Flow measurement
77 models in this family, organized across 6 subfamilies. Representative models: Proline Cubemass C 300, Proline Cubemass C 500, Proline Promass A 100.

International brand dossier
Endress+Hauser supplies field instrumentation for flow, level, liquid analysis, pressure and temperature measurement.
Endress+Hauser supplies field instrumentation for flow, level, liquid analysis, pressure and temperature measurement. Its water-treatment portfolio supports process monitoring, dosing control and plant automation; compare the measuring principle, range, wetted materials, process connection and output interface first.
408
Models and series
5
Product families
41
Subfamilies
Quick Model Index
Search specifications and compare candidates with products from other brands in the same category.
Uses the displayed unit. Missing specifications, ranges and test conditions are excluded from scalar filters.
Showing 408 of 408 models
Compare 2–4 compatible models across brands. Your shortlist is saved on this device.
Proline Cubemass C 300
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") · Measuring range: 0 to 1000 kg/h (0 to 37 lb/min) · Connection: 1.4539 (904L); 1.4404 (316/316L)
The Proline Cubemass C 300 is a compact Coriolis flowmeter designed for measuring small flow rates in skids, test rigs, and robotics, suitable for high-pressure and...
Proline Cubemass C 500
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Cubemass C 500 is a compact Coriolis flowmeter designed for measuring the smallest flow rates in skids, test rigs, and industrial robotics.
Proline Promass A 100
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass A 100 is a compact Coriolis flowmeter designed for precise measurement of small liquid and gas quantities.
Proline Promass A 200
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") · Medium temperature range: -50 to 205 °C (-58 to 401 °F) · Ambient temperature range: -40 to 60 °C (-40 to +140 °F)
The Proline Promass A 200 is a loop-powered Coriolis flowmeter designed for accurate measurement of lowest flow rates in demanding applications.
Proline Promass A 300
Flow measurement › Coriolis flowmeters
Medium Temperature Range: -50 to 205 °C (-58 to 401 °F) · Ambient Temperature Range: -40 to 60 °C (-40 to +140 °F) · Nominal Diameter Range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
The Endress+Hauser Proline Promass A 300 is a compact Coriolis flowmeter designed for continuous process control of liquids and gases.
Proline Promass A 500
Flow measurement › Coriolis flowmeters
Medium temperature range: -50 to 205 °C (-58 to 401 °F) · Ambient temperature range: -40 to 60 °C (-40 to +140 °F) · Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
The Endress + Hauser Proline Promass A 500 is a compact Coriolis flowmeter designed for demanding applications, offering accurate measurement of liquids and gases at low...
Proline Promass E 100
Flow measurement › Coriolis flowmeters
Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302°F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
The Proline Promass E 100 is a mid-range Coriolis flowmeter designed for accurate liquid and gas measurement in standard applications with an ultra-compact transmitter.
Proline Promass E 200
Flow measurement › Coriolis flowmeters
Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Nominal diameter range: DN 8 to 50 (⅜ to 2")
The Endress + Hauser Proline Promass E 200 is a Coriolis flowmeter designed for accurate liquid and gas measurement in standard chemical industry applications, including...
Proline Promass E 300
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 80 (⅜ to 3") · Measuring range: 0 to 180 000 kg/h (0 to 6615 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302 °F)
The Endress + Hauser Proline Promass E 300 is a mid-range Coriolis flowmeter designed for accurate measurement of liquids and gases in standard applications.
Proline Promass E 500
Flow measurement › Coriolis flowmeters
Measuring range: 0 to 180,000 kg/h (0 to 6615 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
Proline Promass E 500 is a variable-speed drive product, best compared by power range, control mode, enclosure rating, and pump or fan duty.
Proline Promass F 100
Flow measurement › Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +240 °C (–58…+464 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
The Proline Promass F 100 is an ultra-compact Coriolis flowmeter designed for precise measurement of mass flow, density, and temperature.
Proline Promass F 200
Flow measurement › Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +205 °C (–58 to +401 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
The Proline Promass F 200 is a robust Coriolis flowmeter offering high measurement performance for liquids and gases across various applications.
Proline Promass F 300
Flow measurement › Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +240 °C (–58 to +464 °F) · Medium temperature range (High temp option): –50 to +350 °C (–58 to +662 °F)
The Proline Promass F 300 is a Coriolis flowmeter offering premium accuracy and robustness for mass and volume flow measurement.
Proline Promass F 500
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 250 (⅜ to 10") · Measuring range: 0 to 2 200 000 kg/h (0 to 80 840 lb/min) · Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
The Proline Promass F 500 is a high-accuracy Coriolis flowmeter for demanding liquid and gas applications, featuring integrated Heartbeat Technology for reliability.
Proline Promass G 100
Flow measurement › Coriolis flowmeters
Medium Temperature Range: –50 to +150 °C (–58 to +302 °F) · Ambient Temperature Range: –40 to +60 °C (–40 to +140 °F) · Optional Ambient Temperature Range: –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass G 100 is a compact Coriolis flowmeter designed for accurate measurement of liquids and gases in high-pressure applications.
Proline Promass H 100
Flow measurement › Coriolis flowmeters
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Nominal diameter range: DN 8 to 50 (³⁄₈ to 2") · Connection: Tantalum; 702 (UNS R60702)
The Proline Promass H 100 is a chemically resistant Coriolis flowmeter with an ultra-compact transmitter, designed for aggressive fluids in space-constrained applications.
Proline Promass H 300
Flow measurement › Coriolis flowmeters
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Nominal diameter range: DN 8 to 50 (³⁄₈ to 2") · Connection: Tantalum; 702 (UNS R60702)
The Proline Promass H 300 is a highly accurate, chemically resistant Coriolis flowmeter designed for aggressive fluids.
Proline Promass H 500
Flow measurement › Coriolis flowmeters
Connection: Tantalum; 702 (UNS R60702) · Nominal diameter: DN 8 to 50 (³⁄₈ to 2") · Mass flow (liquid): ±0.10 %
The Proline Promass H 500 is a remote version Coriolis flowmeter designed for aggressive fluids requiring highest corrosion resistance and accuracy.
Proline Promass I 100
Flow measurement › Coriolis flowmeters
Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
The Endress + Hauser Proline Promass I 100 is an ultra-compact Coriolis flowmeter designed for measuring liquids and gases with minimal pressure loss.
Proline Promass I 300
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass I 300 is a straight single-tube Coriolis flowmeter designed for accurate liquid and gas measurement with low pressure loss.
Proline Promass I 500
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass I 500 is a remote transmitter Coriolis flowmeter designed for measuring liquids and gases with low pressure loss and gentle fluid...
Proline Promass K 10
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 80 (⅜ to 3") · Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F)
The Endress + Hauser Proline Promass K 10 is a compact Coriolis mass flowmeter designed for cost-efficient measurement of liquids and gases.
Proline Promass O 100
Flow measurement › Coriolis flowmeters
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) · Highest degree of protection: IP69 · Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
The Proline Promass O 100 is a robust, ultra-compact Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications, suitable for offshore...
Proline Promass O 300
Flow measurement › Coriolis flowmeters
Medium temperature range: –40 to +205 °C (–40 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass O 300 is a robust Coriolis flowmeter designed for premium accuracy in liquids and gases at the highest process pressures, suitable...
Proline Promass O 500
Flow measurement › Coriolis flowmeters
Medium temperature range: –40 to +205 °C (–40 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Promass O 500 is a robust, remote-version Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications, including offshore...
Proline Promass P 100
Flow measurement › Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
The Endress + Hauser Proline Promass P 100 is a Coriolis flowmeter designed for sterile conditions in the life sciences industry.
Proline Promass P 300
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70,000 kg/h (0 to 2570 lb/min) · Connection: 1.4435 (316L); 1.4404 (316/316L)
The Endress + Hauser Proline Promass P 300 is a specialist Coriolis mass flow meter designed for sterile applications in the life sciences industry.
Proline Promass P 500
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Connection: 1.4435 (316L); 1.4404 (316/316L)
The Proline Promass P 500 is a specialist Coriolis flowmeter designed for sterile processes in the life sciences industry.
Proline Promass Q 300
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 25 to 250 (1 to 10") · Measuring range (Mass Flow): 0 to 2,400,000 kg/h (0 to 88183 lb/min) · Connection: 1.4404 (316/316L)
The Proline Promass Q 300 is a Coriolis flowmeter designed for challenging applications, including custody transfer and liquids with entrained gas.
Proline Promass Q 500
Flow measurement › Coriolis flowmeters
Connection: 1.4404 (316/316L) · Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
The Endress+Hauser Proline Promass Q 500 is a Coriolis flowmeter optimized for challenging custody transfer applications, including liquids with entrained gas using...
Proline Promass S 100
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Promass S 100 is a hygienic Coriolis flowmeter designed for food and beverage applications with a self-drainable single-tube system.
Proline Promass S 300
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70,000 kg/h (0 to 2570 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F)
The Endress + Hauser Proline Promass S 300 is a hygienic Coriolis flowmeter designed for demanding applications in the food and beverage industry.
Proline Promass S 500
Flow measurement › Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F)
The Proline Promass S 500 is a remote Coriolis flowmeter designed for hygienic applications in the food and beverage industry.
Proline Promass X 300
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +180 °C (–58 to +356 °F) · Measuring range: 0 to 4100 t/h (0 to 4520 tn. sh./h) · Nominal diameter range: DN 300 to 400 (12 to 16")
Product Name:Proline Promass X 300、Product Type:Coriolis flowmeter、Description:Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.
Proline Promass X 500
Flow measurement › Coriolis flowmeters
Medium temperature range: –50 to +180 °C (–58 to +356 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –60 to +60 °C (–76 to +140 °F)
This Proline Promass X 500 is a remote-mount Coriolis flowmeter designed for the highest flow rates and demanding on/offshore oil and gas applications.
Dosimag-5BH
Flow measurement › Electromagnetic flowmeters
Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Measuring range: 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) · Nominal diameter range: DN 4 (⁵⁄₃₂"), 8 (⁵⁄₁₆"), 15 (½"), 25 (1")
The Endress + Hauser Dosimag-5BH is an electromagnetic flowmeter designed for precise dosing and filling of conductive liquids in hygienic applications.
Dosimag-D5AB
Flow measurement › Electromagnetic flowmeters
Measuring range: 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) · Medium temperature range (Seal material EPDM): –20 to +130 °C (–4 to +266 °F) · Medium temperature range (Seal material Silicone): –20 to +130 °C (–4 to +266 °F)
The Endress+Hauser Dosimag-D5AB is an electromagnetic flowmeter designed for hygienic dosing and filling of conductive liquids in the Food & Beverage and Life Sciences...
Dosimass-8BE
Flow measurement › Electromagnetic flowmeters
Medium temperature range: –40 to +125 °C (–40 to +257 °F); 150 °C allowed for 1 h · Ambient temperature range: –20 to +60 °C (–4 to +140 °F) · Measuring range (Mass flow): 0 to 18 000 kg/h (0 to 660 lb/min)
The Endress+Hauser Dosimass-8BE is a compact Coriolis flow meter designed for filling and bottling applications, measuring mass flow, density, and temperature.
Magphant-DTI200
Flow measurement › Electromagnetic flowmeters
Measuring range: 0 to 56'550 m³/h · Medium temperature range: -20 to +120°C (-4 to +248°F) · Ambient temperature range: -20 to 60°C (-4 to 140°F)
The Endress + Hauser Magphant DTI200 is a compact, cost-effective electromagnetic flowmeter and limit switch designed for water applications in utilities.
Picomag-DMA
Flow measurement › Electromagnetic flowmeters
Medium temperature range: -10 to 70°C (+14 to +158 °F) · Ambient temperature range: -10 to 60 °C · Measuring range (Volume flow): up to 750 l/min
The Picomag-DMA is an electromagnetic flowmeter designed for conductive liquids in various industries, measuring volume flow, temperature, and conductivity.
Proline-Promag D 10
Flow measurement › Electromagnetic flowmeters
Medium temperature range (Liner material polyamide): 0 to +60°C (+32 to +140°F) · Ambient temperature range: -40 to 60°C (-40 to 140°F) · Measuring range: 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
The Proline Promag D 10 is a cost-effective electromagnetic flowmeter designed for basic water applications in installations with limited space and plastic piping.
Proline-Promag E 100
Flow measurement › Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Medium temperature range: –10 to +110 °C (+14 to +230 °F)
The Endress + Hauser Proline Promag E 100 is an economical magnetic flowmeter designed for basic applications in the chemical and process industry.
Proline-Promag H 10
Flow measurement › Electromagnetic flowmeters
Nominal diameter range: DN 2 to 150 (¹⁄₁₂ to 6") · Measuring range (Volume flow): 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F)
The Proline Promag H 10 is an electromagnetic flowmeter designed for basic hygienic applications in the food and beverage and life sciences industries.
Proline-Promag H 100
Flow measurement › Electromagnetic flowmeters
Nominal diameter range: DN 2 to 150 (¹⁄₁₂ to 6") · Measuring range: 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F)
This is an electromagnetic flowmeter designed for hygienic applications in the food, beverage, and life sciences industries.
Proline-Promag H 200
Flow measurement › Electromagnetic flowmeters
Measuring range: 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
This is an electromagnetic flowmeter designed for the measurement of smallest flow rates with genuine loop-powered technology.
Proline-Promag H 500
Flow measurement › Electromagnetic flowmeters
Medium temperature range: –20 to +150 °C (–4 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Measuring range: 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
The Proline Promag H 500 is an electromagnetic flowmeter designed for demanding hygienic applications in the food and beverage and life sciences industries.
Proline-Promag P 10
Flow measurement › Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) · Medium temperature range (Liner PFA): –20 to +150 °C (–4 to +302 °F) · Medium temperature range (Liner PTFE): –40 to +130 °C (–40 to +266 °F)
The Endress+Hauser Proline Promag P 10 is an electromagnetic flowmeter designed for basic process applications with corrosive liquids and high medium temperatures.
Proline-Promag P 100
Flow measurement › Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 to 44,000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Power supply: DC 20 to 30 V
The Endress + Hauser Proline Promag P 100 is an electromagnetic flowmeter designed for corrosive liquids and high medium temperatures.
Proline-Promag P 200
Flow measurement › Electromagnetic flowmeters
Measuring range: 4 dm³/min to 1100 m³/h (1 to 4850 gal/min) · Nominal diameter range: DN 15 to 200 (½ to 8") · Power supply: DC 18 to 35 V (for 4–20 mA HART with/without pulse/frequency/switch output)
The Proline Promag P 200 is an electromagnetic flowmeter designed for corrosive liquids and high temperatures, suitable for hazardous areas.
Proline-Promag P 300
Flow measurement › Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Power supply: DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
The Proline Promag P 300 is a high-temperature electromagnetic flowmeter designed for corrosive liquids in demanding chemical and process applications.
Proline-Promag P 500
Flow measurement › Electromagnetic flowmeters
Nominal diameter range: DN 15 to 600 (½ to 24") · Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): 1.4409 (CF3M) similar to 316L
The Proline Promag P 500 is a remote-version electromagnetic flowmeter designed for high-temperature and corrosive chemical process applications.
Proline-Promag W 10
Flow measurement › Electromagnetic flowmeters
Measuring range: 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1665 Mgal/d) · Ambient temperature range: -40 to +60 °C (-40 to +140 °F) · Nominal diameter range: DN 25 to 3000 (1 to 120")
This is an electromagnetic flowmeter designed for basic water and wastewater applications, featuring international drinking water approvals.
Proline-Promag W 300
Flow measurement › Electromagnetic flowmeters
Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L · Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
The Proline Promag W 300 is an electromagnetic flowmeter designed for demanding water and wastewater applications.
Proline-Promag W 400
Flow measurement › Electromagnetic flowmeters
Nominal diameter range: DN 25 to 3000 (1 to 120") · Measuring range: 0.5 m³/h to 263000 m³/h (2.5 gal/min to 1665 Mgal/d) · Medium temperature range (Liner material hard rubber): 0 to +80 °C (+32 to +176 °F)
This versatile standard flowmeter is designed for the water and wastewater industry, offering reliable measurement with no pressure loss and flexible engineering for...
Proline-Promag W 500
Flow measurement › Electromagnetic flowmeters
Ambient temperature range (Flange material carbon steel): –10 to +60 °C · Ambient temperature range (Flange material stainless steel): –40 to +60 °C · Nominal diameter range: DN 25 to 3000 (1 to 120")
The Proline Promag W 500 is an electromagnetic flowmeter specialized for demanding water and wastewater applications, available in a remote version with up to four I/Os.
Proline-Promag W 800
Flow measurement › Electromagnetic flowmeters
Medium temperature range (Liner material hard rubber): 0 to +70 °C (+32 to +158 °F) · Medium temperature range (Liner material polyurethane): –20 to +50 °C (–4 to +122 °F) · Medium temperature range (Liner material PTFE): -20 to 70°C (–4 to +158 °F)
This is a battery-powered electromagnetic flowmeter designed for water industry applications, featuring EN ISO 12944 corrosion protection and an intelligent...
Promag 55S
Flow measurement › Electromagnetic flowmeters
Measuring range: 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2650 gal/min) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Nominal diameter range: DN 15...600 (1/2"...24")
The Endress+Hauser Promag 55S is an electromagnetic flowmeter designed for abrasive, corrosive, and inhomogeneous fluids with integrated solids content diagnostics.
