8040-ACM5-TSA

Engineering summary from PDF text extraction for 8040-ACM5-TSA. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Series: 8" ACM-LP Low Pressure RO Element Series
  • Model: 8040-ACM5-TSA
  • Membrane Type: ACM-LP Fully Aromatic Polyamide Low Pressure Advanced Composite
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Core Tube: TriSep Style Core Tube
  • Active Membrane Area: 365 ft² (33.5 m²)

Mechanical / Hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.031" thick diamond spacer

Operating Limits

  • Recommended Applied Pressure: 50 - 300 psi (3 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed Water

  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU

Product Water

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 150.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Permeate Flow: 11,900 GPD (45.0 m³/day)
  • Average Salt Rejection: 97.50%
  • Minimum Salt Rejection: 98.50%

Note: Permeate flow is clean water flux at standard conditions. Individual element's permeate flow may vary +/- 15%.