Back to Hydranautics UF Modules
Hydranautics logo

Datasheet summary

HYDRAcap-60-LD

PDF datasheet mirror for HYDRAcap-60-LD (Hydranautics UF Modules). Verify with OEM before design.

Summary

Product identification

  • Product Name: HYDRAcap®60-LD
  • Type: Capillary Ultrafiltration Module
  • Configuration: Capillary Ultrafiltration Module
  • Membrane Polymer: Hydrophilic Polyethersulfone
  • Pore size: 0.02 micron
  • Certifications: NSF61, CDPH, and ETV-NSF Verification

Performance

  • Filtrate Flow: 7.8 – 19 gpm (1.8 – 4.3 m³/h)
  • Filtrate Turbidity: ≤ 0.07 NTU
  • Virus removal: ≥ 4 log
  • Bacteria removal: ≥ 4 log

Operating limits

  • Maximum Applied Feed Pressure: 73 psig (5 bar) (at 68°F / 20°C)
  • Maximum Transmembrane Pressure: 20 psig (1.4 bar)
  • Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
  • Instantaneous Chlorine Tolerance: 100 ppm (for 15 minutes or less)
  • Instantaneous Hydrogen Peroxide Tolerance: 200 ppm (for 15 minutes or less)
  • Maximum Chlorine Exposure: 100,000 ppm-hrs
  • Maximum Instantaneous Feed Turbidity: 200 NTU
  • Maximum Operating Temperature: 104 F (40 C)
  • pH Operating Range: 4.0 - 10.0
  • Cleaning pH Range: 1.5 – 13.0

Mechanical / hydraulic

  • Nominal Membrane Area: 323 ft² (30 m²)
  • Fiber Dimensions: ID 0.047” (1.2 mm), OD 0.08” (2.0 mm)
  • Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m²/h)
  • Operating Mode: Inside to Outside Filtration, Direct flow or Crossflow
  • Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
  • Backwash Duration: 30 – 60 seconds
  • Backwash Frequency: 20 – 60 minutes
  • Chemical Enhanced Backwash Frequency: 0 – 4 times per day
  • Chemical Enhanced Backwash Duration: 1 – 30 minutes
  • Dimensions:
    • A: 63” (1600 mm)
    • B: 66 1/8” (1680 mm)
    • C: 67 1/4” (1708 mm)
  • Pipe connections: 2” Victaulic
  • Weight, ave.: 97 lbs. (44 kg) (shipping weight including 1L of a 0.95% solution of sodium bisulfite preservative)

Chemicals

  • Disinfection Chemicals: NaOCl, H₂O₂, ClO₂, or NH₂Cl
  • Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid