Back to TriSep Membranes
MANN+HUMMEL logo

Datasheet summary

8040-ACM2-UWA

Engineering summary from PDF text extraction for 8040-ACM2-UWA. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: 8040-ACM2-UWA
  • Series: 8" ACM RO Element Series
  • Membrane Type: ACM Fully Aromatic Polyamide Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Active Membrane Area: 400 ft² (37.2m²)
  • Core Tube: TriSep Style Core Tube

Operating Limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 4.0
  • Maximum Turbidity: 1 NTU

Product Water

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Permeate Flow: 10,700 GPD (40.0 m³/day)
  • Average Salt Rejection: 98.50%
  • Minimum Salt Rejection: 99.50%

Note: Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.

Mechanical / Hydraulic

(Units in pounds and inches; units in parentheses in kilograms and millimeters)

  • Element Weight: 50 lbs (23 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.028" thick diamond spacer

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.