Back to Hydranautics UF Modules
Hydranautics logo

Datasheet summary

HYDRAcap-MAX-60

PDF datasheet mirror for HYDRAcap-MAX-60 (Hydranautics UF Modules). Verify with OEM before design.

Summary

Product identification

  • Product Type: Capillary Microfiltration Module
  • Model: HYDRAcap® MAX 60
  • Membrane Polymer: PVDF
  • Nominal Membrane Area: 840 ft² (78 m²)
  • Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
  • Pore Size: 0.1 micron
  • Configuration: Capillary Microfiltration Module
  • Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode

Product water

  • Filtrate Flow: 11.7 – 37.9 gpm (2.7 – 8.6 m³/h)
  • Filtrate Turbidity: ≤ 0.10 NTU
  • Bacteria removal: ≥ 4 log
  • Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)

Operating limits

  • Maximum Applied Feed Pressure: 73 psig (5.0 bar)
  • Maximum Transmembrane Pressure: 30 psig (2.0 bar)
  • Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
  • Maximum Chlorine Exposure: 750,000 ppm-hrs
  • Maximum Operating Temperature: 104 F (40 C)
  • pH Operating Range: 4.0 – 10.0
  • Cleaning pH Range: 1.0 – 13.0

Feed water

  • Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult with Hydranautics’ technical staff.)

Mechanical / hydraulic

  • Dimensions:
    • A: 72.15 inches (1832.6 mm)
    • B: 63.11 inches (1602.9 mm)
    • C: 67.90 inches (1724.7 mm)
  • Pipe connections: 2” Victaulic
  • Dry Weight: 115 lbs (52 kg)
  • Wet Weight: 220 lbs (100 kg)

Typical Process Conditions

  • Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
  • Air Scour Duration: 120 – 240 seconds
  • Air Scour Frequency: Once every 20 – 60 minutes
  • Maintenance Clean Frequency: 1 – 3 times per day
  • Maintenance Clean Duration: 20 – 30 minutes
  • Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
  • Cleaning Chemicals: NaOCl, HCl, H₂SO₄ or Citric Acid

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.