Datasheet summary
RX-300 0.83UFC
PDF datasheet mirror for RX-300 0.83UFC (Pentair X-Flow Modules). Verify with OEM before design.
Summary
Product identification
The X-FLOW RX300 0.83UFC is an ultrafiltration pilot module, used for the production of process and potable water.
- Article Code: 1051BL895A
- Typical Applications: Filtration of surface water, potable water, and WWTP effluent.
- Mode of Operation: Feed-and-bleed with a minor crossflow, or dead-end mode with regular backwash (permeate only) and chemically enhanced backwash.
Materials of Construction
- Housing: PSF
- Potting: EP resin
- Membrane: PES/PVP
Mechanical / hydraulic
Element Specifications
- Membrane diameter: 0.83 mm [32.7 mil]
- Membrane area: 0.08 m² [0.86 ft²]
- Element length L0: 300 mm [11.8 Inch]
- Element outer diameter: 23.9 mm [0.94 Inch]
Membrane Characteristics (Water 20 °C)
- Membrane diameter: 0.83 mm [32.7 mil]
- Flow rate (*): 0.27 x v [1.19 x v] (where v is superficial velocity in m/s [ft/s])
- Pressure-drop across module at 1 m/s: 11 kPa [1.6 psi]
- Pressure-drop across module at 2 m/s: 24 kPa [3.5 psi]
Operating limits
- Max. system pressure:
- at 20 °C: 800 kPa [116 psi]
- at 40 °C: 600 kPa [86 psi]
- at 60 °C: 400 kPa [58 psi]
- Max. transmembrane pressure:
- at 0-30 °C: 300 kPa [43 psi]
- at 30-60 °C: 200 kPa [29 psi]
- Max. backflush pressure:
- at 0-30 °C: 300 kPa [43 psi]
- at 30-60 °C: 150 kPa [21.5 psi]
- Max. temperature: 60 °C [140 °F]
Process Characteristics (Water 20 °C) Guidelines:
- To avoid mechanical damage, do not subject the membrane module or element to sudden temperature changes, particularly decreasing temperatures.
- Do not exceed 60 °C process temperature.
- Bring the module or element back to ambient operating temperature slowly (typical value 1 °C/min). Failure to adhere to this guideline can result in irreparable damage.
- Final maximum operating limits are determined by the lowest values of the membrane and element pressure and temperature specifications.
Product water
- Backwash water should be free of particulates and should be of permeate quality or better.
- Backwash pumps should preferably be made of non-corroding materials, e.g., plastic or stainless steel.
- If compressed air is used to pressurize the backwash water, do not allow a two-phase air/water mixture to enter the element.
Storage
- New membrane modules: Can be stored as supplied in the original packaging.
- Preservation solution: The membrane elements contain an aqueous preservation solution of glycerine (20wt%) and sodium metabisulfite (1wt%).
- Storage conditions: Dry, normally ventilated place, away from sources of heat, ignition, and direct sunlight. Store between 0 and 40 °C.
- Freezing: Membrane modules should not be subjected to any freezing temperatures.
- Shelf life: A maximum of 6 months for unused modules in unopened packaging under correct storage conditions after transfer of ownership. After this period, all warrantees are null and void unless otherwise agreed in writing.
- After use: UF membrane modules need to be stored wet at all times.
- Short-term shutdowns (1 – 7 days): A daily backwash with UF permeate quality water for 30 seconds at 240 lmh should be adequate for bacteria control. Before the shutdown period, modules must be cleaned by a standard Chemical Enhanced Backwash (CEB).
- Long-term storage (> 7 days): Membranes should be disinfected after a CEB. A 0.5% sodium metabisulfite solution can be used for disinfection.
- In both short and long-term storage situations, the modules should remain filled with storage solution.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.