Back to TriSep Membranes
MANN+HUMMEL logo

Datasheet summary

8040-ACM5-TSAN

Engineering summary from PDF text extraction for 8040-ACM5-TSAN. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: 8" ACM-LP Low Pressure RO Element Series
  • Model: 8040-ACM5-TSAN
  • Membrane Type: ACM-LP Fully Aromatic Polyamide Low Pressure Advanced Composite
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Active Membrane Area: 365 ft² (33.5 m²)

Mechanical / hydraulic

  • Core Tube Style: TriSep Style
  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 millimeters)
  • Diameter (B): 7.9 inches (200 millimeters)
  • Permeate Tube (C): 1.50 inches (38.1 millimeters)
  • Feed Spacer: 0.031" thick diamond spacer

Operating limits

  • Recommended Applied Pressure: 50 - 300 psi (3 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU

Product water

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 150.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Permeate flow: 11,900 GPD (45.0 m³/day)
    • Note: Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection: 97.50%
  • Minimum Salt Rejection: 98.50%

Disclaimer: This summary is based solely on the extracted text and may not include all figures, footnotes, or the latest revisions from the OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.