Datasheet summary
HYDRAcap-MAX-80
PDF datasheet mirror for HYDRAcap-MAX-80 (Hydranautics UF Modules). Verify with OEM before design.
Summary
Product identification
- Product Name: HYDRAcap® MAX 80 Capillary Ultrafiltration Module
- Membrane Polymer: TIPS PVDF
- Nominal Membrane Area: 1130 ft² (105 m²)
- Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
- Pore size: 0.08 micron
- Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
- Certifications: NSF61, NSF419 (US LT2ESWTR – Public Drinking Water Compliance)
Operating limits
- Maximum Applied Feed Pressure:
- 73 psig (5.0 bar) at ≤20°C
- 58 psig (4 bar) between 21 - 30°C
- 44 psig (3 bar) between 31 – 40°C
- Maximum Transmembrane Pressure: 30 psig (2.0 bar)
- Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
- Maximum Chlorine Exposure: 1,000,000 ppm-hrs
- Maximum Operating Temperature: 104 F (40 C)
- pH Operating Range: 2.0 – 11.0
- Cleaning pH Range: 1.0 – 13.0
Feed water
- Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult Hydranautics’ technical staff)
Product water
- Filtrate Flow: 15.7 – 51.0 gpm (3.6 – 11.6 m³/h) (Typical module performance for most feedwaters)
- Filtrate Turbidity: ≤ 0.10 NTU
- Bacteria removal: ≥ 4 log
- Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)
Mechanical / hydraulic
- Module Dimensions:
- A: 92.15 inches (2340.6 mm)
- B: 83.11 inches (2110.9 mm)
- C: 87.90 inches (2232.7 mm)
- Pipe connections: 2” Victaulic
- Dry Weight: 135 lbs (62 kg)
- Wet Weight: 260 lbs (118 kg)
Cleaning and Disinfection
- Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
- Air Scour Duration: 120 – 240 seconds
- Air Scour Frequency: Once every 20 – 60 minutes
- Maintenance Clean Frequency: 1 – 3 times per day
- Maintenance Clean Duration: 20 – 30 minutes
- Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
- Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.