8040-X201-TSFA
Engineering summary from PDF text extraction for 8040-X201-TSFA. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: 8040-X201-TSFA
- Product Series: 8" X-20 Low Fouling RO Element Series
- Core Tube: Filmtec Style Core Tube
- Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
- Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
Operating Limits
- Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum Feed Flow: 80 GPM (18 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
Feed Water
- Maximum SDI (15 minutes): 5.0
- Maximum Turbidity: 2 NTU
Product Water
Performance is based on the following test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.
- Permeate Flow: 9,700 GPD (36.0 m³/day)*
- *Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
- Average Salt Rejection: 98.50%
- Minimum Salt Rejection: 99.50%
Mechanical / Hydraulic
- Element Weight: 45 lbs (20 kg)
- Length (A): 40.0 inches (1,016 mm)
- Diameter (B): 7.9 inches (200 mm)
- Permeate Tube (C): 1.12 inches (28.6 mm)
- Active Membrane Area: 365 ft² (33.5 m²)
- Feed Spacer: 0.031" thick diamond spacer
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data and complete specifications, the OEM PDF revision used on the project must be consulted.