Back to Hydranautics UF Modules
Hydranautics logo

Datasheet summary

HYDRAcap-60

PDF datasheet mirror for HYDRAcap-60 (Hydranautics UF Modules). Verify with OEM before design.

Summary

Product identification

  • Type: Capillary Ultrafiltration Module
  • Model: HYDRAcap®60
  • Configuration: Capillary Ultrafiltration Module
  • Membrane Polymer: Hydrophilic Polyethersulfone
  • Nominal Membrane Area: 500 ft² (46 m²)
  • Fiber Dimensions: ID 0.031” (0.8 mm), OD 0.055” (1.4 mm)
  • Pore size: 0.02 micron
  • Operating Mode: Inside to Outside Filtration, Direct flow or Crossflow
  • Certifications: NSF61, CDPH, and ETV-NSF Verification

Product water

  • Filtrate Flow: 12.1 – 29.5 gpm (2.7 – 6.7 m³/h)
  • Filtrate Turbidity: ≤ 0.07 NTU
  • Virus removal: ≥ 4 log
  • Bacteria removal: ≥ 4 log

Operating limits

  • Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m²/h)
  • Maximum Applied Feed Pressure: 73 psig (5 bar) at 68°F (20°C)
  • Maximum Transmembrane Pressure: 20 psig (1.4 bar)
  • Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
  • Instantaneous Chlorine Tolerance: 100 ppm (for 15 minutes or less)
  • Instantaneous Hydrogen Peroxide Tolerance: 200 ppm (for 15 minutes or less)
  • Maximum Chlorine Exposure: 200,000 ppm-hrs
  • Maximum Instantaneous Feed Turbidity: 100 NTU
  • Maximum Operating Temperature: 104 F (40 C)
  • pH Operating Range: 4.0 - 10.0
  • Cleaning pH Range: 1.5 – 13.0

Feed water

  • Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
  • Backwash Duration: 30 – 60 seconds
  • Backwash Frequency: 20 – 60 minutes
  • Chemical Enhanced Backwash Frequency: 0 – 4 times per day
  • Chemical Enhanced Backwash Duration: 1 – 30 minutes
  • Disinfection Chemicals: NaOCl, H₂O₂, ClO₂, or NH₂Cl
  • Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid

Mechanical / hydraulic

  • Pipe connections: 2” Victaulic
  • Dry Weight: 80 lbs (36.3 kg)
  • Wet Weight: 155 lbs (70.3 kg)
  • Dimensions:
    • A: 63 inches (1600 mm)
    • B: 66 1/8 inches (1680 mm)
    • C: 67 1/4 inches (1708 mm)

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.