Proline Prosonic Flow E 100
Flow measurement › Ultrasonic flowmeters
Measuring range (Flow velocity): 0.025 to 5 m/s (0.02 to 16.4 ft/s) · Measuring range (Volume flow): 0 to 6360 dm³/min (0 to 1680 gal/min) · Medium temperature range: 0 to 150 °C (17.8 to 302 °F)
The Proline Prosonic Flow E 100 is an economical ultrasonic flowmeter with integrated temperature measurement for demineralized water applications.
Proline Prosonic Flow I 400
Flow measurement › Ultrasonic flowmeters
Medium temperature range: –40 to +80 °C (–40 to +176 °F) · Ambient temperature range: -20 to 60°C (-4 to 140°F) · Nominal diameter range: DN200 to 4000 (8 to 160")
The Endress + Hauser Proline Prosonic Flow I 400 is an insertion ultrasonic flowmeter designed for water and wastewater applications in large pipelines.
Proline Prosonic Flow W 400
Flow measurement › Ultrasonic flowmeters
Medium Temperature Range: –40 to +130 °C (–40 to +266 °F) · Ambient Temperature Range (Sensor): -40 to 130 °C for all sensor sizes (DN 15 to 4000) · Measuring Range: 0 to 15 m/s (0 to 50 ft/s)
The Endress + Hauser Proline Prosonic Flow W 400 is an ultrasonic clamp-on flowmeter designed for reliable and maintenance-free measurement of conductive and...
Promass U 500
Flow measurement › Ultrasonic flowmeters
Medium Temperature Range: 3 to 60°C (37.4 to 140°F) · Ambient Temperature Range: 5 to 40°C (41 to 104°F) · Measuring Range: 0 to 75 kg/h (0 to 165.3 lb/min)
The Endress + Hauser Promass U 500 is a Coriolis flowmeter designed for single-use biopharmaceutical applications, particularly in monoclonal antibody processes.
Prosonic Flow Clamp On 9P5B
Flow measurement › Ultrasonic flowmeters
Nominal diameter range: Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160") · Measuring range: 0 to 15 m/s (0 to 50 ft/s) · Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
This Prosonic Flow Clamp On 9P5B is an ultrasonic clamp-on flowmeter for various fluids in process industries, featuring a flexible mounting system that minimizes inlet...
Prosonic Flow Clamp On 91W
Flow measurement › Ultrasonic flowmeters
Ambient temperature range: -20 to +60 °C (-4 to +140 °F) · Nominal diameter range: Single channel, 1 or 2 paths: DN15 to 2000 (1/2 to 80") · Measuring range: 0.3 to 10 m/s (1 to 33 ft/s)
The Endress + Hauser Prosonic Flow 91W is a clamp-on ultrasonic flow meter for process water, salt water, and wastewater.
Prosonic Flow Clamp On 93TA1
Flow measurement › Ultrasonic flowmeters
Measuring range: 0....452'389 m³/h · Degree of protection: IP 40 · Max. process pressure: No limit
The Prosonic Flow Clamp On 93TA1 is a portable ultrasonic flowmeter designed for temporary monitoring and test measurements of liquid applications from outside the pipe.
Prosonic Flow E Heat 9EHB
Flow measurement › Ultrasonic flowmeters
Medium temperature range: 0 to 150 °C (17.8 to 302 °F) · Ambient temperature range: -20 to 60 °C (-4 to 140 °F) · Measuring range (velocity): 0.025 to 5 m/s (0.02 to 16.4 ft/s)
The Endress + Hauser Prosonic Flow E Heat 9EHB is an industrial ultrasonic heat flow sensor designed for enhanced energy management and custody transfer.
Prosonic Flow Inline 92F
Flow measurement › Ultrasonic flowmeters
Medium temperature range: -40 to +150 °C (-40 to +302 °F) · Medium temperature range (optional): -40 to +200 °C (-40 to +392 °F) · Ambient temperature range (compact): -40 to +60 °C (-40 to +140 °F)
The Prosonic Flow Inline 92F is an ultrasonic flowmeter designed for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industries.
Teqwave F
Flow measurement › Ultrasonic flowmeters
Medium temperature range: 0 to 100 °C (32 to 212 °F) · Ambient temperature range: 0 to 50°C (32 to 122°F) · Nominal diameter range: DN 8 (1/4“) to DN 25 (1“)
The Teqwave F is an inline ultrasonic concentration meter designed for real-time liquid analysis in pipes, offering flexible application definition and simultaneous...
Teqwave H
Flow measurement › Ultrasonic flowmeters
Process Temperature Range: 0 to 120°C (32 to 248 °F) · Ambient Temperature Range: 0 to 60 °C (32 to 140 °F) · Power Supply: DC 24V ±20%
Teqwave H is an online instrument or sensor product for water systems, best compared by measured parameter, range, mounting style, and signal interface.
Teqwave I
Flow measurement › Ultrasonic flowmeters
Process temperature range: 0 to 100 °C (32 to 212 °F) · Medium temperature range: 0 to 100 °C (32 to 212 °F) · Ambient temperature range: 0 to 50 °C (32 to 122 °F)
The Endress + Hauser Teqwave I is an insertion-type ultrasonic concentration meter designed for real-time liquid analysis in vessels and larger pipes.
Teqwave T
Flow measurement › Ultrasonic flowmeters
Medium temperature range: 0 to +100 °C (32 to +212 °F) · Ambient temperature range: 0 to 40 °C (32 to 122 °F) · Power supply: Lithium-ion battery, 2300 mAh capacity
The Endress+ Hauser Teqwave T is a portable ultrasonic concentration meter designed for in situ liquid analysis.
Flowphant-T-DTT31
Flow measurement › Thermal mass flowmeters
Medium temperature range: -20...+85°C (-4...+185°F) · Nominal diameter range: DN 25...1000 (1"...40") · Max. process pressure: 100 bar (1.740 psi)
The Endress + Hauser Flowphant T DTT31 is an intelligent insertion-style thermal flow switch for liquid applications, featuring practically no pressure loss.
Proline Prowirl D 200
Flow measurement › Vortex flowmeters
Nominal diameter range: DN 15 to 150 (½ to 6") · Face-to-face length: 65 mm (2.56 in) · Volume flow (liquid): ±0.75 %
The Endress + Hauser Proline Prowirl D 200 is a cost-effective vortex flowmeter available in compact or remote versions, suitable for basic applications and steam flow...
Proline Prowirl F 200
Flow measurement › Vortex flowmeters
Nominal diameter range: DN 15 to 300 (½ to 12") · Measuring range (Liquid): 0.2 to 2100 m³/h (0.15 to 1520 ft³/min) · Measuring range (Steam, gas): 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
The Proline Prowirl F 200 is a multivariable vortex flowmeter designed for reliable steam, gas, and liquid measurement, offering integrated temperature and pressure...
Proline Prowirl O 200
Flow measurement › Vortex flowmeters
Nominal diameter range: DN 15 to 300 (½ to 12") · Process connection: 1.4404/F316/F316L · Max. process pressure: PN 250, Class 1500, 40K
The Endress + Hauser Proline Prowirl O 200 is a vortex flowmeter designed for demanding gas and steam applications with high process pressure.
Proline Prowirl R 200
Flow measurement › Vortex flowmeters
Nominal diameter range: DN 25 to 250 (1 to 10") · Accuracy: Same accuracy down to Re 10,000 · Process connection: 1.4404/F316/F316L
The Endress + Hauser Proline Prowirl R 200 is a vortex flowmeter designed for low flows and energy management, featuring integrated pipe reduction.
IFLRUN
Flow measurement › Differential flow measurement
Medium temperature range: –40 °C to +180 °C · Pressure rating: 150 / 300 / 600 / 900 / 1,500 / 2,500 · Materials in contact with the medium: Low temperature carbon steel, stainless steel
The FLOWRUN is a modular gas metering system designed for industry-standard applications with low measurement uncertainty.
IFLSKID
Flow measurement › Differential flow measurement
Medium temperature range: –40 °C ... +180 °C · Pressure rating: 150 / 300 / 600 / 900 / 1,500 / 2,500 · FLOWSKID600-compact: ≤ 5
The Endress + Hauser FLOWSKID is a complete gas flow metering system designed for custody transfer applications.
Liquiphant Failsafe FTL80
Level measurement › Vibronic point level
Output signal: 4-20 mA interface (acc. to NAMUR NE 06/NE 43) · Status signals: LEDs indicate: Operation, Function check, Outside specification, Maintenance required, Failure, Power supply issues · Process temperatures: –60 to 280 °C (–76 to 536 °F)
The Liquiphant FailSafe FTL80 is a vibronic point level switch for minimum and maximum detection in liquids, suitable for highly corrosive media.
Liquiphant FTL41
Level measurement › Vibronic point level
Process temperature range: –40 to +150 °C (–40 to +302 °F) · Ambient temperature range: –40 to +70 °C (plastic housing limited to –20 °C) · Process pressure range: Up to 40 bar (580 psi) at 150 °C (dependent on the lowest-rated component, e.g., process connection)
This Endress + Hauser Liquiphant FTL41 is a vibronic point level switch for maximum or minimum detection in tanks, containers, and piping with all types of liquids.
Liquiphant FTL43
Level measurement › Vibronic point level
Process temperature range: –40 to +150 °C (–40 to +302 °F) · Process pressure range: Up to 64 bar (928 psi) · Process connections: Flange (ASME B16.5, EN1092-1), Thread (ISO228), Ingold, Flush-mounted tank connection, DIN11851, DIN11864-1, DRD, SMS1145, Varivent, Clamp/Tri-Clamp
The Liquiphant FTL43 is a point level switch for all pumpable liquids, ideal for hazardous areas and offering hygienic design certifications.
Liquiphant FTL51B
Level measurement › Vibronic point level
Density range: > 0.7 g/cm³ · Output signal: 4 to 20 mA HART · Measuring range: See official PDF for exact tabulated values
The Liquiphant FTL51B is a vibronic point level switch for liquids.
Liquiphant FTL62
Level measurement › Vibronic point level
Process Temperature Range: –50 to +150 °C (–58 to +302 °F) · Process Pressure Range: Up to 40 bar (580 psi) · Ambient Temperature Range: –40 to +70 °C (–40 to +158 °F)
The Liquiphant FTL62 is a point level switch designed for all liquids, offering reliable detection in tanks and piping, even in hazardous areas.
Liquiphant FTL63
Level measurement › Vibronic point level
Process temperature range: –50 to +150 °C (–58 to +302 °F) · Process pressure range: up to 64 bar (928 psi) · Ambient temperature range: –40 to +70 °C (–40 to +158 °F). Optional extended ranges down to –60 °C (–76 °F) with restricted operating life and performance
The Liquiphant FTL63 is a vibronic point level switch for detecting minimum or maximum levels in pumpable liquids across various applications.
Liquiphant FTL64
Level measurement › Vibronic point level
Process temperature range: –60 to +280 °C (–76 to +536 °F) · Pressure range: Up to 100 bar (1 450 psi) · Measuring range: Depends on installation location and ordered pipe extension. Standard pipe extension up to 3 m (9.8 ft); up to 6 m (20 ft) on request
The Endress+Hauser Liquiphant FTL64 is a vibronic point level switch for all liquids, designed for hazardous areas and high-temperature applications up to 280 °C.
Liquiphant M FTL50
Level measurement › Vibronic point level
Ambient Temperature Range: -50 °C to +150 °C (depending on housing and electronic insert) · Process Connections: Various options available, including hygienic connections for H models · Process Temperatures: –50 °C to 150 °C (–58 °F to 302 °F)
The Endress + Hauser Liquiphant M FTL50 is a vibronic point level switch designed for all types of liquids in tanks or pipes.
Liquiphant M FTL50H
Level measurement › Vibronic point level
Ambient Temperature Range: -50 °C to +150 °C (depending on electronic insert and housing) · Process Temperatures: –50 °C to 150 °C (–58 °F to 302 °F) · Pressures: Up to 100 bar (1450 psi)
The Endress+Hauser Liquiphant M FTL50H is a vibronic point level switch suitable for all liquid types in demanding applications.
Liquiphant M FTL51
Level measurement › Vibronic point level
Process connections: Flanges according to DIN/EN, ASME, JIS from DN 40 / 1½" · Ambient temperature range: Dependent on medium temperature. See official PDF for graph · Temperature: –50 °C to 150 °C (–58 °F to 302 °F)
The Liquiphant M FTL51C is a vibronic point level switch for detecting maximum or minimum levels in all types of liquids.
Liquiphant T FTL31
Level measurement › Vibronic point level
Process pressure range: Max. –1 to +40 bar (–14.5 to +580 psi) · Ambient temperature range: –40 to +70 °C (–40 to +158 °F) · Process Connections: Various threads available, including G ½", G ¾", G 1", MNPT ½", MNPT ¾", MNPT 1", R ½", R ¾", R 1". Weld-in adapters are also available
The Liquiphant FTL31 is a point level switch for liquids, designed for challenging applications where other sensors may fail.
Liquiphant T FTL33
Level measurement › Vibronic point level
Process pressure range: Max. –1 to +40 bar (–14.5 to +580 psi) · Ambient temperature range: –40 to +70 °C (–40 to +158 °F) · Process connection materials: 316L (1.4404/1.4435)
The Liquiphant T FTL33 is a vibronic point level switch for liquids, featuring robust stainless steel construction with EHEDG and 3-A certifications.
Liquipoint FTW23
Level measurement › Vibronic point level
Ambient Temperature Range: –20 to +70 °C (–4 to +158 °F) · Switching Accuracy: ±2 mm (0.08 in) · Connection Options: M12 connector (optional with IP69 protection)
The Endress + Hauser Liquipoint FTW23 is a capacitance point level switch suitable for water-based, alcohol-based, and oil-based liquids, or powdered products.
Liquipoint FTW33
Level measurement › Vibronic point level
Ambient temperature range: –40 to +70 °C (–40 to +158 °F) · Process temperature range: –20 to +100 °C (–4 to +212 °F); up to 150 °C (302 °F) for 1 hour · Process pressure range: –1 to +25 bar (–14.5 to +362.5 psi)
The Liquipoint FTW33 is a point level switch designed for hygienic applications in the food and beverage industry, suitable for liquids and pastes with a dielectric...
Nivotester FTL325N
Level measurement › Vibronic point level
Control Current Range: 2.1 mA · Connection Cable Cross Section: Maximum 2.5 mm² (single core) or 1.5 mm² (two core) · Measuring Sensor Power Supply: Supplied by the FTL 325 N Nivotester
The Nivotester FTL325N is an isolating amplifier for level limit detection in hazardous areas and liquid detection in pipes.
Nivotester FTL825
Level measurement › Vibronic point level
Measuring Range: 4 to 20 mA signal (discrete depending on operating mode) · Signal Transmission: 4 to 20 mA as per NAMUR NE 43 with additional LIVE signal · Power Supply: Provided by the Nivotester FailSafe FTL825
The Nivotester FailSafe FTL825 is a two-wire system point level switch designed for fail-safe liquid detection in safety systems up to SIL3.
Nivotester FTW325
Level measurement › Vibronic point level
Supply Voltage Connection: To lower, green terminal blocks. Built-in fuse (AC: T 250 mA / DC: 400 mA). Reverse polarity protection included · Connection Cross-section: 1 x 2.5 mm² (1 x 14 AWG) or 2 x 1.5 mm² (2 x 16 AWG) · Measuring Range: Dependent on probe mounting location
The Endress + Hauser Nivotester FTW325 is a conductive point level switch designed for overfill protection, dry run protection, and point level detection in hazardous...
Soliphant M FTM50
Level measurement › Vibronic point level
Ambient Temperature Range: –50 to +70 °C (–58 to +158 °F). Restricted to –40 to +70 °C (–40 to +158 °F) with F16 housing · Medium Temperature Range: Varies with ambient temperature and housing type. High-temperature versions allow process temperatures up to 280 °C (536 °F) with corresponding ambient temperature limits · Medium Pressure Range: –1 to +25 bar (–14.5 to +362.5 psi)
The Soliphant M FTM50 is a vibronic point level switch for fine-grained bulk solids, offering SIL2 functional safety and resistance to buildup.
Soliphant M FTM51
Level measurement › Vibronic point level
Process Temperature Range: Up to 280 °C (536 °F) · Medium Pressure Range: –1 to +25 bar (–14.5 to +362.5 psi) · Ambient Temperature Range: –50 to +70 °C (–58 to +158 °F) (–40 to +70 °C for F16 housing)
The Soliphant M FTM51 is a universal point level switch designed for fine-grained or dusty bulk solids, with options for potentially explosive atmospheres.
Soliphant M FTM52
Level measurement › Vibronic point level
Medium Temperature Range: Up to 280 °C (536 °F) · Medium Pressure Range: –1 to +25 bar (–14.5 to +362.5 psi) · Ambient Temperature Range: –50 to +70 °C (–58 to +158 °F); –40 to +70 °C (–40 to +158 °F) with F16 housing
The Soliphant M FTM52 is a universal point level switch for fine-grained bulk solids, utilizing a vibronic measuring principle.
Soliphant T FTM20
Level measurement › Vibronic point level
Measuring Range: Dependent on mounting location and selected pipe extension length (500 mm, 1000 mm, 1500 mm) · Ambient Temperature Range: –40 to +70 °C (–40 to +158 °F) · Limiting Medium Pressure Range: –1 to 25 bar (–14.5 to 362.5 psi)
The Endress+Hauser Soliphant T FTM20 is a vibronic point level switch designed for bulk solids, featuring a compact design and maintenance-free operation.
