Datasheet summary
HYDRAcap-80
PDF datasheet mirror for HYDRAcap-80 (Hydranautics UF Modules). Verify with OEM before design.
Summary
Product identification
- Product Name: HYDRAcap80 Capillary Ultrafiltration Module
- Configuration: Capillary Ultrafiltration Module
- Membrane Polymer: Hydrophilic Polyethersulfone
- Nominal MWCO: 150,000 Daltons
- Nominal Membrane Area: 670 ft² (62.2 m²)
- Fiber Dimensions: ID 0.031” (0.8 mm), OD 0.055” (1.4 mm)
- Operating Mode: Inside to Outside Filtration, Direct flow or Crossflow
- Certifications: NSF61, CA-DHS and ETV-NSF Verification
Operating limits
- Maximum Applied Feed Pressure: 73 psig (5 bar)
- Maximum Transmembrane Pressure: 20 psig (1.4 bar)
- Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
- Instantaneous Chlorine Tolerance: 100 ppm (for 15 minutes or less)
- Instantaneous Hydrogen Peroxide Tolerance: 200 ppm (for 15 minutes or less)
- Maximum Chlorine Exposure: 100,000 ppm-hrs
- Maximum Operating Temperature: 104 °F (40 °C)
- pH Operating Range: 4.0 - 10.0
- Cleaning pH Range: 1.5 – 13.0
Feed water
- Maximum Instantaneous Feed Turbidity: 100 NTU
Product water
- Filtrate Flow: 16.3 – 39.5 gpm (3.7 – 9.0 m³/h)
- Filtrate Turbidity: ≤ 0.07 NTU
- Virus removal: ≥ 4 log
- Bacteria removal: ≥ 4 log
- Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m²/h)
Mechanical / hydraulic
- Dimensions (A, B, C):
- A: 83” (2108 mm)
- B: 86 1/8” (2188 mm)
- C: 87 1/4” (2216 mm)
- Note: Additional dimensions are provided in the official PDF diagram.
- Pipe connections: 2” Victaulic
- Weight (average shipping): 120 lbs (54 kg) (Includes 1L of a 0.95% sodium bisulfite preservative solution.)
Typical Process Conditions
- Backwash Flux: 100 – 150 gfd (170 – 255 l/m²/h)
- Backwash Duration: 30 – 60 seconds
- Backwash Frequency: 20 – 60 minutes
- Chemical Enhanced Backwash Frequency: 0 – 4 times per day
- Chemical Enhanced Backwash Duration: 1 – 30 minutes
- Disinfection Chemicals: NaOCl, H₂O₂, ClO₂ or NH₂Cl
- Cleaning Chemicals: HCl, H₂SO₄, NaOH or Citric Acid