Back to Pentair RO Membranes
Pentair logo

Datasheet summary

X-Flow-RX300-0-9UFC

Engineering summary from PDF text extraction for X-Flow-RX300-0-9UFC. Verify every value with the OEM datasheet.

Summary

Product Identification

The X-flow RX-300 0.9UFC is an ultrafiltration pilot module designed for the production of process and potable water. Typical applications include the filtration of surface water, potable water, and WWTP effluent.

  • Product Name: X-flow RX-300 0.9UFC
  • Article Code: 1051BL895A
  • Mode of Operation: Feed-and-bleed with a minor crossflow, or dead-end mode with regular backwash (permeate only) and chemically enhanced backwash.

Materials of Construction

  • Housing: PSF
  • Potting: EP resin
  • Membrane: PES/PVP

Operating Limits

  • Max. System Pressure:
    • 800 kPa [116 psi] at 20 °C
    • 600 kPa [86 psi] at 40 °C
    • 400 kPa [58 psi] at 60 °C
  • Max. Transmembrane Pressure:
    • 300 kPa [43 psi] at 0-30 °C
    • 200 kPa [29 psi] at 30-60 °C
  • Max. Backflush Pressure:
    • 300 kPa [43 psi] at 0-30 °C
    • 150 kPa [21.5 psi] at 30-60 °C
  • Max. Temperature: 60 °C [140 °F]

Important Operating Notes:

  • Avoid sudden temperature changes, particularly decreases, to prevent mechanical damage.
  • Do not exceed 60 °C process temperature.
  • Bring the module or element back to ambient operating temperature slowly (typical value 1 °C/min).
  • Final maximum operating limits are determined by the lowest values of the membrane and element pressure and temperature specifications.

Mechanical / Hydraulic

  • Membrane diameter: 0.9 mm [35.4 mil]
  • Membrane area: 0.08 m² [0.86 ft²]
  • Element length L0: 300 mm [11.8 Inch]
  • Element outer diameter: 23.9 mm [0.94 Inch]

Process Characteristics (water 20 °C):

  • Membrane diameter: 0.9 mm [35.4 mil]
  • Flow rate (*): 0.27 x v [1.19 x v] m³/h/gpm (where v is superficial velocity in m/s [ft/s])
  • Pressure-drop across module at 1 m/s: 11 kPa [1.6 psi]
  • Pressure-drop across module at 2 m/s: 24 kPa [3.5 psi]

Backwash Considerations:

  • Backwash water should be free of particulates and be of permeate quality or better.
  • Backwash pumps should preferably be made of non-corroding materials (e.g., plastic or stainless steel).
  • If compressed air is used to pressurize backwash water, do not allow a two-phase air/water mixture to enter the element.

Storage and Preservation

  • New Modules: Can be stored as supplied in original packaging. Elements contain an aqueous preservation solution of glycerine (20wt%) and sodium metabisulfite (1wt%).
  • Storage Conditions: Dry, normally ventilated place, away from sources of heat, ignition, and direct sunlight. Store between 0 and 40 °C. Do not subject to freezing temperatures.
  • Shelf Life: Maximum of 6 months for unused modules in unopened packaging under correct storage conditions after transfer of ownership.
  • After Use: UF membrane modules must be stored wet at all times.
    • Short-term shutdowns (1–7 days): A daily backwash with UF permeate quality water for 30 seconds at 215 lmh should be adequate for bacteria control. Before shutdown, modules must be cleaned by a standard Chemical Enhanced Backwash (CEB).
    • Long-term storage (> 7 days): Clean membranes using a CEB before disinfection. A 0.5% sodium metabisulfite solution can be used for disinfection. In both short and long-term storage, modules should remain filled with storage solution.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.