Micropilot FMR10
Level measurement › Radar level
Measuring range: up to 12 m (39.37 ft) (with 40 mm antenna and flooding protection tube accessory) · Ambient temperature range (device): –40 to +60 °C (–40 to +140 °F) · Output signal: 4 to 20 mA (analog)
The Micropilot FMR10 is a free space radar sensor for level measurement in liquids within storage tanks and open basins.
Micropilot FMR10B
Level measurement › Radar level
Ambient Temperature Range: –40 to +60 °C (–40 to +140 °F) · Maximum Measuring Range: 10 m (33 ft) · Output Signal: 4 to 20 mA
The Micropilot FMR10B is a free-space radar sensor for continuous, non-contact level measurement of liquids and bulk solids, and can also be used for flow measurement in...
Micropilot FMR20B
Level measurement › Radar level
Accuracy: Up to ± 2 mm (0.08 in) · Output signal: 4 to 20 mA with superimposed digital communication protocol HART, 2-wire · Antenna end process connection: PVDF
The Endress + Hauser Micropilot FMR20B is a free-space radar sensor for continuous, non-contact level measurement of liquids and bulk solids.
Micropilot FMR30B
Level measurement › Radar level
Maximum Measuring Range: Up to 30 m (98.4 ft) depending on antenna size and medium · Ambient Temperature Range: –40 to +80 °C (–40 to +176 °F) · Output Signal: 4 to 20 mA with superimposed digital communication protocol HART, 2-wire
This is a free-space radar level sensor for continuous, non-contact measurement of liquids and bulk solids, also capable of flow measurement in open channels.
Micropilot FMR43
Level measurement › Radar level
Maximum measuring range: 15 m (49 ft) · Accuracy: ±1 mm (±0.04 in) · Output signal: 4 to 20 mA with superimposed digital communication protocol HART, 2-wire
The Micropilot FMR43 is a free-space radar transmitter for continuous, non-contact level measurement in hygienic applications.
Micropilot M FMR20
Level measurement › Radar level
Maximum Measuring Range: up to 10 m (32.8 ft) · Measuring Range: Maximum 10 m (32.8 ft) · Ambient Temperature Range: –40 to +80 °C (–40 to +176 °F). Bluetooth® connection may be affected above 60 °C (140 °F)
The Micropilot FMR20 is a free space radar sensor designed for level measurement of bulk solids up to 10 meters.
Micropilot M FMR50
Level measurement › Radar level
Maximum measuring range: 40 m (131 ft) · Range under reference conditions: > 10 m (33 ft) · Accuracy: ± 2 mm
The Endress+Hauser Micropilot FMR50 is a non-contact radar level instrument for continuous measurement of liquids, pastes, and slurries.
Micropilot M FMR51
Level measurement › Radar level
Maximum measuring range: 70 m (230 ft) · Accuracy: ± 2 mm · Output signal: HART (FSK ±0.5 mA over current signal, 1200 Bit/s, galvanic isolation)
The Endress + Hauser Micropilot M FMR51 is a free space radar level sensor for continuous, non-contact measurement of liquids, pastes, and slurries.
Micropilot M FMR53
Level measurement › Radar level
Maximum measuring range: 20 m (66 ft); For FMR54 with planar antenna in a stilling well: 38 m (125 ft) · Range under reference conditions: > 10 m (33 ft) · Accuracy: ± 6 mm
The Micropilot M FMR53 is a free-space radar level sensor designed for continuous, non-contact measurement of liquids, pastes, and sludges, featuring a rod antenna.
Micropilot M FMR56
Level measurement › Radar level
Process Temperature: –40 to +400 °C (–40 to 752 °F) · Process Pressure: –1 to +16 bar (–14.5 to +232 psi) · Operating Frequency: K-band (~ 26 GHz)
The Micropilot M FMR56 is a free-space radar instrument for continuous, non-contact level measurement of bulk solids.
Micropilot M FMR60
Level measurement › Radar level
Maximum measuring range: 50 m (164 ft) · Ambient temperature range (Measuring device): –40 to +80 °C (–40 to +176 °F) · Ambient temperature range (Local display): –20 to +70 °C (–4 to +158 °F)
The Micropilot FMR60 is a free space radar instrument for continuous, non-contact liquid, paste, and sludge level measurement.
Micropilot M FMR60B
Level measurement › Radar level
Maximum measuring range: 50 m (164 ft) · Temperature range (process): –40 to +200 °C (–40 to +392 °F) · Pressure range (process): –1 to +20 bar (–14.5 to +290 psi)
The Micropilot M FMR60B is a free-space radar transmitter for continuous, non-contact level measurement of liquids, pastes, and sludges.
Micropilot M FMR62
Level measurement › Radar level
Maximum measuring range: 80 m (262 ft) · Temperature range: –40 to +200 °C (–40 to +392 °F) · Pressure range: –1 to +25 bar (–14.5 to +362.6 psi)
The Endress+Hauser Micropilot FMR62 is a free-space radar level measuring instrument for continuous, non-contact level measurement of liquids, pastes, and sludges.
Micropilot M FMR62B
Level measurement › Radar level
Maximum measuring range: 80 m (262 ft) · Accuracy: ±1 mm (±0.04 in) · Output signal: HART (FSK ±0.5 mA over current signal, 1200 Bit/s)
The Endress + Hauser Micropilot FMR62B is a free-space radar instrument for continuous, non-contact level measurement of liquids, pastes, and sludges.
Micropilot M FMR63B
Level measurement › Radar level
Maximum measuring range: 80 m (262 ft) · Temperature range: –40 to +200 °C (–40 to +392 °F) · Pressure range: –1 to +25 bar (–14.5 to +363 psi)
The Endress+Hauser Micropilot FMR63B is a free-space radar level instrument designed for hygienic applications with continuous, non-contact liquid measurement.
Micropilot M FMR66B
Level measurement › Radar level
Maximum measuring range: 50 m (164 ft) · Process temperature range: –40 to +130 °C (–40 to +266 °F) · Process pressure range: –1 to +16 bar (–14.5 to +232 psi)
The Micropilot FMR66B is a free-space radar level sensor designed for continuous, non-contact measurement of powdered to granular bulk solids.
Micropilot M FMR67
Level measurement › Radar level
Maximum Measuring Range: 125 m (410 ft) · Temperature Range: –40 to +200 °C (–40 to +392 °F) · Pressure Range: –1 to +16 bar (–14.5 to +232 psi)
The Endress+Hauser Micropilot M FMR67 is a free space radar sensor for continuous, non-contact level measurement of bulk solids.
Micropilot M FMR67B
Level measurement › Radar level
Maximum Measuring Range: 125 m (410 ft) · Process Temperature Range: –40 to +450 °C (–40 to +842 °F) - Note: Ambient temperature limits vary based on housing material and process temperature. See Environment section for details · Process Pressure Range: –1 to +160 bar (–14.5 to +2 321 psi)
The Endress + Hauser Micropilot M FMR67B is a non-contact free-space radar transmitter for continuous level measurement of bulk solids.
Micropilot S FMR532
Level measurement › Radar level
Ambient temperature range (Standard): -40 °C to +80 °C (-40 °F to +176 °F) · Ambient temperature range (Custody transfer): -25 °C to +55 °C (-13 °F to +131 °F) · Process temperature range: -40 °C to +150 °C (-40 °F to 302 °F)
The Micropilot S FMR532 is a non-contact radar level transmitter designed for continuous measurement in custody transfer and inventory control applications.
Micropilot S FMR540
Level measurement › Radar level
Behavior if Measuring Range is Exceeded: Configurable; default is 22 mA current output and a digital warning (E651) · Process Temperature Range: -40 °C to +200 °C (-40 °F to 391 °F) · Accuracy: Better than 1 mm (0.04 in)
The Micropilot S FMR540 is a continuous, non-contact radar level transmitter for custody transfer and inventory control, offering accuracy better than 1 mm.
Micropilot Wireless FWR30
Level measurement › Radar level
Maximum measuring range: 30 m (98 ft) · Level Accuracy: ±2 mm (0.08 in) · Ambient Temperature Accuracy: ±2 °C (4 °F)
The Endress+Hauser Micropilot FWR30 is a battery-operated free-space radar level sensor designed for remote and mobile applications.
Prosonic FMU30
Level measurement › Ultrasonic level
Ambient temperature range: -20 °C to +60 °C (-4 °F to +140 °F) · Process temperature range: -20°C to +60°C (-4 °F to +140 °F) · Process pressure range: 0.7 bar to 3 bar abs. (10.15 psi to 43.5 psi)
The Prosonic FMU30 is a compact, non-contact ultrasonic transmitter for continuous level measurement of fluids, pastes, and bulk materials, offering system integration...
Prosonic FMU40
Level measurement › Ultrasonic level
Pressure Range: 0.7 to 3 bar abs. (10.15 to 43.5 psi abs.) · Ambient Temperature Range: -40 to +80 °C (-40 to +176 °F). LCD display functionality limited below -20 °C and above +60 °C · Output Signal: 4 to 20 mA with HART protocol
The Endress + Hauser Prosonic FMU41 is a compact, two-wire transmitter utilizing ultrasonic technology for non-contact level and flow measurement of liquids and bulk...
Prosonic FMU42
Level measurement › Ultrasonic level
Process temperature range: –40 to +80 °C (–40 to +176 °F) · Process pressure range: 0.7 to 2.5 bar abs. (10.15 to 36.25 psi) · Ambient temperature range: –40 to +80 °C (–40 to +176 °F)
The Prosonic FMU42 is a compact, two-wire transmitter utilizing ultrasonic technology for non-contact level and flow measurement in liquids and bulk solids.
Prosonic FMU44
Level measurement › Ultrasonic level
Process Temperature Range: –40 to +80 °C (–40 to +176 °F) · Process Pressure Range: 0.7 to 2.5 bar abs. (10.15 to 36.25 psi) · Ambient Temperature Range: –40 to +80 °C (–40 to +176 °F)
The Endress + Hauser Prosonic FMU44 is a compact, non-contact ultrasonic transmitter for level and flow measurement.
Prosonic S FDU90
Level measurement › Ultrasonic level
Connection threads: G1", G1-1/2", NPT1", NPT1-1/2" (depending on version) · Suitable power supply unit: RNB130 from Endress+Hauser · Process temperature: –40 to +80 °C (–40 to +176 °F)
The Prosonic S FDU90 is an ultrasonic sensor designed for non-contact level measurement of liquids and bulk solids, and for flow measurement in open channels.
Prosonic S FDU91
Level measurement › Ultrasonic level
Maximum measuring range: 10 m (33 ft) in liquids; 5 m (16 ft) in bulk solids · Process connection: G 1" or NPT 1" (depending on version) · Suitable power supply unit: RNB130 from Endress+Hauser
The Prosonic S FDU91 is an ultrasonic sensor for continuous, non-contact level measurement of liquids and solids, as well as flow measurement in open channels.
Prosonic S FDU91F
Level measurement › Ultrasonic level
Maximum Measuring Range: 10 m (33 ft) for liquids; 5 m (16 ft) for bulk solids · Range Chart: Provided to estimate the sensor range based on total calculated attenuation · IP66 protective housing for RNB130 power supply unit: Order number: 51002468
The Endress+Hauser Prosonic S FDU91F is an ultrasonic sensor for continuous, non-contact level and flow measurement in various applications.
Prosonic S FDU92
Level measurement › Ultrasonic level
Maximum transmitter connection distance: 300 m (984 ft) · Process connection: G 1" or NPT 1" · Process Pressure: 0.7 to 4 bar (10.15 to 58 psi)
The Prosonic S FDU92 is an ultrasonic sensor designed for continuous, non-contact level measurement of liquids and bulk solids, as well as flow measurement in open...
Prosonic S FDU93
Level measurement › Ultrasonic level
Process pressure: 0.7 to 3 bar (10.15 to 43.5 psi) · Supply voltage: Provided by the transmitter (FMU90 or FMU95) · Electromagnetic compatibility: Meets EN 61326 series and NAMUR Recommendation EMC (NE 21). Designed for use in an "industrial environment"
The Prosonic S FDU93 is an ultrasonic sensor designed for continuous, non-contact level measurement of liquids and bulk solids, as well as flow measurement in open...
Prosonic S FDU95
Level measurement › Ultrasonic level
Maximum measuring range: 45 m (148 ft) in bulk solids · IP66 protective housing for RNB130 power supply unit: Order number 51002468 · Maximum total length (sensor cable + extension cable): 300 m (984 ft)
The Prosonic S FDU95 is an ultrasonic sensor for continuous, non-contact level and flow measurement in liquids and bulk solids.
Prosonic S FMU90
Level measurement › Ultrasonic level
Measuring Range: Up to 45 m (148 ft) · Output Signal: Configurable as 4 to 20 mA with HART or 0 to 20 mA without HART. HART signal is on the first analog output only · Voltage Levels: 0: 16 V
The Prosonic S FMU90 is an ultrasonic transmitter for level and flow measurement in liquids or bulk solids, supporting one or two sensors.
Prosonic S FMU95
Level measurement › Ultrasonic level
Measuring range: Up to 45 m (148 ft), depending on the sensor and material · Measured value resolution: 1 mm (0.04 in) with FDU90/FDU91 · Measuring frequency: 0.2 Hz (5 sensors), 0.1 Hz (10 sensors)
The Prosonic S FMU95 is an ultrasonic transmitter for continuous, non-contact level measurement of fluids, pastes, sludge, and bulk materials, supporting up to 10...
Solimotion FTR16
Level measurement › Microwave barrier level
Process temperature range: -20 to +450 °C (-4 to +842 °F) with optional high temperature adapter · Process pressure range: 0.5 to 21 bar (7 to 305 psi) absolute with optional high pressure adapter · Measuring range (Detection range): Maximum range is 5 m (196.9 in) depending on bulk solids (reflection characteristics). The range also depends on the container walls to be penetrated
The Solimotion FTR16 is an ultra-compact flow indicator designed for monitoring bulk solids transport processes, capable of non-contact detection even through...
Solimotion FTR20
Level measurement › Microwave barrier level
Process temperature range: -40 to +450 °C (-40 to +842 °F) with optional high temperature adapter · Measuring range (Detection range): Maximum range is 20 m depending on bulk solids, with an unobstructed radiation path to the surface. The range also depends on the container walls to be penetrated · Operating frequency: 24 GHz ISM
The Solimotion FTR20 is a flow indicator designed for monitoring pneumatic and mechanical transport processes of bulk solids.
Soliwave FDR16
Level measurement › Microwave barrier level
Process temperature range: -20 to +450 °C (-4 to +842 °F) with optional high temperature adapter · Process pressure range: 0.5 to 21 bar (7 to 305 psi) absolute with optional high pressure adapter · Measuring range (Detection range): Up to 20 m (787.4 in) with free path between FQR16 and FDR16. Range is also dependent on container walls
The Endress + Hauser Soliwave FDR16 is an ultra-compact microwave barrier for non-contact point level detection of bulk solids, liquids, and piece goods.
Soliwave FDR56
Level measurement › Microwave barrier level
Process temperature range: -40 to +450 °C (-40 to +842 °F) with optional high temperature adapter · Measuring range (Detection range): Maximum 100 m (3937 in) with free path between FQR56 and FDR56. Range depends on container walls to be penetrated · Operating frequency: 24 GHz ISM
The Soliwave FDR56 is a compact, non-contact microwave barrier for limit detection in bulk solids and liquids.
Soliwave FDR57
Level measurement › Microwave barrier level
Operating Temperature Range: -40 to +70 °C (-40 to +158 °F) · Output Signal: Serial signal for the FTR525 Nivotester. (The FTR525 Nivotester provides 4 to 20 mA, max. two relays or SSR, and open collector outputs) · Integrated Power: No separate supply voltage required; powered via the Nivotester FTR525
The Soliwave FDR57 is a microwave barrier used for non-contact level limit detection up to 100m and bulk flow detection up to 10m.
Source container FQG60
Level measurement › Microwave barrier level
Density Measurement: Suitable for pipe outer diameters ranging from 48 to 273 mm (1.89 to 10.7 in) · Weight: Max. 18 kg (39.69 lbs) · Screening material: Lead (shutter), Lead and 304 (1.4301) (housing/source holder)
The FQG60 is a radiometric level measurement 11 GBq. It features a lightweight, compact design with optimized screening and is fire-resistant up to 821 °C for 30 minutes.
Source container FQG61
Level measurement › Microwave barrier level
Swivel range: 180° · Compressed air connection: G1/8 · Width of emission: FQG61: 10 mm (0.39 in); FQG62: 12 mm (0.47 in)
The It offers safe and easy radioactive.
Source container FQG63
Level measurement › Microwave barrier level
Flange connection: DN 100 PN16 or ANSI 4" 150 lbs · Maximum installation length (L): 30000 mm (1181 in) · Housing dimensions: 232 mm (9.13 in) height, 100 mm (3.94 in) width
The FQG63 is a It features a lightweight spherical design with lead screening and a flexible installation length up to 30 meters, with an optional fire-resistant version...
Source container FQG66
Level measurement › Microwave barrier level
Compressed air connection: G1/8" · Compressed air connection G1/8": Swivel connector: Al, Seal: NBR, Banjo bolt: nickel-plated brass, Internal parts: brass · Screw diameter: M20 or G1/2
The Endress + Hauser It offers manual or pneumatic switch-on/switch-off operation and can accommodate up to 740 GBq of ¹³⁷Cs or 185 GBq of ⁶⁰Co radioactive.
