Datasheet summary
8040-TS83-UWA
Engineering summary from PDF text extraction for 8040-TS83-UWA. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Series: 8" TS80 Nanofiltration Element Series
- Model: 8040-TS83-UWA
- Membrane Type: ANM Aromatic Polyamide Advanced Nanofiltration Membrane
- Configuration: Spiral Wound, Fiberglass Outer Wrap
- Active Membrane Area: 400 ft² (37.2 m²)
Operating limits
- Recommended Applied Pressure: 40 - 200 psi (3 - 14 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum Feed Flow: 80 GPM (18 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
Feed water
- Maximum SDI (15 minutes): 4.0
- Maximum Turbidity: 1 NTU
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
Product water
Performance is based on the following test conditions: 2,000.0 ppm MgSO₄, 110.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.
- Model 8040-TS83-UWA:
- Average Salt Rejection: 98.50%
- Minimum Salt Rejection: 97.00%
- Permeate Flow: 11,000 GPD (41.0 m³/day)*
* Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
Mechanical / hydraulic
- Core Tube: TriSep Style Core Tube
- Element Weight: 50 lbs (23 kg)
- Length (A): 40.0 inches (1,016 mm)
- Diameter (B): 7.9 inches (200 mm)
- Permeate Tube (C): 1.50 inches (38.1 mm)
- Feed Spacer: 0.028" thick diamond spacer
Disclaimer: This summary is generated from an extracted text segment and may not include all figures, footnotes, or the most recent revisions from the original OEM PDF datasheet. Contractual data should always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.