Datasheet summary
Dizzer XL 0.9 MB 60 W
PDF datasheet mirror for Dizzer XL 0.9 MB 60 W (Inge (DuPont) Ultrafiltration). Verify with OEM before design.
Summary
Product identification
The dizzer® XL series consists of Ultrafiltration modules featuring Multibore® membranes.
Available Models (Multibore® 0.9 membrane):
- dizzer® XL 0.9 MB 60 W
- Part number: VK-0068
- Membrane area: 60 m² (645 sq.ft.)
- dizzer® XL 0.9 MB 38 W
- Part number: VK-0070
- Membrane area: 38 m² (410 sq.ft.)
Available Models (Multibore® 1.5 membrane):
- dizzer® XL 1.5 MB 40 W
- Part number: VK-0069
- Membrame area: 40 m² (430 sq.ft.)
- dizzer® XL 1.5 MB 25 W
- Part number: VK-0071
- Membrane area: 25 m² (270 sq.ft.)
Membrane Data (Multibore® 0.9 and 1.5 membranes):
- Pore size: approx. 0.02 µm
- Material: PESM
- Capillaries per fibre: 7
Specific Membrane Dimensions:
- Multibore® 0.9 membrane:
- Inner diameter: 0.9 mm
- Outer diameter: 4.0 mm
- Multibore® 1.5 membrane:
- Inner diameter: 1.5 mm
- Outer diameter: 6.0 mm
Mechanical / hydraulic
Module Materials:
- Housing: PVC-U, white
- End cap: PVC-U, grey
- End cap coupling: SS (sealing EPDM)
Module Dimensions and Weight (dizzer® XL 0.9 MB 60 W and dizzer® XL 1.5 MB 40 W):
- Length with end cap (L): 1680 ± 3 mm (66 1/8 inch)
- Length without end cap (L1): 1486 ± 1.5 mm (58 1/2 inch)
- Distance feed connectors (L2): 1600 ± 3 mm (63 inch)
- Distance feed – module center axis (A): 165 mm (6 1/2 inch)
- Distance feed – filtrate connector (B): 190 ± 1.5 mm (7 1/2 inch)
- Outer diameter end cap coupling max. (C): 295 mm (11 5/8 inch)
- Outer diameter module (D): 250 mm (9 7/8 inch)
- Connector flexible victaulic (d1): 2 inch
- Weight* (wet): 55 kg (120 lbs.)
- *shipping weight
Module Dimensions and Weight (dizzer® XL 0.9 MB 38 W):
- Length with end cap (L): 1180 ± 3 mm (46 1/2 inch)
- Length without end cap (L1): 986 ± 1.5 mm (38 3/4 inch)
- Distance feed connectors (L2): 1100 ± 3 mm (43 1/2 inch)
- Distance feed – module center axis (A): 165 mm (6 1/2 inch)
- Distance feed – filtrate connector (B): 190 ± 1.5 mm (7 1/2 inch)
- Outer diameter end cap coupling max. (C): 295 mm (11 5/8 inch)
- Outer diameter module (D): 250 mm (9 7/8 inch)
- Connector flexible victaulic (d1): 2 inch
- Weight* (wet): 40 kg (90 lbs.)
- *shipping weight
Module Dimensions and Weight (dizzer® XL 1.5 MB 25 W):
- Length with end cap (L): 1180 ± 3 mm (46 1/2 inch)
- Length without end cap (L1): 986 ± 1.5 mm (38 3/4 inch)
- Distance feed connectors (L2): 1100 ± 3 mm (43 1/3 inch)
- Distance feed – module center axis (A): 165 mm (6 1/2 inch)
- Distance feed – filtrate connector (B): 190 ± 1.5 mm (7 1/2 inch)
- Outer diameter end cap coupling max. (C): 295 mm (11 5/8 inch)
- Outer diameter module (D): 250 mm (9 7/8 inch)
- Connector flexible victaulic (d1): 2 inch
- Weight* (wet): 40 kg (90 lbs.)
- *shipping weight
Operating limits
- Pressure max.: 5 bar (73 psi)
- Temperature range: 1 – 40 °C (34 – 104 °F)
Transmembrane Pressure (TMP):
- Filtration*: 0.1 – 1.5 bar (1.5 – 20 psi)
- Backwash standard*: 0.3 – 3.0 bar (5 – 40 psi)
- Burst pressure membrane: > 10 bar (> 150 psi)
- *Specifications apply to common operating conditions.
Flux Rate:
- Filtration*: 60 – 180 l/(m²h) (35 – 105 gfd)
- Backwash standard: 230 l/(m²h) (135 gfd)
- Backwash range: 230 – 300 l/(m²h) (135 – 175 gfd)
- *Specifications apply to common operating conditions.
Cleaning and Disinfection
Cleaning/Disinfection Chemicals (Multibore® 0.9 and 1.5 membrane):
- Free chlorine:
- max. 200 ppm
- max. 200,000 ppm x h (at pH ≥ 9.5)
- H₂O₂ (Hydrogen peroxide): max. 500 ppm
- Caustic Soda pH: max. 13
- Acid pH: min. 1
Disclaimer This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.