Triple rod probe 11363Z
Level measurement › Microwave barrier level
Probe Rods & Process Connections: Highly corrosion-resistant materials for aggressive products. Specific materials include 316Ti, Alloy B, Alloy C4, PP, PTFE · Metal Process Connections: Refer to drawing (pressure/temperature diagram provided) · Operating pressure (pe): –0.2…+0.2 bar
This Endress+Hauser triple rod probe is designed for two-point control and limit detection in plastic or conducting vessels, with the 11363 Z version suitable for...
Liquicap FTZ61
Level measurement › Capacitance level
Ambient temperature range: 0 to +40 °C (32 to 104 °F) · Output signal: 4 to 20 mA, galvanically isolated · Electrical connection: For PLC, AI modules 4 to 20 mA in accordance with EN 61131–2
The Liquicap FTZ61 is a transmitter designed for capacitive foam detection in single-use bioreactors, mounting externally to non-conducting containers.
Liquicap M FMI51
Level measurement › Capacitance level
Measuring Range: 0.1 to 4.0 m (0.3 to 13 ft) · Temperature Range: -80 to +200 °C (-112 to +392 °F) · Process Connections: Flanges and threads available
The Endress+Hauser Liquicap M FMI51 is a capacitive level sensor for continuous measurement of liquids in a wide temperature range from -80 to +200 °C.
Liquicap M FMI52
Level measurement › Capacitance level
Measuring Range: 0.42 to 10 m (1.38 to 33 ft) · Materials: Process-wetted materials are corrosion-resistant, with FDA-listed options available · Process Pressure: Vacuum to +100 bar (+1450 psi)
The Liquicap M FMI52 is a capacitive level probe for continuous liquid measurement, offering independence from dielectric constant for media with conductivity above 100...
Liquicap M FTI51
Level measurement › Capacitance level
Ambient temperature range: –50 to +70 °C (–40 to +70 °C with F16 housing) · Storage temperature: –50 to +85 °C · Degree of protection: IP66, IP67, IP68, NEMA4X depending on housing type
The Liquicap M FTI51 is a capacitance point level switch designed for detecting liquids, including viscous media, pastes, and foam.
Liquicap T FMI21
Level measurement › Capacitance level
Ambient Temperature Range (Electronic): -40 to 70 °C · Output Signal: 3.8...20.5 mA · Connection Voltage (FEI20): 10 to 30 V DC
The Endress + Hauser Liquicap T FMI21 is a capacitive level sensor for continuous measurement in conductive liquids.
Minicap FTC260
Level measurement › Capacitance level
Max voltage (U~max): 253 V (AC) · Max power (P~max): 1000 VA (cos ϕ = 1), 500 VA (cos ϕ > 0.7) · Current/Voltage ratings: 4 A for U ≤ 30 V; 0.2 A for U ≤ 253 V
The Endress + Hauser Minicap FTC260 is a capacitive point level switch designed for detecting bulk solids and liquids.
Nivector FTI26
Level measurement › Capacitance level
Process temperature range: –20 to +80 °C (–4 to +176 °F) · Process pressure range: –1 to +6 bar (–14.5 to +87 psi) · Ambient temperature range: 0 to 90 °C (32 to 194 °F) (refer to graph for specific limits)
The Endress + Hauser Nivector FTI26 is a capacitance-based point level switch designed for detecting minimum or maximum levels of powdered and fine-grained solids in...
Nivotester FTC325
Level measurement › Capacitance level
Connection cross-section: Max. 1 x 2.5 mm² (14 AWG) or 2 x 1.5 mm² (16 AWG) · Output signal: Potential-free changeover contact for level alarm · Fault-signaling relay: Potential-free changeover contact for fault signaling
The Endress + Hauser Nivotester FTC325 is a point level switch with an intrinsically safe signal circuit suitable for liquid and bulk solid detection in hazardous areas.
Solicap M FTI55
Level measurement › Capacitance level
Input Signal: Probe covered = high capacitance; Probe not covered = low capacitance · Measuring frequency: 500 kHz · Ambient Temperature Effect: < 0.06 % / 10 K related to full scale value (electronic insert); 0.15 pF/10K (capacitance change of connecting cable per meter)
The Solicap M FTI55 is a capacitance point level switch designed for reliable detection in bulk solids.
Solicap S FTI77
Level measurement › Capacitance level
Process Pressure Range: –1 to 10 bar (–14.5 to 145 psi). Permitted pressure values depend on the selected flange · Process Connections: Flanges and threads (R 1½, NPT 1½) · Housing Materials: Aluminum (GD–Al Si 10 Mg), Polyester (PBT–FR), Stainless Steel (316L)
The Solicap S FTI77 is a capacitance point level switch designed for challenging bulk solid applications, including high temperatures and abrasive media.
Levelflex FMP51
Level measurement › Guided radar level
Process temperature range: –196 to +450 °C (–320 to +842 °F) · Process pressure range: –1 to +400 bar (–14.5 to +5 800 psi) · Accuracy: ±2 mm (±0.08 in)
The Levelflex FMP51 is a guided wave radar instrument for liquid level and interface measurement, offering rod, rope, or coax probe options.
Levelflex FMP55
Level measurement › Guided radar level
Accuracy (Level Measurement, Digital Output, ≤ 10 m): ±2 mm (±0.08 in) · Accuracy (Interface Measurement, Digital Output, > 500 mm): ±10 mm (±0.39 in) · Process connection: Flange
The Endress + Hauser Levelflex FMP55 is a guided-wave radar level transmitter for interface measurement in liquids.
Levelflex FMP56
Level measurement › Guided radar level
Accuracy (Analog Output): ±0.02 % of span · Process Connection: Thread (as of ¾") or flange · Process Temperature: –40 to +185 °C (–40 to +365 °F)
The Levelflex FMP56 is a guided-wave radar level measurement device designed for bulk solids.
Levelflex FMP50
Level measurement › Guided radar level
Accuracy: ±2 mm (±0.08 in) · Power supply: External power supply required. Specific terminal voltages and maximum loads depend on the configuration (2-wire, 4-wire) and approvals · Process connection: thread ¾" or adapter flange
The Endress + Hauser Levelflex FMP50 is a guided-wave radar sensor for liquid level measurement.
Double rod probe 11362Z
Level measurement › Conductive level
PP process connections (DN 50, DN 80, DN 100, DN 150): Maximum 1.5 bar abs · PP process connections (2", 3", 4"): Maximum 22 psia · Metal process connections: Operating pressure and temperature depend on the specific connection (refer to drawing in the original document)
The Endress + Hauser 11362Z is a double rod probe designed for limit detection and two-point control in plastic or non-conducting vessels, suitable for corrosive liquids...
Liquipoint T FTW31
Level measurement › Conductive level
Limiting Medium Pressure Range: –1 to 10 bar (–14.5 to 145 psi) · Influence of Ambient Temperature: < 0.05 %/K · Non-hazardous area: –40 to 70 °C (–40 to 158 °F)
The Liquipoint T FTW31 is a conductive point level switch designed for overfill protection, dry running protection, and pump control in conductive liquids with a minimum...
One rod probe 11371
Level measurement › Conductive level
Ambient temperature range: –20°C to +120°C (0°F to 250°F) · Electrical connection: Two terminals for wires with spade terminals (M4 screws) · Without process connection: 0.41 kg
This Endress + Hauser 11371 is a partially insulated rod probe for conductive level limit detection in liquid foodstuffs.
One rod probe 11375Z
Level measurement › Conductive level
Temperature Range: –40 °C to 200 °C · Pressure Range: up to 50 bar · Process connections: Corrosion-resistant steel 316Ti (1.4571)
This is a partially insulated rod probe for conductive level limit detection in process or storage tanks.
One rod probe 11961Z
Level measurement › Conductive level
Measuring Range: Dependent on probe mounting location; maximum probe length is 2000 mm · Process connections: Corrosion-resistant steel 316Ti (1.4571) · Ambient Temperature Range: Depends on fluid temperature and permitted interior temperatures of the connection housing
The Endress + Hauser 11961Z is a partially insulated rod probe for conductive level limit detection in various liquids.
Gamma Modulator FHG65
Level measurement › Radiometric level
Signal transmission: Closed current loop 0 to 5 mA, max. 12 V · Signal lines: 0.5 to 2.5 mm² (20 to 13 AWG) · Synchronization connection terminals (SYNC+, SYNC-): 12 VDC, 5 mA
The Gamma Modulator FHG65 is a radiometric system component designed to enhance measurement accuracy by suppressing background and extraneous radiation.
Gammapilot FMG50
Level measurement › Radiometric level
Output signal: 4 to 20 mA with HART protocol · 4 to 20 mA HART connection: Standard connection for HART communication and power. A HART resistor (typically 250 Ω) is necessary for low-impedance power supplies · Error signal: Indicated on display (symbol, code, description) and via current output (MAX/MIN values)
The Gammapilot FMG50 is a compact transmitter for non-contact level, interface, density, and concentration measurement in vessels.
Gammapilot FTG20
Level measurement › Radiometric level
Output options: Relay, 8/16 mA (passive), or 4 to 20 mA for system integration · Current Output (FEG25): Two-wire DC connection (11 to 36 VDC, 11 to 30 VDC for Ex ia). Suitable for PLCs and AI modules · FEG25 (Current Output): 11 to 36 VDC (11 to 30 VDC for Ex ia). Overvoltage category I. Reverse polarity protection: yes
The Endress + Hauser Gammapilot FTG20 is a non-contact radiometric point level measurement device for liquids, solids, and sludges, suitable for extreme conditions like...
Silopilot M FMM50
Level measurement › Electromechanical level
Maximum Measuring Range: 90 m · Process Connection: Flange, hole dimensions DN100 PN16 according to EN 1092-1 · Input Signal: Remote operation via two inputs (active or passive)
The Silopilot FMM50 is an electromechanical level system for bulk solids and liquids, offering a measuring principle independent of physical properties.
Silopilot T FMM20
Level measurement › Electromechanical level
Clamping range: 7 to 12 mm · Sensing weights: Steel, Stainless steel 316TI, Plastic (PVC), Medium bag (Polyester), Oval float (Stainless steel 316TI). Variants for separation layer detection are available as accessories · Tape running speed: 0.16 to 0.25 m/s
The Endress + Hauser Silopilot FMM20 is an electromechanical level system designed for light bulk solids and liquids in bunkers and silos, offering reliable measurement...
Soliswitch FTE20
Level measurement › Electromechanical level
Ambient temperature range: –20 to 60 °C (–4 to 140 °F) · Medium temperature range: –20 to 80 °C (–4 to 176 °F) · Process pressure range: ≤ 1.5 bar overpressure
The Soliswitch FTE20 is a rotary paddle point level switch designed for robust, reliable detection in bulk solids silos.
Ceraliquid CPS41
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: Not to be used below -15 °C (5 °F) · Process connection: Pg 13.5 · Available in four lengths: 120, 225, 360 and 425 mm
The Ceraliquid CPS41 is a digital or analog pH electrode designed for process engineering with a ceramic diaphragm and KCl liquid electrolyte.
Ceramax CPS341D
Liquid analysis › pH sensors &Transmitters
Temperature Measuring Range: 0 to 140 °C (32 to 284 °F) · Process Pressure Range: 0.8 to 7 bar (11.6 to 101.5 psi) (absolute) · Process Temperature Range: 0 to 140 °C (32 to 284 °F)
The Ceramax CPS341D is a digital pH sensor with Memosens technology designed for pharmaceutical and food production applications.
CPS31D
Liquid analysis › pH sensors &Transmitters
pH: 1 to 12 · Temperature: 0 to 80 °C (32 to 176 °F) · Overall length: 120 mm (4.70 in)
This is a digital pH sensor featuring Memosens technology designed for drinking water and swimming pool applications.
CTS1
Liquid analysis › pH sensors &Transmitters
Measuring range (in conjunction with Liquiline M CM42): –35 to 250 °C (–31 to 482 °F) · Measuring range (in conjunction with Liquisys M CPM223/253): –50 to 150 °C (–58 to 302 °F) · Process connection: Pg 13.5
The CTS1 is a temperature sensor designed for automatic temperature compensation in pH measurements and suitable for immersion or flow assemblies.
FlowFit CPA25
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: -15 to +60 °C (5 to +140 °F) · Process temperature range: 0 to 80 °C (32 to 176 °F) · Process pressure range: 0 to 6 bar (0 to 87 psi) relative
The FlowFit CPA25 is a flow assembly designed for industrial auxiliary processes and water/wastewater treatment, accommodating up to three 12 mm sensors to maintain wet...
Liquiline CM14
Liquid analysis › pH sensors &Transmitters
Output signal: 2 x 0/4 to 20 mA, active, galvanically isolated · Measuring ranges: Dependent on connected sensor · Power supply: Universal power supply 24 to 230 V AC/DC (±20 % / +10 %) 50/60 Hz
The Endress + Hauser Liquiline CM14 is a four-wire transmitter designed for panel or cabinet installation, supporting pH, ORP, conductivity, and oxygen measurements.
Liquiline Compact CM72
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: –20 to 85 °C (–4 to 185 °F). The maximum ambient temperature depends on process temperature and installation · pH: 0 to 14 pH · Resolution: < 5 µA
The Liquiline Compact CM72 is a space-saving, two-wire transmitter designed for monitoring and controlling industrial and environmental processes with digital Memosens...
Liquiline Compact CM82
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: –20 to 85 °C (–4 to 185 °F) · Output Signal: 4 to 20 mA / HART, galvanically isolated from sensor circuits · Measuring Range: Refer to the documentation of the connected sensor
The Liquiline Compact CM82 is a configurable two-wire transmitter for Memosens sensors, supporting pH, ORP, conductivity, and oxygen measurements.
Liquiline CY42
Liquid analysis › pH sensors &Transmitters
Selection cues: measuring range · accuracy · output signal and process connection
The Liquiline CY42 is a DAT module for Endress+Hauser CM42 devices, offering configuration saving, firmware updates, and language changes.
Liquiline M CM42
Liquid analysis › pH sensors &Transmitters
Max. load with supply voltage 24 V: 500 Ω · Max. load with supply voltage 30 V: 750 Ω · Current output / HART: Minimum supply voltage of 11.5 V (without HART) or 12.5 V (with HART). Max. 30 V DC. Nominal voltage: 24 V DC
The Endress + Hauser Liquiline M CM42 is a two-wire transmitter designed for liquid analysis in process, pharmaceutical, and food technology applications, including...
Liquiline Mobile CML18
Liquid analysis › pH sensors &Transmitters
Output signal: Memosens M12 (maximum 80 mA) · Input power (M12 connection): 5 V; 0.6 A · M12 connection: CuZn, nickel-plated
The Liquiline Mobile CML18 is a portable, multiparameter device designed for connecting digital sensors with Memosens technology.
Memobase Plus CYZ71D
Liquid analysis › pH sensors &Transmitters
Power Supply: 5 V DC via USB. USB hub requires a power unit · Output: Mini USB 2.0 Type B, USB class HID · Output Voltage: 2.8 to 3.3 V
Memobase Plus CYZ71D is multichannel multiparameter software for managing the lifecycle of digital Memosens sensors used in liquid analysis.
Memocheck CYP02D-CYP03D
Liquid analysis › pH sensors &Transmitters
Dimensions: Ø 20 mm (0.79 in) diameter, 40.0 mm (1.57 in) length
The Memocheck CYP02D and CYP03D are testing tools for analysis measuring points that utilize Memosens Technology for use in chemical, food, and wastewater applications.
Memocheck CYP02E
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: –15 to 70 °C (5 to 158 °F) · Storage temperature range: –15 to 70 °C (5 to 158 °F) · pH ISFET: 7
The Memocheck CYP02E is a maintenance-free service tool designed for on-site checking and configuration of Memosens transmitters.
Memosens 31E
Liquid analysis › pH sensors &Transmitters
Process temperature range: –15 to 80 °C (5 to 176 °F) · Process pressure range: 0.8 to 4 bar (11.6 to 58 psi) absolute · pH measuring range: 1 to 12
The Memosens CPS31E is a digital pH sensor designed for standard applications in drinking water and swimming pool water, offering Memosens 2.0 technology.
Memosens 61E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: Not specified, but avoid use below 0 °C (32 °F) due to risk of frost damage · Process Pressure Range: 0.8 to 7 bar (11.6 to 101.5 psi) absolute for Application M and N · Process Connections: Pg 13.5
The Memosens 61E is a sterilizable pH sensor for hygienic and sterile bioreactor applications in life sciences and the food industry.
Memosens CPF81E
Liquid analysis › pH sensors &Transmitters
Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) (absolute) · Ambient Temperature Range: 0 to 50 °C (32 to 122 °F) · Process connections: NPT ¾"
The Memosens CPF81E is a digital pH sensor designed for industrial water and wastewater treatment, as well as flotation and leaching applications.
Memosens CPL51E
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: Do not use the sensor at temperatures below 0 °C (32 °F) (Risk of damage from frost) · Process temperature range: 0 to 80 °C (32 to 176 °F) · Process connections: Pg 13.5
The Memosens CPL51E is a digital pH sensor with Memosens 2.0 technology designed for laboratory measurements and field sampling.
Memosens CPL53E
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: Do not use below –15 °C (5 °F) · Process temperature range: 0 to 80 °C (32 to 176 °F) · Process connections: Pg 13.5
The Memosens CPL53E is a digital pH sensor with Memosens 2.0 technology, ideal for standard laboratory measurements and random sampling.
