Datasheet summary
T-Rack vario 2 /4 rows
PDF datasheet mirror for T-Rack vario 2 /4 rows (Inge (DuPont) Ultrafiltration). Verify with OEM before design.
Summary
Product Identification
The T-Rack® vario is an integrated module and rack design for ultrafiltration, featuring a compact footprint and flexible operation. It is available in configurations with either two or four rows of dizzer® modules.
- Smallest T-Rack® unit: 4 dizzer® modules in two rows.
- Largest T-Rack® unit: TR-80-4-V model with 80 modules in a four-row arrangement.
- Module types:
- dizzer® XL 0.9 MB 60 WT (Part number: VK-1068)
- dizzer® XL 1.5 MB 40 WT (Part number: VK-1069)
- Membrane type: Multibore® 0.9 and Multibore® 1.5.
Multibore® Membrane Data
| Parameter | Multibore® 0.9 | Multibore® 1.5 |
|---|---|---|
| Capillaries per fibre | 7 | 7 |
| Inner diameter | 0.9 mm | 1.5 mm |
| Outer diameter | 4.0 mm | 6.0 mm |
| Pore size | approx. 0.02 µm | approx. 0.02 µm |
| Material | PESM | PESM |
dizzer® XL Module Data
| Parameter | dizzer® XL 0.9 MB 60 WT | dizzer® XL 1.5 MB 40 WT |
|---|---|---|
| Membrane area | 60 m² (645 sq.ft.) | 40 m² (430 sq.ft.) |
| Length without end cap | 1486 ± 1.5 mm (58 1/2 inch) | 1486 ± 1.5 mm (58 1/2 inch) |
| Outer diameter of module | 250 mm (9 7/8 inch) | 250 mm (9 7/8 inch) |
| Weight (wet) | 48 kg (105 lbs.) | 42 kg (95 lbs.) |
| Material, Housing | PVC-U, white | PVC-U, white |
Operating Limits
- Temperature range: 1 – 40 °C (34 – 104 °F)
- Max. operating pressure T-Rack®:
- ≤ 20 °C (≤ 68 °F): 5 bar (70 psi)
-
20 °C (> 68 °F): 3 bar (42 psi)
- Flux rate:
- Filtration: 60 – 180 lmh (35 – 105 gfd)
- Backwash standard: 230 lmh (135 gfd)
- Backwash range: 230 – 300 lmh (135 – 175 gfd)
- Transmembrane pressure (TMP):
- Filtration: 0.1 – 1.5 bar (1.5 – 20 psi)
- Backwash standard: 0.3 – 3.0 bar (5 – 40 psi)
- Burst pressure membrane: > 10 bar (> 150 psi)
Cleaning/Disinfection Chemicals
- Free chlorine: max. 200 ppm; max. 200,000 ppm x h (at pH ≥ 9.5)
- H₂O₂ (Hydrogen peroxide): max. 500 ppm
- Caustic Soda pH: max. 13
- Acid pH: min. 1
Mechanical / Hydraulic
The T-Rack® vario design integrates feed and drain pipes into module end caps, uses 100% PVC header pipes, and allows each row to operate as a separate filtration line. Dummy modules can be used for capacity expansion.
Dimensions and Weights
- Header feed / drain:
- Inner diameter (di): 143 mm (5.59 inch)
- Outer diameter (da): 160 mm (6.30 inch)
- Header filtrate:
- Inner diameter (di): 143 mm (5.59 inch)
- Outer diameter (da): 160 mm (6.30 inch)
- Height (C) (all configurations):
- min: 2340 mm (7.68 ft.)
- max: 2400 mm (7.87 ft.)
- Width (B):
- 2-row configuration: 710 mm (2.33 ft.)
- 4-row configuration: 1420 mm (4.66 ft.)
Detailed tables for specific T-Rack® vario units, including length, membrane area, dry and filled weights, and hold-up volumes for both 2-row (4 to 40 modules) and 4-row (16 to 80 modules) configurations, are available in the official PDF datasheet.
Material of Construction
Key components and their materials include:
- Bottom cross brace: SS 1.4301 / AISI: 304, PE, PA6 GF30
- Top cross brace: SS 1.4301 / AISI: 304, PE
- dizzer® XL-W module body: PVC-U
- Module connecting parts: 1.4509 / AISI: 441, PA6 GF30, EPDM, PVC-U, PP
- Feed/drain header: PVC-U (with fixed flange according to ISO 7005 PN10, ANSI class 150)
- Filtrate header: PVC-U (160 mm, with fixed flange according to ISO 7005 PN10, ANSI class 150)