Summary

Product identification

  • Model: 4040-ACM1-TSF (4" ACM RO Element Series)
  • Membrane Type: ACM Fully Aromatic Polyamide Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap, Filmtec Style Core Tube
  • Active Membrane Area: 85 ft² (7.9 m²)

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed water

Performance is based on the following test conditions:

  • NaCl Concentration: 2,000.0 ppm
  • Applied Pressure: 225.0 psi
  • Temperature: 25°C
  • Recovery: 15%
  • pH: 8.0
  • Operation Duration: 30 minutes

Product water

  • Permeate Flow: 1,900 GPD (7.0 m³/day)*
  • Average Salt Rejection: 98.50%
  • Minimum Salt Rejection: 99.50% Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.

Mechanical / hydraulic

  • Element Weight: 15 lbs (7 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 4.0 inches (101 mm)
  • Permeate Tube (C): 0.75 inches (19.1 mm)
  • Feed Spacer: 0.031" thick diamond spacer
  • Maximum Feed Flow: 20 GPM (4.5 m³/hr)

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.