Memosens CPL59E
Liquid analysis › pH sensors &Transmitters
Process temperature range: 0 to 100 °C (32 to 212 °F) · Application temperature range: 0 to 100 °C (32 to 212 °F) · Ambient temperature range: Do not use below 0 °C (32 °F)
The Memosens CPL59E is a digital pH sensor utilizing Memosens 2.0 technology, featuring a PTFE junction and ion trap for demanding applications.
Memosens CPS11E
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: Do not use below –15 °C (5 °F) · Process connection: Pg 13.5 · Maximum pressure: Up to 17 bar (246.5 psi) absolute for applications A and B. Up to 7 bar (101.5 psi) absolute for application F
The Memosens CPS11E is a digital pH sensor featuring Memosens 2.0 technology for use in standard process and environmental applications.
Memosens CPS16E
Liquid analysis › pH sensors &Transmitters
Installed lengths available: 120 mm, 225 mm, 360 mm, 425 mm · Sensor shaft diameter: Ø 11.9 mm (0.47 in) · 120 mm installed length: 40 g (1.4 oz)
The Memosens CPS16E is a pH/ORP sensor for standard applications in process technology and environmental engineering, capable of simultaneous pH, ORP, and rH measurements.
Memosens CPS41E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: Not specified, but frost risk below –15 °C (5 °F) · Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) absolute · Process Connections: Pg 13.5
The Endress + Hauser Memosens CPS41E is a digital pH sensor for low conductivity media and hazardous areas, featuring Memosens 2.0 technology for safe, digital data...
Memosens CPS47E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: -15 °C (5 °F) to 50 °C (122 °F) (Note: Do not use below -15 °C due to frost risk) · Process Temperature Range: –15 to 135 °C (5 to 275 °F) · Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) absolute
This ISFET sensor is designed for accurate pH measurement in challenging media including clogging substances and organic solvents, featuring Memosens 2.0 digital...
Memosens CPS71E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: Not to be used below –15 °C (5 °F) · Process Temperature Range: 0 to 140 °C (32 to 284 °F). For TP/TU versions, 140 °C (284 °F) is for sterilization only. Continuous operation maximum 100 °C (212 °F) due to pressure loss · Process Connections: Pg 13.5
The Memosens CPS71E is a digital pH sensor designed for chemical process applications, featuring Memosens 2.0 technology and a poison-resistant reference system with an...
Memosens CPS76E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: 0 to 50 °C (32 to 122 °F). Avoid temperatures below freezing · Process Connections: Pg 13.5 · Temperature: 0 to 140 °C (32 to 284 °F)
The Endress+Hauser Memosens CPS76E is a pH/ORP sensor designed for process technology, suitable for challenging applications with rapidly changing pH values or high...
Memosens CPS77E
Liquid analysis › pH sensors &Transmitters
Ambient Temperature Range: –15 to 50 °C (5 to 122 °F). Avoid temperatures below –15 °C to prevent frost damage · Process Temperature Range: –15 to 135 °C (5 to 275 °F). Operation at high temperatures, especially with strong alkalis, can reduce sensor operating life · Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) absolute
This is an ISFET sensor for pH measurement in hygienic, sterile, and hazardous applications, featuring Memosens 2.0 technology for digital data transmission and sensor...
Memosens CPS91E
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: -15 °C (5 °F) to maximum process temperature. (Note: Do not use below -15 °C due to frost risk) · Process temperature range: 0 to 110 °C (32 to 230 °F) · Process pressure range: 0.8 to 14 bar (11.6 to 203 psi) absolute. Caution is advised regarding rapid heating of pressurized sensors
This is a digital pH sensor with Memosens 2.0 technology designed for heavily polluted media, featuring an open aperture and ATEX, IECEx, CSA C/US, NEPSI, Japan, and...
Memosens CPS96E
Liquid analysis › pH sensors &Transmitters
Process Temperature Range: 0 to 110 °C (32 to 230 °F) · Process Pressure Range: 0.8 to 14 bar (11.6 to 203 psi) absolute · Process Connections: Pg 13.5
This Memosens CPS96E is a pH/ORP sensor designed for heavily polluted media with suspended solids, utilizing Memosens 2.0 technology and suitable for hazardous areas.
Memosens CPS97E
Liquid analysis › pH sensors &Transmitters
Process Temperature Range: –15 to 110 °C (5 to 230 °F) · Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) absolute · Ambient Temperature Range: Not below –15 °C (5 °F)
The Memosens CPS97E is an ISFET sensor for pH measurement in contaminated media, including water treatment and wastewater applications.
Orbipore CPS91
Liquid analysis › pH sensors &Transmitters
Ambient temperature range: -15 to 50 °C (5 to 122 °F). Note: Sensor must not be used if temperature drops below -15 °C (5 °F) · pH range: 0 to 14 pH · Process connection: Pg 13.5
The Orbipore CPS91 is a pH electrode designed for chemical processes, pulp and paper, and flue gas cleaning, handling contaminated media and hazardous areas.
Orbitex W CPS21
Liquid analysis › pH sensors &Transmitters
Operating temperature range: –15 to 60 °C (5 to 140 °F) · Process temperature range: –15 to 60 °C (5 to 140 °F) · Process pressure range: 0 to 6 bar (0 to 87 psi)
This is an Orbitex W CPS21 pH sensor with an open ring junction for wastewater applications.
PuriSys CPF201
Liquid analysis › pH sensors &Transmitters
pH measurement range: 0 ... 14 pH · Temperature measurement range: 2 ... 75 °C / 36 ... 167 °F · Cable connection: TOP 68 quick disconnect, water tight connector
The PuriSys CPF201 is a compact pH electrode designed for boiler feed water, power plant applications, and pharmaceutical WFI.
Topclean S CPC30
Liquid analysis › pH sensors &Transmitters
Power Supply (Non-hazardous area): 100 to 230 V AC or 24 V AC/DC · Accuracy Features: Medium temperature compensation and Isothermic intersection compensation · Hazardous area (Ex): -10 to +50 °C (+14 to +122 °F)
The Topclean S CPC30 is an automatic measuring and cleaning system for pH/ORP applications in various industrial sectors, including process, wastewater, food, and...
Liquiline To Go CYM292-Ex-CYM291
Liquid analysis › pH sensors &Transmitters
Compatibility: Designed for optical sensors such as OUSAF44, OUSAF12, OUSAF22, OUSAF46, and OUSTF10 · Process Temperature: 0 to 135 °C (32 to 275 °F). Users must also comply with the maximum permitted process temperature of the sensor · Process Pressure: Maximum 11 bar (15 psi), absolute, at 25 °C (77 °F)
The CUA261 adapter is designed for installing Endress + Hauser optical sensors in VARIVENT process connections.
CleanFit CPA450
Liquid analysis › Assemblies
Ambient temperature range: 0 to 80 °C (32 to 176 °F) · Storage temperature: 0 to 80 °C (32 to 176 °F) · Process temperature: -15 to 130 °C (5 to 266 °F)
The CleanFit CPA450 is a retractable assembly designed for pH, redox, oxygen, and conductivity measurements in power stations and the chemical industry.
CleanFit CPA472D
Liquid analysis › Assemblies
Rinse Connections: 2 x G¼ (internal) or 2 x NPT ¼" (internal) or 2 x pipe 8 x 60 Swagelok as nozzle · Process temperature: 0 to 140 °C (32 to 284 °F) · Ambient temperature: Not below 0 °C (32 °F)
The CleanFit CPA472D is a heavy-duty retractable process assembly for pH and ORP sensors in harsh industrial environments.
CleanFit CPA474
Liquid analysis › Assemblies
Air pressure: 4 to 6 bar (60 to 90 psi) · Minimum nominal diameter of air lines: 4 mm (0.16 inches) · Ambient Temperature: Not below 0 °C (32 °F). With an optional inlet/outlet safety seal, the ambient temperature must not exceed 80 °C (176 °F)
The CleanFit CPA474 is a retractable plastic process assembly designed for pH and ORP electrodes, offering safe process isolation via a ball valve.
CleanFit CPA871
Liquid analysis › Assemblies
Immersion tube, process connection, service chamber: Stainless steel 1.4404 (AISI 316L) Ra < 0.76 / PEEK / Alloy C22 Ra < 0.76 / PVDF / PVDF conductive / PP · Rinse connections: Stainless steel 1.4404 (AISI 316L) or Alloy C22 · Process Connections: Various types are available including Clamp, Flange (EN1092-1, ASME B16.5, JIS B2220), Dairy fitting, and Thread (NPT, ISO 228)
The CleanFit CPA871 is a flexible retractable process assembly for standard 12 mm pH and redox sensors, suitable for demanding applications including hazardous areas.
CleanFit CPA875
Liquid analysis › Assemblies
Ambient Temperature Range: -10 to +70 °C (+10 to +160 °F) · Process Temperature Range: –10 to 140 °C (14 to 284 °F) · Process Connections: Various common process connections are available, including Clamp, Aseptic DIN 11864, BioControl, BioConnect, Dairy fitting, ISO228 Thread, and Varivent
The Endress+Hauser Cleanfit CPA875 is a modular retractable process assembly for in-line measurement of parameters like pH, ORP, and oxygen in sterile, hygienic, and...
CleanFit CUA451
Liquid analysis › Assemblies
Maximum process pressure: 10 bar (145 psi) · Manual insertion/retraction pressure: Maximum 2 bar (29 psi) · Ambient temperature: 0 to 50 °C (32 to 122 °F)
This assembly is designed for use in: Drinking water and process water:Filter monitoring and backflushing, phase separation monitoring, raw water monitoring, and sludge...
CleanFit P CPA473
Liquid analysis › Assemblies
Connection Thread: 2 x G 1/8 · Rinse connection socket: Stainless steel 1.4404 (AISI 316L) · Process Connection: Threaded, dairy fitting, or flange options
The CleanFit P CPA473 is a retractable stainless steel process assembly designed for pH and ORP electrodes across various industries.
CPK-1-2-3-6-7-9-12-VBA-VBE
Liquid analysis › Assemblies
Continuous temperature range (standard / high temperature): –25 ... +80 °C / 0 ... 130 °C · Cable sheath (standard / high temperature): PVC / TPE
These are Endress+Hauser CPK pH and redox measuring cables and junction boxes designed for high-impedance electrode systems.
CYA680
Liquid analysis › Assemblies
Flow assembly: Stainless steel 1.4404/1.4435 or PVDF · pH sensors: Memosens CPS61E, Ceragel CPS71, Memosens CPS71E · pH-ISFET sensors: Memosens CPS47E, Memosens CPS77E
This CYA680 flow assembly is designed for hygienic and sterile applications in the life sciences and chemical industries, accommodating 12 mm sensors in small pipe...
CYH101
Liquid analysis › Assemblies
Turbidity sensors: TurbiMax W CUS 31, TurbiMax W CUS 41
The Endress+Hauser CYH 101 is a universal suspension assembly holder designed for open channels, basins, and tanks in wastewater treatment applications.
DipFit CLA140
Liquid analysis › Assemblies
Ambient temperature range: -10 to +70 °C (+10 to +160 °F) · Storage temperature: -10 to +70 °C (+10 to +160 °F) · Degree of protection: IP65
This is an immersion assembly with a flange connection designed for demanding chemical, power generation, and metal processing applications.
DipFit CPA111
Liquid analysis › Assemblies
Process temperature: -10 to +80 °C (+10 to +180 °F) · Ambient temperature: -10 to +80 °C (+10 to +180 °F) · Other lengths available: 500 to 3000 mm (19.7 to 118 inch)
The DipFit CPA111 is an immersion and installation assembly for pH/ORP and temperature sensors in open and closed vessels.
DipFit CPA140
Liquid analysis › Assemblies
Ambient temperature range: -10 to +70 °C (+10 to +160 °F) · Storage temperature: -10 to +70 °C (+10 to +160 °F) · Degree of protection: IP65
The Dipfit CPA140 is an immersion assembly with flange connection for demanding industrial applications, capable of housing three 12 mm sensors.
EcoFit CPA640
Liquid analysis › Assemblies
Maximum pressure: 10 bar · Sensor insertion length: 120 mm (4.72 in) · Approximate weight: 0.1 to 0.3 kg (0.22 to 0.66 lbs) depending on version
The EcoFit CPA640 is a universal compact assembly for installing 120 mm sensors with Pg 13.5 threads into NPT process connections, suitable for water and process...
Flexdip CYA112
Liquid analysis › Assemblies
Ambient temperature range: -20 to 60 °C (-4 to 140 °F) · Process temperature range: 0 to 60 °C (32 to 140 °F) · Immersion tube connection: M36 male thread
The Flexdip CYA112 is an immersion assembly designed for water and wastewater applications in plant construction.
Flexdip CYH112
Liquid analysis › Assemblies
Ambient temperature range: -20 to 60 °C (-4 to 140 °F) · Diameter: 40 mm (1.6 in) · Length: 5 m (16.4 ft)
The Endress + Hauser Flexdip CYH112 is a versatile holder for water and wastewater assemblies, designed for simple and cost-effective installation on floors, walls,...
FlowFit CPA240
Liquid analysis › Assemblies
Flow vessel: PVDF / stainless steel 1.4404 (AISI 316L) · Shock-protection stud: PVDF / stainless steel 1.4401 (AISI 316) · Sensor length: 120 mm
The FlowFit CPA240 is a versatile flow assembly designed for 12 mm sensors in demanding industrial applications, including chemical processing and power generation.
FlowFit CYA21
Liquid analysis › Assemblies
Sensor connection: NPT 1/2" or Pg 13.5 · Pipe connection: 6 x 1 mm (open pipe outlet) · Process temperature: -15 to 100 °C (5 to 212 °F), non-freezing
The FlowFit CYA21 is a universal assembly for analytical systems in industrial utilities, suitable for power stations and water treatment applications.
FlowFit CYA27
Liquid analysis › Assemblies
pH Range: pH 1 to 12 · Recommended flow range (5 l version): 5 to 8 l/h (1.32 to 2.11 gal/h) · Recommended flow range (30 l version): 30 to 40 l/h (7.92 to 10.46 gal/h)
The FlowFit CYA27 is a modular bypass flow assembly for multiparameter water analysis, capable of measuring up to six parameters and offering flexible installation.
FlowFit W CUA250
Liquid analysis › Assemblies
Nominal Operating Range: 10 ... +55 °C · Limit Operating Range: 10 ... +60 °C · Storage Temperature Range: 20 ... +65 °C
The FlowFit W CUA250 is a process and flow assembly designed for turbidity measurement applications in wastewater and industrial water recycling.
Memosens CYK10-CYK11
Liquid analysis › Assemblies
Dimensions: Memosens data cable used with sensors utilizing contactless inductive signal transmission. Available in versions for use in hazardous areas · CYK10 and CYK11 Cable Sheath Material: TPE · Material: Aluminum, painted
The Endress + Hauser Memosens CYK10 and CYK11 are measuring cables and installation accessories for Memosens sensors, offering contactless digital signal transmission and...
Unifit CPA842
Liquid analysis › Assemblies
Assembly (various process connections): 0.3 to 1.4 kg (0.7 to 3.1 lbs) · Made from high-grade materials: Stainless steel 1.4435 as per BN2 (AISI 316 L) · Protection cover: approx. 0.2 kg (0.4 lbs)
The Unifit CPA842 is a hygienic process assembly designed for the safe installation of 12 mm sensors in food, beverage, and life sciences industries.
DipFit W CPA510
Liquid analysis › Assemblies
Connection: Direct cable connection via Pg screw connection · Electrode Compatibility: For combined pH or redox electrodes filled with gel electrolyte and a length of 120 mm · Pressure Rating: Usable with pressures up to 6 bar
The Endress + Hauser DipFit W CPA510 is a sensor assembly suitable for water and wastewater treatment applications, capable of holding combined pH, redox, or conductivity...
DipFit W CPA530
Liquid analysis › Assemblies
Ingress protection: IP 68 · Hose length: Up to 10 m · Required installation diameter: DN 50
The Endress + Hauser DipFit W CPA 530 is a suspended assembly with a bayonet lock for water and wastewater treatment in conduits, ducts, or tall tanks where clearance is...
Weld-in-adapter
Liquid analysis › Assemblies
Pressure Ratings: Available in PN16, PN25, PN40, PN63, PN100 for DIN EN; Class 150, 300, 600, 900, 1500 for ASME; 10 K, 20 K, 63 K for JIS · Pressure Equipment Directive 2014/68/EU: The adapters covered in this document do not fall under the scope of the Pressure Equipment Directive as they lack a pressure-bearing volume
These weld-in adapters are designed to connect level, pressure, or temperature measuring instruments to vessels or pipes.
Condumax CLS12
Liquid analysis › Conductivty sensors & transmitters
Connection: Via fixed cable or measuring cable CYK71 with shield. Wiring diagram is provided in the transmitter's operating instructions · Threaded connection size: G1 / NPT 1" · Process connection: Stainless steel 1.4571 (AISI 316Ti)
The Condumax CLS12 is a two-electrode conductivity sensor designed for high-temperature and high-pressure applications in power and energy industries, suitable for...
Condumax CLS13
Liquid analysis › Conductivty sensors & transmitters
Temperature Measuring Range: -20 to 250 °C (-4 to 480 °F) · Process Temperature Range: -20 to 250 °C (-4 to 480 °F) · Ambient Temperature Range: -20 to 60 °C (-4 to 140 °F)
The Endress + Hauser Condumax CLS13 is a conductivity sensor designed for high-temperature and high-pressure applications in power plants.
Condumax CLS15
Liquid analysis › Conductivty sensors & transmitters
Process connections: Thread NPT ½" and ¾", Clamp 1½" (as per ISO 2852)
The Condumax CLS15 is a conductivity sensor designed for pure and ultrapure water applications like ion exchange and reverse osmosis.
