RVS & R-100 INSERT RVS
  • Mode of operation: Feed and bleed in crossflow mode with regular backwash.

Operating limits

  • Max. system pressure:
    • 1000 kPa at 20 °C
    • 600 kPa at 65 °C
  • Max. trans-membrane pressure:
    • 300 kPa at 0-50 °C
    • 200 kPa at 50-65 °C
  • Max. backflush pressure:
    • 200 kPa at 0-30 °C
    • 150 kPa at 30-40 °C
    • 100 kPa at 40-65 °C
  • Max. temperature: 65 °C

Note: Final maximum operating limits are determined by the lowest values of the membrane and element pressure and temperature specifications. Do not exceed 65 °C process temperature. Bring the module or element back to ambient operating temperature slowly (typical value 2-3 °C/min) to avoid mechanical damage.

Mechanical / hydraulic

General Specifications

  • Module length L0: 1040 mm
  • Permeate port protrusion l1: 112 mm
  • Permeate port lateral recess l0: 125 mm

Insert Specifications

  • Membrane Diameter [mm]:
    • 1.5: Membrane area 9.3 m², Insert length L0 1022 mm, Insert outer diameter D0 160.6 mm
    • 3.0: Membrane area 5.0 m², Insert length L0 1022 mm, Insert outer diameter D0 160.6 mm

Connection Specifications

  • Feed side: Flange: DIN 2633, 150NW
  • Permeate side: Coupling: DIN 11851, 65 NW
  • Feed connector: DIN 2633 B: 150 NW
  • Thread, male: DIN11851 A: 65 * 1/6"

Materials of Construction

  • Housing: Stainless steel AISI 316/316L
  • Potting: Epoxy, food grade
  • O-ring: Viton or EPDM
  • Membrane: PES/PVP

Process Characteristics (Water, 20 °C)

  • Membrane Diameter [mm]:
    • 1.5: Crossflow flow rate 13.7 x v [m³/h], Pressure-drop across module at 1 m/s 14 kPa, Pressure-drop across module at 2 m/s 56 kPa
    • 3.0: Crossflow flow rate 14.8 x v [m³/h], Pressure-drop across module at 1 m/s 7 kPa, Pressure-drop across module at 2 m/s 24 kPa
    • Superficial velocity (v) in m/s

Storage

  • New membrane modules should be stored as supplied in a dry, normally ventilated place, away from sources of heat, ignition, and direct sunlight.
  • Storage temperature: Between 0 and 40 °C
  • Relative humidity: Between 20 and 80 %
  • Modules should not be subjected to any freezing temperatures.
  • After use, MF membranes can be dried and spontaneously re-wetted without wetting agents.
  • For wet membranes, to avoid biological growth during shutdowns or storage, treatment with a compatible biocide is recommended. The membrane is compatible with many common disinfecting agents or biocidal preservatives.
  • Short-term shutdowns: A daily flush with permeate quality water containing up to 2.0 ppm free available chlorine for 30 to 60 minutes may be adequate for bacteria control.
  • Long-term storage: Membranes should be cleaned before disinfection. A 1% sodium metabisulfite solution can be used for disinfection.

Backwash Recommendations

  • Backwash water should be free of particulates and of permeate quality or better.
  • Backwash pumps should preferably be made of non-corroding materials (e.g., plastic or stainless steel).
  • If compressed air is used, do not allow a two-phase air/water mixture to enter the element.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.