Back to TriSep Membranes
MANN+HUMMEL logo

Datasheet summary

8040-X201-UWAN

Engineering summary from PDF text extraction for 8040-X201-UWAN. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: 8" X-20 Low Fouling RO Element Series
  • Model: 8040-X201-UWAN
  • Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
  • Active Membrane Area: 400 ft² (37.2 m²)
  • Core Tube: TriSep Style Core Tube

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed water

  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 2 NTU

Product water

  • Permeate Flow: 10,400 GPD (39.0 m³/day)*
    • *Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection: 98.50%
  • Minimum Salt Rejection: 99.50%

Performance Test Conditions:

  • 2,000.0 ppm NaCl
  • 225.0 psi
  • 25°C
  • 15% recovery
  • pH 8.0
  • 30 minutes operation

Mechanical / hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.028" thick diamond spacer

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.