Condumax CLS16B
Liquid analysis › Conductivty sensors & transmitters
Process connections: Clamp (1", 1½", 2"), Tuchenhagen VARIVENT N (DN 50 to 125), NEUMO BioControl D50 · Ambient temperature: -20 to 60 °C (-4 to 140 °F) · Storage temperature: -25 to +80 °C (-10 to +180 °F)
The Condumax CLS16B is an analog conductivity sensor designed for applications such as ion exchanger monitoring and reverse osmosis.
Condumax CLS19
Liquid analysis › Conductivty sensors & transmitters
Process connections: Thread NPT ½" · Total length: 126 mm (4.96 in) · Threaded shaft length: 73 mm (2.87 in)
The Condumax CLS19 is a conductivity sensor designed for measuring conductivity in pure and ultrapure water applications.
Condumax CLS21
Liquid analysis › Conductivty sensors & transmitters
Conductivity measuring ranges (in relation to water at 25 °C): 10 μS/cm to 20 mS/cm · Clamp process connection: Stainless steel 1.4435 (process connection), EPDM (seal) · Response time (Conductivity): t ≤ 3 s
This is an analog or digital conductivity sensor with Memosens technology, suitable for media with average to high conductivity in applications like wastewater treatment...
DipFit CLA111
Liquid analysis › Conductivty sensors & transmitters
Process temperature: -10 to +80 °C (+10 to +180 °F) · Ambient temperature: -10 to +80 °C (+10 to +180 °F) · Weight: Approx. 4.0 kg (8.8 lbs)
The DipFit CLA111 is an immersion and installation assembly for conductivity sensors in open and closed vessels.
Liquiline To Go CYM292-Ex-CYM291
Liquid analysis › Conductivty sensors & transmitters
Temperature sensor NTC30: -20 to +120 °C (-4 to 248 °F) · Temperature sensor Pt1000: -40 to +250 °C (-40 to 482 °F) · Storage temperature: -25 to +70 °C (-13 to +158 °F)
The Liquiline To Go CYM292-Ex-CYM291 is a portable multiparameter handheld device for pH, ORP, conductivity, and oxygen measurements.
Liquisys M CLM223-253
Liquid analysis › Conductivty sensors & transmitters
Ambient temperature range: -10 to +55 °C (14 to 131 °F) · Range: -35 to +250 °C (-31 to 482 °F) · Output signal: 0/4 to 20 mA, galvanically isolated, active
The Liquisys M CLM223/253 is a transmitter for conductive and inductive sensors used in various water treatment applications including ultrapure water.
Memosens CLL47E
Liquid analysis › Conductivty sensors & transmitters
Process connection: Stainless steel 1.4435 (AISI 316L) · Temperature compensation: Pt1000 (Class A according to IEC 60751) · Ambient temperature: –20 to 60 °C (–4 to 140 °F)
This Endress + Hauser Memosens CLL47E is a digital contacting conductivity sensor for laboratory and field measurements, designed for sticky and viscous samples.
Memosens CLS15E
Liquid analysis › Conductivty sensors & transmitters
Hazardous area approvals: Various certifications including ATEX (Ex ia IIC T3/T4/T6 Ga), CSA C/US, and EAC Ex are available for specific model variants · Test reports: Manufacturer inspection certificate stating the individual cell constant · Flow assembly: Stainless steel assembly for sensors with NPT ½" thread
This digital conductivity sensor with Memosens 2.0 technology is designed for measurements in pure and ultrapure water applications like ion exchangers and reverse...
Memosens CLS16E
Liquid analysis › Conductivty sensors & transmitters
Material: Stainless steel 1.4435 (AISI 316L) · Temperature compensation: Pt1000 (Class A according to IEC 60751) · Conductivity (t): ≤ 2 s
The Memosens CLS16E is a digital conductivity sensor designed for precise measurements in pure and ultrapure water applications.
Memosens CLS21E
Liquid analysis › Conductivty sensors & transmitters
Process connection: G1 thread or NPT 1" thread · Temperature compensation: Pt1000 (Class A according to IEC 60751) · Ambient temperature: -20 to 60 °C (-4 to 140 °F)
The Endress + Hauser Memosens CLS21E is a digital conductivity sensor designed for measurements in media with medium or high conductivity, suitable for applications in...
Memosens CLS82E
Liquid analysis › Conductivty sensors & transmitters
Temperature (with other process connection, with temperature prediction): t ≤ 28 s · Temperature (with other process connection, -5 to 140 °C): ≤ 1.0 K · Process connection Pg 13.5: 0.06 to 0.09 kg (0.13 to 0.20 lbs)
The Memosens CLS82E is a hygienic conductivity sensor designed for a wide range of applications including fermentations, CIP monitoring, and ballast water cleaning.
Smartec CLD134
Liquid analysis › Conductivty sensors & transmitters
Temperature compensation range: -10 to +150 °C (14 to 302 °F) · Process Connections: Available with commonly used hygienic connections, with custom options on request · Electrical Connection: Terminals for signal outputs, auxiliary voltage, binary inputs, and power supply
The Smartec CLD134 is a hygienic inductive conductivity and concentration measuring system for applications in the food, beverage, pharmaceutical, and biotechnology...
Smartec S CLD132
Liquid analysis › Conductivty sensors & transmitters
Output Signal: 0/4–20 mA, galvanically isolated (Conductivity). Optional second current output for Temperature · Conductivity (Signal Output): Max. 0.75 % of current output range · Temperature (Signal Output): Max. 0.75 % of current output range
The Smartec S CLD132 is a measuring system with an inductive sensor for conductivity and concentration measurement, widely used in the food and beverage industries for...
CleanFit COA451
Liquid analysis › Oxygen sensors & transmitters
Medium Temperature: 0 to 85 °C (32 to 185 °F) · Medium Pressure: Max. 10 bar (145 psi) · Manual Insertion/Retraction Pressure: Not to exceed 2 bar (29 psi)
The Endress+Hauser CleanFit COA451 is a manually operated retractable assembly designed for oxygen sensors in water, wastewater, and industrial applications.
COS51E
Liquid analysis › Oxygen sensors & transmitters
Measuring range drift: < 0.1 % per week · Process connection: Pg 13.5 (Torque max. 3 Nm) · Dimensions: See diagram (Page 11)
The Endress + Hauser Memosens COS51E is an amperometric oxygen sensor for water, wastewater, and industrial utilities, featuring Memosens 2.0 technology for reliable data...
FlowFit COA250
Liquid analysis › Oxygen sensors & transmitters
Ambient temperature range: 0 ... 50 °C (32 ... 120 °F) · Process temperature range: 0 to 50 °C (32 to 120 °F), non-freezing · Process connection: G¾ (for usual fittings)
The FlowFit COA250 is a PVC flow assembly for 40 mm diameter oxygen sensors, suitable for wastewater and surface water applications.
Liquiline CM442-CM444-CM448
Liquid analysis › Oxygen sensors & transmitters
Input Signal: Max. 8 binary sensor signals (or 6 with 2DS Ex-i module), optional 2 x 0/4 to 20 mA, 0 to 30 V · Output Signal: 2, 4, 6, or 8 x 0/4 to 20 mA (active, galvanically isolated) · Measuring Range Switching: Can be used for CIP processes and phase separation monitoring
The Liquiline CM442, CM444, and CM448 are multiparameter transmitters designed for industrial and environmental process monitoring using up to eight digital Memosens...
Liquisys M COM223-253
Liquid analysis › Oxygen sensors & transmitters
Ambient temperature range: -10 to +55 °C (+10 to +130 °F) · Signal resolution: Max. 700 digits/mA · Signal output (Oxygen): Max. 0.75 % of measuring range
The Endress + Hauser Liquisys M COM223/253 is a transmitter for oxygen sensors used in various water treatment applications.
Liquisys M COM223F-253F
Liquid analysis › Oxygen sensors & transmitters
Signal current: 0 to 650 nA · Voltage: 10 to 50 V · Power consumption: max. 10 mA
The Endress + Hauser Liquisys M COM223F-253F is a transmitter for dissolved oxygen sensors used in process control for enzyme and biotechnological production.
Memosens COL37E
Liquid analysis › Oxygen sensors & transmitters
Ambient temperature range: –5 to +60 ˚C (23 to 140 ˚F) · Storage temperature range: -25 to 50 °C (-13 to 122 °F) at 95% relative humidity, non-condensing · Process temperature range: –5 to +60 ˚C (23 to 140 ˚F)
This is an optical oxygen sensor for laboratory measurements and field sampling, featuring Memosens 2.0 digital technology.
Memosens COS22E
Liquid analysis › Oxygen sensors & transmitters
Process Pressure Range: Ambient pressure ... 12 bar (absolute) · Storage Temperature Range: -25 to 50 °C. Store with watering cap filled with tap water · Connection: Memosens technology with inductive, non-contact data transmission. Uses measuring cable CYK10
The Memosens COS22E is a hygienic amperometric oxygen sensor featuring Memosens 2.0 technology for applications in pharmaceuticals, biotechnology, and hazardous areas.
Memosens COS81E
Liquid analysis › Oxygen sensors & transmitters
Ambient Temperature Range: –5 to +100 °C (23 to 212 °F) · Storage Temperature Range: -25 to 50 °C (-13 to 122 °F) at 95% relative air humidity, non-condensing · Process Pressure Range: 0.02 to 13 bar (0 to 190 psi) abs
This is a hygienic optical oxygen sensor utilizing Memosens 2.0 technology for applications in pharmaceutical fermenters, food quality control, and monitoring explosive...
Oxymax COS22
Liquid analysis › Oxygen sensors & transmitters
Process connection: Pg 13.5 · Measured variable as partial pressure or Vol%: -5 to 90 °C (23 to 194 °F) · Measured variable as concentration: 0 to 80 °C (32 to 176 °F)
The Oxymax COS22 is a digital or analog sensor for residual oxygen measurement in pharmaceutical, chemical, and water treatment applications.
Oxymax COS61
Liquid analysis › Oxygen sensors & transmitters
COS61D Connection: Fixed cable with terminated cores, or optional M12 plug. Connects directly to transmitter terminals or via M12 sensor socket · COS61 Connection: Fixed cable or TOP68 plug connection. Connects via SXP connector to field device or terminal connections for cabinet devices (e.g., Liquisys COM223) · Housing connection: POM
The Oxymax COS61 is a digital optical sensor for measuring dissolved oxygen in wastewater, water monitoring, and water treatment applications.
Oxymax W COS41
Liquid analysis › Oxygen sensors & transmitters
Ambient temperature range: –5 to 50 °C (20 to 120 °F) · Signal current in air: approx. 300 nA · With TOP68 plug-in connection: 0.3 kg / 0.66 lbs
The Oxymax W COS41 is a potentiostatic amperometric two-electrode sensor for the continuous measurement of dissolved oxygen in various water management applications.
CYA251
Liquid analysis › Oxygen sensors & transmitters
Dimensions of process connections (X, Y): Vary by connection type. For example, NPT ¾" female thread has X=83 mm (3.27 in) and Y=50.5 mm (1.99 in). Adhesive tap DN50/d63 has X=0 mm (0 in) and Y=63 mm (2.48 in) · Flow vessel, process connections, adapter, union nut: PVC · Ambient temperature: 0 to 60 °C (32 to 140 °F)
The CYA251 is a universal flow assembly designed for nitrate/SAC, turbidity, and oxygen sensors in wastewater, drinking water, and industrial utility applications.
Liquiline System CA80AL
Liquid analysis › Analyzers for hardness, iron & more
Measuring Range: 15 to 1000 µg/l (ppb) Al. An optional dilution function allows for configurable measuring ranges up to 20,000 µg/l (ppb) with dilution factors of 5, 10, or 20 · Input Signal: 2 x 0/4 to 20 mA (optional), passive, potentially isolated · Process Connection: Plug-in connector for rigid hoses (OD 4 mm) or hose barb for flexible hoses (ID 1.6 mm) for sample inlet. Hose barb for flexible hoses (ID 13 mm) for outlet
The Liquiline System CA80AL is a wet-chemical analyzer for near-continuous determination of aluminum in liquid media using the Pyrocatechol violet method.
Liquiline System CA80AM
Liquid analysis › Analyzers for hardness, iron & more
Input Signal: 2 x 0/4 to 20 mA (optional), passive, potentially isolated · Current Outputs: Span 0 to 23 mA, Linear signal characteristic, Output voltage max. 24 V · Relay Outputs: 1 alarm relay (changeover contact) standard, 2 or 4 optional. Maximum load: 0.5 A (alarm relay), 2.0 A (other relays)
The Liquiline System CA80AM is a wet-chemical analyzer for continuous ammonium determination in liquids using a colorimetric method.
Liquiline System CA80COD
Liquid analysis › Analyzers for hardness, iron & more
Automatic measuring range switching: 10 to 5000 mg/l O₂ · Signal characteristic: Linear · Max. cable length: 100 m (330 ft)
The Liquiline System CA80COD is a wet-chemical analyzer designed for determining chemical oxygen demand (COD) in wastewater treatment and industrial applications.
Liquiline System CA80CR
Liquid analysis › Analyzers for hardness, iron & more
Signal Characteristic: Linear · Digital fieldbuses supported: PROFINET, PROFIBUS DP, Modbus TCP, Modbus RS485, and Ethernet IP · Turbidity: 50 NTU
The Liquiline System CA80CR is a wet-chemical analyzer for near-continuous chromate (Cr (VI)) determination in liquid media.
Liquiline System CA80FE
Liquid analysis › Analyzers for hardness, iron & more
Input signal (optional analog current inputs): 2 x 0/4 to 20 mA, passive, potentially isolated · Supply voltage: 100 to 120 V AC / 200 to 240 V AC or 24 V DC (24 V DC not available for "Outdoor" version). Frequency 50 or 60 Hz · Storage temperature: –20 to 60 °C
The Liquiline System CA80FE is a wet-chemical analyzer for near-continuous determination of dissolved iron in liquid media, utilizing a colorimetric measuring principle.
Liquiline System CA80HA
Liquid analysis › Analyzers for hardness, iron & more
Measuring Range: 0 to 80 mg/l (ppm) CaCO₃ · Ambient Temperature Range: +5 to +40 °C (41 to 104 °F) · Process Connection: Sample inlet: Plug-in connector (OD 4 mm) or hose barb (ID 1.6 mm). Dilution water: Hose barb (ID 3.2 mm). Outlet: Hose barb (ID 13 mm)
The Liquiline System CA80HA is a wet-chemical analyzer for near-continuous total hardness concentration determination using a colorimetric method.
Liquiline System CA80NO
Liquid analysis › Analyzers for hardness, iron & more
Measurement Wavelength: 568 nm · Cable Length: Max. 100 m (330 ft) · Output voltage: Max. 24 V
The Liquiline System CA80NO is a wet-chemical analyzer designed for continuous nitrite determination in liquid media using a colorimetric method.
Liquiline System CA80SI
Liquid analysis › Analyzers for hardness, iron & more
Signal characteristic: Linear · Fieldbus connection supply voltage: Not applicable · Test voltage: 500 V
The Liquiline System CA80SI is a wet-chemical analyzer for continuous silica concentration measurement in ultrapure and boiler feedwater.
Liquiline System CA80TN
Liquid analysis › Analyzers for hardness, iron & more
Ambient Temperature Range: +5 to +40 °C (41 to 104 °F) · Input Signal: 2 x 0/4 to 20 mA (optional), passive, potentially isolated · Load (Current Outputs): Max. 500 Ω
The Liquiline System CA80TN is a wet-chemical analyzer for near-continuous total nitrogen determination in liquid media using UV photometry.
Liquiline System CA80TP
Liquid analysis › Analyzers for hardness, iron & more
Output voltage: Max. 24 V
The Endress + Hauser Liquiline System CA80TP is a wet-chemical analyzer for continuous total phosphorus determination in liquid media, featuring a colorimetric measuring...
Memosens CCS55E
Liquid analysis › Analyzers for hardness, iron & more
At 10% of measuring range and 20 °C: 2 years · At 50% of measuring range and 20 °C: 1 year · Range of effectiveness: pH 5 to 10
The Memosens CCS55E is a digital sensor using Memosens technology for determining free bromine in seawater, process water, and pool applications.
Memosens CFS51
Liquid analysis › Analyzers for hardness, iron & more
Measuring range: 0 to 5,000 µg/l PAHphe · Process temperature range: –5 to 55 °C (20 to 130 °F) · Connection options: M12 plug or wire end ferrules for transmitter input
This Memosens CFS51 is a sensor for fluorescence measurement of polycyclic aromatic hydrocarbons (PAHs) in water, compliant with marine standards MEPC.259(68) and MEPC.
Memosens Wave CKI50
Liquid analysis › Process photometers
Ambient Temperature Range: –20 to 45 °C (–4 to 113 °F) · Process Pressure Range: 0.5 to 10 bar (7.3 to 145 psi) (absolute) · Process Connections: Varivent N DN50 - 125, immersion depth 68 mm (2.7 in)
The Memosens Wave CKI50 is an in-line process spectrometer used for analyzing liquids via VIS spectroscopy to detect and measure color, color variations, or color...
OUSAF11
Liquid analysis › Process photometers
Operating temperature range (sensor): 0 to 90 °C (32 to 190 °F) · Ambient temperature range: 0 to 55 °C (32 to 130 °F) · Measuring range: 0 to 3 AU (Absorbance Units) or 0 to 6 OD (Optical Density) depending on the optical path length
The OUSAF11 is an optical sensor for VIS/NIR absorption measurement used for interphase detection and solids measurement in various industries.
