Datasheet summary
HYDRAcap-MAX-40
PDF datasheet mirror for HYDRAcap-MAX-40 (Hydranautics UF Modules). Verify with OEM before design.
Summary
Product identification
- Product Name: HYDRAcap® MAX 40 Capillary Microfiltration Module
- Configuration: Capillary Microfiltration Module
- Membrane Polymer: PVDF
- Nominal Membrane Area: 560 ft² (52 m²)
- Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
- Pore size: 0.1 micron
- Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
Performance
- Filtrate Flow: 7.5 – 24.4 gpm (1.7 – 5.5 m³/h)
- Filtrate Turbidity: ≤ 0.10 NTU
- Bacteria removal: ≥ 4 log
- Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)
Operating limits
- Maximum Applied Feed Pressure: 73 psig (5.0 bar)
- Maximum Transmembrane Pressure: 30 psig (2.0 bar)
- Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
- Maximum Chlorine Exposure: 750,000 ppm-hrs
- Maximum Operating Temperature: 104 F (40 C)
- pH Operating Range: 4.0 – 10.0
- Cleaning pH Range: 1.0 – 13.0
Feed water
- Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult with Hydranautics’ technical staff.)
Mechanical / hydraulic
- Dimensions:
- A: 53.74 inches (1364.9 mm)
- B: 44.70 inches (1135.5 mm)
- C: 49.50 inches (1257.3 mm)
- Pipe connections: 2” Victaulic
- Dry Weight: 90 lbs (41 kg)
- Wet Weight: 161 lbs (73 kg)
Typical Process Conditions
- Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
- Air Scour Duration: 120 – 240 seconds
- Air Scour Frequency: Once every 20 – 60 minutes
- Maintenance Clean Frequency: 1 – 3 times per day
- Maintenance Clean Duration: 20 – 30 minutes
- Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
- Cleaning Chemicals: NaOCl, HCl, H₂SO₄, or Citric Acid
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.