Back to TriSep Membranes
MANN+HUMMEL logo

Datasheet summary

8040-TS83-TSA

Engineering summary from PDF text extraction for 8040-TS83-TSA. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: 8040-TS83-TSA
  • Series: 8" TS80 Nanofiltration Element Series
  • Membrane Type: ANM Aromatic Polyamide Advanced Nanofiltration Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Active Membrane Area: 365 ft² (33.5 m²)

Operating limits

  • Recommended Applied Pressure: 40 - 200 psi (3 - 14 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU

Feed water

Performance is based on the following test conditions:

  • 2,000.0 ppm MgSO₄
  • 110.0 psi
  • 25°C
  • 15% recovery
  • pH 8.0
  • 30 minutes operation

Product water

  • Permeate flow (8040-TS83-TSA): 10,000 GPD (37.0 m³/day)
    • Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection (8040-TS83-TSA): 98.50%
  • Minimum Salt Rejection (8040-TS83-TSA): 97.00%

Mechanical / hydraulic

  • Element Weight: 45 pounds (20 kilograms)
  • Length (A): 40.0 inches (1,016 millimeters)
  • Diameter (B): 7.9 inches (200 millimeters)
  • Permeate Tube (C): 1.50 inches (38.1 millimeters)
  • Feed Spacer: 0.031" thick diamond spacer
  • Mechanical Configuration: TriSep Style Core Tube

Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the official OEM PDF revision used on your project.