OUSAF12
Liquid analysis › Process photometers
Sensor (photometer): OUSAF12 · Wavelength: Broadband, NIR (780 nm+), 400 nm, 420 nm, 430 nm, 540 nm, 950 nm, and 1134 nm · Cable length: Maximum 100 m (330 ft)
The OUSAF12 is an optical sensor for measuring VIS/NIR absorption in liquid media, suitable for applications in the chemical, pharmaceutical, and food and beverage...
OUSAF21
Liquid analysis › Process photometers
Ambient temperature range: 0 to 55 °C (32 to 130 °F) · Connection: Via CUK80 cable set to Liquiline CM44P transmitter or OUK20 cable set to CVM40 transmitter · Cable connection ends material: Nickel-plated brass
The OUSAF21 is an optical sensor designed for measuring low color concentrations, such as APHA/Hazen and potassium permanganate, in applications including outgoing goods...
OUSAF22
Liquid analysis › Process photometers
Ambient temperature range: 0 to 55 °C (32 to 130 °F) · Power supply: Sensor connects to transmitter via CUK80 or OUK20 cable set · Cable connection ends: Nickel-plated brass
The OUSAF22 is an optical sensor for measuring color concentrations in visible light, suitable for color assurance and purity monitoring.
OUSAF44
Liquid analysis › Process photometers
Electrical connection: Via pre-terminated or labeled cable set CUK80 (for CM44P) or OUK40 (for CVM40) · Lamp connection: Requires connection via a certified junction box for hazardous areas · Power supply: Provided by associated transmitter via cable set
The OUSAF44 is an optical sensor designed for UV absorption measurement in process liquids, suitable for applications like protein concentration and organic compound...
OUSAF46
Liquid analysis › Process photometers
Wavelength: Discrete wavelength combination at 254/280, 280/295, 280/302 or 280/313 nm · Lamp voltage: 10.0 ± 0.1 V · Ambient temperature: 0 to 55 °C (32 to 131 °F)
The OUSAF46 is an optical sensor used with the OUA260 flow assembly for measuring UV absorption in process liquids.
OUSBT66
Liquid analysis › Process photometers
Selection cues: measuring range · accuracy · output signal and process connection
The OUSBT66 is a sensor from Endress+Hauser Liquid Analysis.
OUSTF10
Liquid analysis › Process photometers
Ambient temperature range: 0 to 55 °C (32 to 130 °F) · Power supply: Sensor is connected to a transmitter (e.g., Liquiline CM44P or CVM40) using cable set CUK80 (or OUK20 for CVM40). Cable set must be ordered separately · Detector signals (scattered light and transmitted light): S+, S-
The Endress + Hauser OUSTF10 is an optical sensor using the scattered light method for measuring turbidity and undissolved solids in process liquids.
Viomax CAS51D
Liquid analysis › Process photometers
Ambient Temperature Range: –20 to 60 °C (–4 to 140 °F) · Process Temperature Range: 5 to 50 °C (41 to 122 °F) · Process Pressure Range: 0.5 to 10 bar (7.3 to 145 psi) absolute
The Viomax CAS51D is a photometric sensor used for measuring spectral absorption coefficient (SAC) or nitrate content in water.
Memosens Wave CAS80E
Liquid analysis › Process photometers
Ambient temperature range: –20 to 60 °C (–4 to 140 °F) · Process temperature range: 0 to 50 °C (32 to 122 °F) · Process pressure range: 0.5 to 10 bar (7.3 to 145 psi) (absolute)
The Memosens Wave CAS80E is a UV-VIS spectrometer for water analysis, measuring parameters like SAC, TOCeq, and turbidity.
Liquiline System CAT17
Liquid analysis › Automatic water samples
Ambient temperature range: 0 to 40 °C (32 to 104 °F) · Supply voltage: 220 V AC, 50 Hz · Suction height of peristaltic pump: Max. 3 m (10 ft)
The Liquiline System CAT17 is an automatic sample preparation system designed for supplying filtered samples from pressure pipes to process measuring devices.
Liquiline System CAT810
Liquid analysis › Automatic water samples
Ambient temperature range: +5 to +40 °C (41 to 104 °F) · Supply voltage: 100 to 120 V AC / 200 to 240 V AC, 50 or 60 Hz · Power consumption of optional cleaning valve: Max. 30 VA
The Liquiline System CAT810 is an automatic sample preparation system designed for filtered sample delivery to process measuring devices from pressure pipes.
Liquiline System CAT820
Liquid analysis › Automatic water samples
Power supply: 24 V from CA71 analyzer or other 12 W power supply · Storage temperature: -20 to +60 °C (-4 to 140 °F) · Degree of protection: IP67
The Liquiline System CAT820 is an automatic sample conditioning system designed for supplying filtered samples to process measuring devices in wastewater treatment and...
Liquiline System CAT860
Liquid analysis › Automatic water samples
Suction height of peristaltic pump: Max. 5 m (16 ft) · Hose length, filter to pump: Max. 5 m (16 ft) · Hose length, pump to analyzer: Max. 30 m (98 ft)
The Liquiline System CAT860 is an automatic sample conditioning system designed for preparing aqueous samples from wastewater treatment plants for process analyzers.
Liquiport CSP44
Liquid analysis › Automatic water samples
Measuring range: -30 to 70 °C (-20 to 160 °F) · Ambient temperature range: 0 to 40 °C (32 to 104 °F). Do not install in high temperatures or direct sunlight · Intake speed as per Ö 5893, US EPA: approx. 0.6 m/s to 1.0 m/s for suction heights of 3.3 m to 6.6 m
The Liquiport CSP44 is an automatic sampler for liquid media with an integrated multi-parameter controller, featuring two measuring channels and optional digital Memosens...
Liquistation CSF28
Liquid analysis › Automatic water samples
Ambient temperature range (with cooling module): -20 to 40 °C (0 to 104 °F) · Medium temperature range: 2 to 50 °C (36 to 122 °F) · Process pressure range: Unpressurized, open channel
The Liquistation CSF28 is an automatic stationary sampler designed for municipal and industrial wastewater treatment plants and authorities.
Liquistation CSF34
Liquid analysis › Automatic water samples
Ambient temperature range: -30 to 50 °C (-20 to 120 °F) · Process medium temperature range: 2 to 50 °C (36 to 122 °F) · Version with 24V power supply: 240 W
The Liquistation CSF34 is an automatic stationary sampler for liquid media, featuring integrated controller with up to four Memosens channels for applications in...
Liquistation CSF39
Liquid analysis › Automatic water samples
Sample temperature range: 2 to 20 °C (36 to 68 °F) · Protocols supported: HART, Modbus RS485, Modbus TCP, PROFINET, EtherNet/IP · Permitted cable diameter: M20 (7 to 13 mm), M25 (9 to 17 mm)
The Liquistation CSF39 is an automatic stationary sampler for liquid media with self-draining and integrated controller capabilities.
Liquistation CSF48
Liquid analysis › Automatic water samples
Medium temperature range: 2 to 50 °C · Process pressure range: Unpressurized open channel, max. 0.8 bar piping, max. 6 bar for sampling assembly · Intake speed: > 0.5 m/s (for ≤ 13 mm ID) or > 0.6 m/s (for 10 mm ID), as per relevant standards
The Liquistation CSF48 is a stationary liquid sampler for wastewater treatment and industrial process monitoring, capable of automated removal, distribution, and...
Ceragel CPS72
Liquid analysis › ORP sensors & transmitters
ORP Measuring Range: -1500 to 1500 mV · Process Connection: Pg 13.5 thread · Process Pressure (absolute): 0.8 to 11 bar (12 to 160 psi)
The Ceragel CPS72 is an ORP electrode designed for hygienic, sterile, and process applications with poison-resistant reference technology.
Memosens CPF82E
Liquid analysis › ORP sensors & transmitters
Temperature Range: Suitable for measurements within a temperature range of 0 to 80 °C (32 to 176 °F) · Ambient Temperature Range: Storage temperature is 0 to 50 °C (32 to 122 °F). (Note: Do not use below 0 °C due to frost risk) · Process Temperature Range: 0 to 80 °C (32 to 176 °F)
The Memosens CPF82E is an ORP sensor utilizing Memosens 2.0 technology for applications in mining and industrial water treatment.
Memosens CPS12E
Liquid analysis › ORP sensors & transmitters
Measuring range: –1 500 to 1 500 mV · Ambient temperature range: –15 °C (5 °F) to 135 °C (275 °F) (Operating), 0 to 50 °C (32 to 122 °F) (Storage) · Process temperature range: –15 to 135 °C (5 to 275 °F)
The Memosens CPS12E is an ORP sensor for standard applications in process technology and environmental engineering, featuring Memosens 2.0 technology for safe, digital...
Memosens CPS42E
Liquid analysis › ORP sensors & transmitters
ORP Measurement Range: -1500 to 1500 mV · Process Connection: Pg 13.5 · Power Supply: Via Memosens data cable (CYK10 or CYK20) connected to a Memosens transmitter
The Memosens CPS42E is a digital ORP sensor utilizing Memosens 2.0 technology for process applications in industries such as chemical and power generation.
Memosens CPS62E
Liquid analysis › ORP sensors & transmitters
Selection cues: measuring range · accuracy · output signal and process connection
The Memosens CPS62E is a pH sensor designed for challenging applications.
Memosens CPS72E
Liquid analysis › ORP sensors & transmitters
Process Temperature Range: 0 to 140 °C (32 to 284 °F) · Process Pressure Range: 0.8 to 14 bar (11.6 to 203 psi) (absolute) · Process Connections: Pg 13.5
The Endress + Hauser Memosens CPS72E is a digital ORP sensor designed for chemical process applications with rapidly changing values and high poison concentrations.
Memosens CPS92E
Liquid analysis › ORP sensors & transmitters
Measuring Range: –1500 to 1500 mV (ORP) · Ambient Temperature Range: 0 to 50 °C (32 to 122 °F). Do not use below freezing temperatures · Process Temperature Range: 0 to 110 °C (32 to 230 °F)
The Memosens CPS92E is an ORP sensor designed for use in heavily polluted media, featuring an open aperture and low maintenance through gel filling.
Orbisint CPS12-CPS12D-CPS13
Liquid analysis › ORP sensors & transmitters
Measuring range: -1500 ... 1500 mV · Process connection: Pg 13.5 · Multiple lengths: Offered in 120 mm, 225 mm, and 360 mm
Orbisint CPS12, CPS12D, and CPS13 are ORP electrodes with Memosens technology for process and environmental applications, including water treatment.
CCS51
Liquid analysis › Chlorine sensors & transmitters
At 50 % of measuring range and 20 °C: 1 year · At 10 % of measuring range and 20 °C: 2 years · Sensor cable length: Maximum 3 m (9.8 ft)
The Endress+Hauser CCS51 is an amperometric sensor for measuring free chlorine in drinking water, food industry, utilities, and pool water.
CCS120
Liquid analysis › Chlorine sensors & transmitters
Measuring range: 0.1 ... 10 mg/l · pH range: 5.5 ... 9.5 · Conductivity range: 0.03 ... 40 mS/cm
The Endress + Hauser CCS120 is an amperometric sensor designed for measuring total chlorine in drinking water, pool water, service water, and wastewater treatment...
Liquisys M CCM223-253
Liquid analysis › Chlorine sensors & transmitters
Display Range (Temperature): 0 to 50 °C (32 to 122 °F) · pH Measuring Range (Display): pH 3.5 to 9.5 · ORP Measuring Range (Display): 0 to 1500 mV
This transmitter is designed for measuring free chlorine, chlorine dioxide, and total chlorine in various water treatment applications.
Memosens CCS51E
Liquid analysis › Chlorine sensors & transmitters
At 10% of measuring range and 20 °C: 2 years · At 50% of measuring range and 20 °C: 1 year · Range of effectiveness: pH 4 to 9
The Memosens CCS51E is a digital sensor utilizing Memosens technology for the amperometric measurement of free chlorine in drinking water, utilities, and process...
Memosens CCS53E
Liquid analysis › Chlorine sensors & transmitters
Ambient temperature range: –20 to 60 °C (–4 to 140 °F) · Process temperature range: 0 to 55 °C (32 to 130 °F), non-freezing · pH range: 4 to 9
This Memosens CCS53E is a digital sensor utilizing Memosens technology for total chlorine measurement in various water applications.
CA76NA
Liquid analysis › Laboratory instruments
Ambient temperature range: 5 to 45 °C (41 to 113 °F) · Sample temperature range: +10 to +40 °C (+50 to +104 °F) · Signal encoding: EIA/TIA-485, PROFIBUS DP-compliant acc. to IEC 61158
The Endress + Hauser CA76NA is a potentiometric analyzer designed for monitoring sodium ion concentration in various water applications, including power stations and...
Chemoclean CYR10B
Liquid analysis › Laboratory instruments
Ambient temperature range: –5 to +40 °C · Storage temperature range: –40 to +60 °C · Motive water flow range: 2 to 10 l/min
The Chemoclean CYR10B is a cleaning injector with a dosing function for universal use in automatic sensor cleaning systems.
CleanFit Control CYC25
Liquid analysis › Laboratory instruments
Ambient temperature range: -10 to +45 °C (+10 to +113 °F) · Signal line, transmitter - Cleanfit Control: Supplied with CYC25 · Hose connection sets: Available in PVDF or 1.4404 (AISI 316L) for DN12 and DN16
The CleanFit Control CYC25 is an automatic cleaning unit for sensors installed in retractable assemblies, designed for various industrial sectors including water and...
CPY3
Liquid analysis › Laboratory instruments
Signal word: Danger · sulphuric acid (CAS: 7664-93-9): PEL 1 mg/m³, REL 1 mg/m³, TLV 0.2 mg/m³ (as thoracic fraction, A2) · pH-value at 20 °C (68 °F): <2
This Endress + Hauser CPY3 is a laboratory chemical buffer solution for pH measurement.
CYM17
Liquid analysis › Laboratory instruments
Signal Integrity: The CYM17 brings Memosens sensor technology to laboratory fermenters, providing maximum signal integrity and reliable measured values · Output Signal: The output signal of the converter corresponds to that of a conventional analog pH or oxygen sensor
The Endress + Hauser CYM17 is a Memosens analog converter designed for digital pH and oxygen sensors in laboratory fermenters.
Turbimax CUA252
Liquid analysis › Turbidity sensors & transmitters
Ambient temperature range: 0 to 55 °C (32 to 131 °F) · Process temperature range: 0 to 50 °C (32 to 122 °F) · Process pressure range: 0 to 6 bar (0 to 87 psi)
The Turbimax CUA252 is a flow assembly designed for installing turbidity sensors in pipelines for water treatment applications.
Turbimax CUA262
Liquid analysis › Turbidity sensors & transmitters
Ambient temperature range: 0 to 60 °C (32 to 140 °F) · Process temperature range: 0 to 90 °C (32 to 194 °F) · Process pressure range: 0 to 10 bar (0 to 145 psi)
The Flowfit CUA262 is a stainless steel flow assembly designed for direct installation of the CUS52D turbidity sensor in process water skids and closed pipe systems.
Turbimax CUS51D
Liquid analysis › Turbidity sensors & transmitters
Ambient Temperature Range: –20 to 60 °C (–4 to 140 °F) · Process Temperature Range: –5 to 50 °C (23 to 122 °F); up to 80 °C (176 °F) for short periods (1 h) · Process Pressure Range: 0.5 to 10 bar (7.3 to 145 psi) absolute
The Turbimax CUS51D is a versatile sensor designed for measuring turbidity and solids content in wastewater treatment applications.
Turbimax CUS71D
Liquid analysis › Turbidity sensors & transmitters
Measuring range: 0.3 to 10 m (1 to 32 ft) · Process temperature range: 1 to 50 °C (34 to 122 °F) · Process connections: G1" and NPT ¾"
The Turbimax CUS71D is an ultrasonic interface sensor for accurate level measurement in water and wastewater treatment processes.
CCS58E
Liquid analysis › Nutrient analyzers & sensors
Measuring Range (Ozone): 0 to 2 mg/l (ppm). Not suitable for checking the absence of ozone · Temperature: 15 °C (59 °F) ±2 °C (±3.6 °F) · pH Value: pH 7.2 ±0.2
The Endress + Hauser CCS58E is a digital ozone sensor utilizing amperometric measurement with Memosens technology for wastewater, drinking water, and process water...
ISEmax CAS40D
Liquid analysis › Nutrient analyzers & sensors
Power Supply Options: 230 V or 115 V · Maximum Cable Length: 100 m (328 ft) · Pressure: 3 to 3.5 bar (45 to 50 psi)
The ISEmax CAS40D is an ion-selective sensor designed for continuous online measurement of nutrient parameters like ammonium and nitrate in municipal wastewater treatment...
TOC Analyzer CA78
Liquid analysis › TOC, COD & SAC analyzers
Ambient temperature range: 10 to 45 °C (50 to 113 °F) · Output signal (Measuring channel 1): 0/4 to 20 mA, galvanically isolated · Output signal (Measuring channel 2, optional): 0/4 to 20 mA, galvanically isolated
This Endress + Hauser TOC Analyzer CA78 utilizes UV digestion to measure total organic carbon in ultrapure water and features a stainless steel housing with an 8"...
