8340-ACM2-TSQA

Engineering summary from PDF text extraction for 8340-ACM2-TSQA. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: 8.3" ACM RO Element Series
  • Membrane Type: ACM Fully Aromatic Polyamide Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Active Membrane Area: 415 ft² (38.1 m²)
  • Core Tube: Osmo Style

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Mechanical / hydraulic

  • Element Weight: 50 pounds (23 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 8.3 inches (210 mm)
  • Permeate Tube (C): 1.14 inches (29.0 mm)
  • Feed Spacer: 0.031" thick diamond spacer

Product water

The following performance is based on test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Model: 8340-ACM2-TSOA
    • Average Salt Rejection: 99.00%
    • Minimum Salt Rejection: 98.00%
    • Permeate Flow: 11,000 GPD (41.0 m³/day)

Note: Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.