Back to TriSep Membranes
MANN+HUMMEL logo

Datasheet summary

2540-UF10-QSF

Engineering summary from PDF text extraction for 2540-UF10-QSF. Verify every value with the OEM datasheet.

Summary

Product Identification

The TriSep X-20™ is a new generation, highly durable reverse osmosis (RO) membrane specifically designed for high fouling feed waters. It is a thin film composite membrane featuring a polyamide-urea copolymer barrier layer. The X-20 membrane surface has residual amino groups, which differ from traditional polyamide membranes' residual carboxylic acid groups, contributing to improved performance.

Available models and their nominal performance at standard test conditions:

  • 4040-X201-TSF
    • Permeate Flow: 2,000 GPD (7.6 m³/day)
    • Weight: 15 lbs (7 kg)
  • 8040-X201-TSA
    • Permeate Flow: 9,000 GPD (34 m³/day)
    • Weight: 45 lbs (20 kg)

Product Water

  • Average Salt Rejection: 99.5%
  • Minimum Salt Rejection: 98.5%

Operating Limits

  • Recommended Operating Pressure: 100 - 300 psi (0.7 - 2.1 MPa)
  • Maximum Applied Pressure: 600 psi (4.1 MPa)
  • Feedwater pH Range: 4 - 11 Continuous
  • Chlorine Tolerance: <0.1 ppm
  • Chloramine Tolerance: Up to 3 ppm continuous
  • Minimum Brine/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 2 NTU
  • Maximum Feed Flow:
    • 4040-X201-TSF: 20 GPM (4.5 m³/hr)
    • 8040-X201-TSA: 80 GPM (18 m³/hr)

Mechanical / Hydraulic

  • Membrane Type: X-20™ Polyamide-urea Thin Film Composite
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Length (A): 40.0 in. (1016 mm)
  • Diameter (B):
    • 4040-X201-TSF: 4.0 in. (102 mm)
    • 8040-X201-TSA: 7.9 in. (202 mm)
  • Permeate Tube (C): O.D. 0.75 in. (19.1 mm), I.D. 1.5 in. (38.1 mm)

Standard Test Conditions

Performance values are based on the following conditions:

  • 2000 ppm NaCl
  • 225 psi
  • 25°C
  • 15% recovery
  • pH 8
  • 30 minutes operation

Key Features

  • Low Fouling
  • Easy to Clean
  • Improved Silica Rejection
  • Resists up to 3 ppm of chloramine

Disclaimer: This summary is based on the provided text extract. The original OEM PDF may contain additional figures, footnotes, or more recent revisions. For contractual data, please refer to the specific OEM PDF revision used for your project.