TOC Analyzer CA79
Liquid analysis › TOC, COD & SAC analyzers
Ambient temperature range: 10 to 45 °C (50 to 113 °F) · Output signal (Measuring channel 1): 0/4 to 20 mA, galvanically isolated · Output signal (Measuring channel 2, optional): 0/4 to 20 mA, galvanically isolated
The Endress+Hauser CA79 is a TOC analyzer designed for ultrapure water applications with a conductivity less than 2 µS/cm.
TOCII CA72TOC
Liquid analysis › TOC, COD & SAC analyzers
Ambient temperature range: +5 to 35 °C (41 to 95 °F) · Medium temperature range: 4 to 40 °C (39 to 104 °F) · 8 signal inputs: 24 V DC, active, load max. 500 Ω
The TOCII CA72TOC is an analyzer designed for online measurement of Total Organic Carbon (TOC) in aqueous media using thermic catalytic combustion.
Cerabar PMC11
Pressure measurement › Absolute and gauge pressure measurement
PMC21/PMP21 (Hazardous areas): –40 to +70 °C (–40 to +158 °F) · 4 to 20 mA output: 10 to 30 V DC · 0 to 10 V output: 12 to 30 V DC
The Endress + Hauser Cerabar PMC11 is a pressure transducer for measuring gauge pressure in gases, vapors, liquids, and dust.
Cerabar M PMC51
Pressure measurement › Absolute and gauge pressure measurement
Version XSJ (prepared for diaphragm seal mount): Welding recommendation for fillet weld: 1 mm depth, 16 mm outer diameter, using WIG method · Supply voltage: 11.5 to 45 V DC (35 V DC for versions with plug-in connector) · Supply voltage and internal ground: 0.5 to 2.5 mm² (20 to 14 AWG)
The Cerabar M PMC51 is an analog process transmitter designed for pressure and level measurement.
Cerabar M PMC51B
Pressure measurement › Absolute and gauge pressure measurement
Selection cues: measuring range · accuracy · output signal and process connection
The Endress + Hauser Cerabar M PMC51B is a transmitter for measuring hydraulic pressure.
Cerabar S PMC71
Pressure measurement › Absolute and gauge pressure measurement
Process Connections: Various options available for PMC71, PMP71, and PMP75, including internal and flush process membranes, and hygienic connections · Ambient Temperature Range: Not explicitly detailed in the extract, but noted as a factor for Wireless HART minimum operating voltage · Storage Temperature Range: Not specified in the extract
The Endress + Hauser Cerabar S PMC71 is a pressure transmitter for absolute and gauge pressure measurements in gases, steams, and liquids.
Cerabar M PMC71B
Pressure measurement › Absolute and gauge pressure measurement
Pressure measuring ranges: up to 40 bar (600 psi) · Process pressure range: Up to 40 bar (600 psi) · Accuracy: up to ±0.025%
The Endress + Hauser Cerabar PMC71B is a robust transmitter for process pressure and level measurement in liquids or gases, featuring a ceramic process membrane and a...
Cerabar PMP23
Pressure measurement › Absolute and gauge pressure measurement
Process Temperature Range (at process connection): –10 to +100 °C (+14 to +212 °F), with a maximum of +135 °C (+275 °F) for one hour during SIP cleaning · Storage Temperature Range: –40 to +85 °C (–40 to +185 °F) · Signal Range (4 to 20 mA): 3.8 to 20.5 mA
The Endress + Hauser Cerabar PMP23 is a pressure transducer for measuring absolute and gauge pressure in gases, vapors, liquids, and dust, suitable for hygienic...
Cerabar PMP43
Pressure measurement › Absolute and gauge pressure measurement
Pressure measuring range: up to 100 bar (1500 psi) · Accuracy: up to ± 0.075 % · Output Signal: 2-wire 4 to 20 mA
The Cerabar PMP43 is a compact digital transmitter designed for reliable pressure and hydrostatic level measurement.
Cerabar PMP50
Pressure measurement › Absolute and gauge pressure measurement
Pressure measuring ranges: up to 400 bar (6,000 psi) · Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F). With color display, limitations apply above +60 °C (+140 °F) · Accuracy: up to ±0.055%
The Endress + Hauser Cerabar PMP50 is a pressure transmitter with a metal process membrane, suitable for absolute and gauge pressure measurements up to 400 bar.
Cerabar M PMP51
Pressure measurement › Absolute and gauge pressure measurement
Ambient Temperature Range: See the official PDF for details · Storage Temperature Range: See the official PDF for details · Without diaphragm seals: up to 130 °C (266 °F) for a maximum of 60 minutes; also listed as 150 °C (302 °F)
The Endress + Hauser Cerabar M PMP51 is a metallic process membrane transmitter for absolute and gauge pressure measurement in gases, steams, and liquids.
Cerabar M PMP51B
Pressure measurement › Absolute and gauge pressure measurement
Pressure measuring ranges: up to 400 bar (6,000 psi) · Accuracy: up to ±0.055% · Ambient temperature range: See the official PDF for exact tabulated values
The Cerabar M PMP51B is a digital pressure transmitter with a metallic process membrane for measuring absolute or gauge pressure in liquids or gases up to 400 bar.
Cerabar M PMP71B
Pressure measurement › Absolute and gauge pressure measurement
Pressure Measuring Ranges: Up to 700 bar (10,500 psi) · Accuracy: Up to ±0.025% · Reference Accuracy: Varies by measuring cell and turn down ratio (TD). For platinum measuring cells, accuracy can be as high as ±0.025%
The Cerabar M PMP71B is a digital pressure transmitter for process and level measurement in liquids or gases.
Ceraphant PTC31B
Pressure measurement › Absolute and gauge pressure measurement
Customized measuring ranges with a turn down ratio up to 5: 1 · Seal options influence temperature range (e.g., FKM: –20 to +100 °C) · Reference accuracy: up to 0.3%
The Endress+Hauser Ceraphant PTC31B is a pressure switch designed for safe measurement and monitoring of absolute and gauge pressure in gases, vapors, liquids, and dust.
Ceraphant PTP33B
Pressure measurement › Absolute and gauge pressure measurement
Sensor measuring ranges: Up to 40 bar (600 psi) · Process temperature range (for metallic process isolating diaphragm): –10 to +100 °C (+14 to +212 °F) · Storage temperature range: –40 to +85 °C (–40 to +185 °F)
The Ceraphant PTP33B is a versatile pressure switch for measuring absolute and gauge pressure in gases, liquids, vapors, and dust, suitable for hygienic applications.
Waterpilot FMX11
Pressure measurement › Absolute and gauge pressure measurement
Signal range: 2 to 22 mA · Sensor measuring range ≥ 400 mbar: ≤ ±0.35 % · Sensor measuring range < 400 mbar: ≤ ±0.50 %
The Waterpilot FMX11 is a hydrostatic level transmitter designed for fresh water applications, including wells, rivers, and water towers.
Waterpilot FMX21
Pressure measurement › Absolute and gauge pressure measurement
Ambient temperature range: –10 to +70 °C (+14 to +158 °F) · Signal range: 3.8 to 20.5 mA · Storage temperature range: Not specified
The Waterpilot FMX21 is a compact pressure transmitter designed for hydrostatic level measurement in various water applications.
Deltatop DP61D
Pressure measurement › Differential pressure measurement
Measuring Range: -200 °C to +600 °C (-328 °F to +1112 °F) · Output Signals: 4...20mA, 4...20mA HART, PROFIBUS PA, or Pt100 (4-wire) · Process Connection: Options include cutting ring, flange (EN/ANSI), and Flowtap versions for in-process Pitot tube exchange. Pressure ratings range from PN6 to PN250 / Cl.150 to Cl.1500
The Endress + Hauser Deltatop DP61D is a differential pressure flow measurement system utilizing Pitot tubes and Deltabar transmitters for gases, steam, and liquids.
Deltapilot M FMB50
Pressure measurement › Differential pressure measurement
High reference accuracy: ±0.2%, optionally ±0.1% · Other types of protection / Devices without certificate: 11.5 to 45 V DC (35 V DC for versions with plug-in connector) · Ambient temperature: +21 to +33 °C (+70 to +91 °F)
The Deltapilot M FMB50 is a pressure transmitter featuring a condensate-resistant CONTITE™ measuring cell for reliable hydrostatic pressure measurement in liquids and...
Deltabar S FMD71 electronic dp
Pressure measurement › Differential pressure measurement
Signal Range: 3.8 to 20.5 mA · Output Signal: 4 to 20 mA with superimposed digital communication protocol HART 6.0, 2-wire · Process Connections: Various internal and flush membrane options available for FMD71 and FMD72. Refer to official PDF for detailed diagrams and specifications
The Deltabar S FMD71 is an electronic differential pressure transmitter with ceramic or metallic measuring cells, designed for level, volume, or mass measurement in...
Deltabar S FMD77
Pressure measurement › Differential pressure measurement
Minimum static pressure: 0.1 mbarabs (0.0015 psiabs) · Minimum starting voltage: 11.5 V (default) or 10.5 V · Nominal functioning DC voltage: 600 V
The Deltabar S FMD77 is a differential pressure transmitter with metallic measuring cells for gases, vapors, and liquids.
Deltabar M PMD55
Pressure measurement › Differential pressure measurement
Current output: 1 μA
The Deltabar M PMD55 is a differential pressure transmitter with a metallic measuring cell, suitable for flow, level, and differential pressure monitoring in gases,...
Deltabar M PMD55B
Pressure measurement › Differential pressure measurement
Pressure measuring ranges: up to 40 bar (600 psi) · Values range from ±0.055% to ±0.1% for TD 1: 1, with formulas provided for TD > 1:1 · Accuracy: up to ±0.055%
The Deltabar M PMD55B is a digital differential pressure transmitter designed for applications with measuring ranges up to 40 bar.
Deltabar M PMD75B
Pressure measurement › Differential pressure measurement
Pressure measuring ranges: up to 250 bar (gauge and absolute), and 40 bar (differential pressure) · Maximum measuring range: Up to 160 bar (2400 psi) or 250 bar (3750 psi) · Accuracy: up to ±0.035%
The Deltabar PMD75B is a digital differential pressure transmitter featuring a metal process membrane for various pressure measuring applications.
Deltabar S PMD78B
Pressure measurement › Differential pressure measurement
Pressure measuring ranges: up to 40 bar (600 psi) · Accuracy: up to ±0.075% · Process temperatures: up to 400 °C (752 °F) with diaphragm seal
The Deltabar S PMD78B is a digital differential pressure transmitter with a metallic process membrane used for measuring differential pressure, level, and flow.
RTD T13, T14, T15
temperature measurement › Industrial thermometers
Measuring Range: -200 to 600 °C (–328 to 1,112 °F) · T13/T14/T15 (Low Temperature Range): –50 to 200 °C (–58 to 392 °F) · T13/T14/T15 (High Temperature Range): –200 to 600 °C (–328 to 1,112 °F)
Endress + Hauser RTD T13, T14, and T15 are explosion-proof RTD assemblies designed for heavy-duty applications in process industries.
RTD T53, T54, T55
temperature measurement › Industrial thermometers
Analog output: 4 to 20 mA · Head mounted transmitter TMT18x (single input): 11.5 to 35 V (non-Ex), 11.5 to 30 V (Ex) · Maximum continuous voltage (rated voltage): UC = 42 VDC
The Endress+Hauser T53, T54, and T55 are explosion-proof thermocouple assemblies for process industries, available with spring-loaded inserts and various enclosure...
RTD TH11, TH12
temperature measurement › Industrial thermometers
Low range thin film RTDs: -50 to 200 °C (-58 to 392 °F). Constructed with silver plated copper internal leads and PTFE wire insulation · High range RTDs: -200 to 600 °C (-328 to 1112 °F). Constructed with nickel internal leads inside swaged MgO insulated cable · Low temperature range (thin film): TH11/TH12 models can cover -50 to 200 °C (-58 to 392 °F)
The RTD TH11 and TH12 are general-purpose resistance temperature detectors for process and laboratory applications, utilizing a Pt100 sensor according to IEC 60751.
RTD TH13, TH14, TH15
temperature measurement › Industrial thermometers
TH13, TH14, TH15 (Low temperature range): –50 to 200 °C (–58 to 392 °F) · TH13, TH14, TH15 (High temperature range): –200 to 600 °C (–328 to 1 112 °F) · Accuracy: RTD sensors correspond to IEC 60751 classes AA, A, and B. Tolerances vary based on class, sensor type (TF, WW, StrongSens), and temperature range
The Endress + Hauser RTD TH13, TH14, and TH15 are platinum resistance temperature detector assemblies for industrial process measurement.
iTherm Moduline TM101
temperature measurement › Industrial thermometers
Measuring range: –50 to +650 °C (–58 to +1 202 °F) · Degree of protection: up to IP 68 · Analog output: 4 to 20 mA, HART®
The iTherm Moduline TM101 is a versatile RTD or thermocouple thermometer designed for direct process installation, suitable for non-hazardous areas within a -50 to +1100...
iTherm Moduline TM111
temperature measurement › Industrial thermometers
Measuring range: –200 to +1 100 °C (–328 to +2 012 °F) · Pressure range: Up to 75 bar (1 088 psi) to +200 °C (+392 °F) for standard thin-film and iTHERM QuickSens Pt100 sensors. For other sensor types, up to 50 bar (725 psi) to +400 °C (+752 °F) · Power supply: Details vary based on the transmitter type. Typically supplied via the 2-wire loop or fieldbus connection
The Endress + Hauser iTherm Moduline TM111 is a robust, modular thermometer designed for direct installation in a wide temperature range of -200 to +1100 °C.
iTherm Moduline TM112
temperature measurement › Industrial thermometers
Measuring range: –200 to +1 100 °C (–328 to +2 012 °F) · Pressure range: up to 75 bar (1 088 psi) · Process Temperature Range: –200 to +1 100 °C (–328 to +2 012 °F) (depends on sensor/material)
The Endress+Hauser iTherm Moduline TM112 is a versatile industrial modular thermometer for universal use.
iTherm Moduline TM121
temperature measurement › Industrial thermometers
Measuring range: –50 to +650 °C (–58 to +2 012 °F) · Pressure range: up to 50 bar (725 psi) · Degree of protection: up to IP 68
The Endress + Hauser iTHERM Moduline TM121 is a metric thermometer designed for standard applications with replaceable inserts.
iTherm Moduline TM131
temperature measurement › Industrial thermometers
Process temperature range: Max. –200 to +1,100 °C (–328 to +2,012 °F), dependent on sensor type and thermowell material · Process connection: Various threaded, flanged, and compression fittings · Terminal head with transmitter: –40 to +85 °C (–40 to +185 °F)
The iTHERM Moduline TM131 is a modular RTD or TC thermometer for universal industrial use, offering temperature measurements from -200 to 1,100 °C and resisting...
iTherm Moduline TM151
temperature measurement › Industrial thermometers
Measuring range: –200 to +1 100 °C (–328 to +2 012 °F) · Process Connection: Various options including threads, flanges (EN or ASME), and socket weld · Analog output: 4 to 20 mA, HART® (optional SIL transmitter available)
The iTHERM Moduline TM151 is a modular RTD or TC thermometer for universal industrial applications with a measuring range up to 1100 °C and pressure up to 500 bar.
iTherm Moduline TM152
temperature measurement › Industrial thermometers
Pressure range: up to 500 bar (7 252 psi) · Temperature range: –40 to +80 °C (–40 to +176 °F) · Process temperature range: –200 to +1 100 °C (–328 to +2 012 °F). For fast-response thermowell: –200 to +400 °C
The Endress + Hauser iTherm Moduline TM152 is an industrial modular thermometer for universal use with a measuring range of up to 1,100 °C and pressures up to 500 bar.
iTherm Compactline TM311
temperature measurement › Industrial thermometers
Measuring range: –50 to +200 °C (–58 to +392 °F) · Pressure range: Up to 50 bar (725 psi) · Ambient temperature range: –40 to +85 °C (–40 to +185 °F)
This Endress + Hauser iTHERM Compactline TM311 is a compact RTD thermometer designed for universal use in hygienic and aseptic industrial applications.
iTherm Moduline TM401
temperature measurement › Industrial thermometers
Measuring Range: –50 to +200 °C (–58 to +392 °F) · Pressure Range: Up to 50 bar (725 psi) - Note: Maximum pressure is dependent on the specific process connection · Sanitary Connection (DIN 11851): Available for DN25, DN32, DN40, DN50. Maximum pressure up to 40 bar (580 psi) for DN25-DN40, and 25 bar (363 psi) for DN50
The Endress + Hauser iTherm Moduline TM401 is a resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
iTherm Moduline TM411
temperature measurement › Industrial thermometers
Measuring range: –200 to +600 °C (–328 to +1 112 °F) · Pressure range: Up to 50 bar (725 psi) · Pt100 wire wound, extended measuring range: –200 to +600 °C (–328 to +1 112 °F)
The iTHERM Moduline TM411 is a modular resistance thermometer engineered for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
iTherm Moduline TST434B
temperature measurement › Industrial thermometers
Maximum measuring range: –50 to +150 °C (–58 to +302 °F) · Measuring range: Maximum –50 to +150 °C (–58 to +302 °F) according to IEC 60751, depending on configuration · Process pressure range: Maximum static process pressure: 1 bar (14.5 PSI) at 20 °C (68 °F)
The iTHERM Moduline TST434B is a modular resistance thermometer for ambient temperature measurement, available with or without Endress+Hauser iTEMP temperature...
Omnigrad TST434
temperature measurement › Industrial thermometers
Allowed temperature (without transmitter): -30°C to +100°C · Allowed temperature (with transmitter): -20°C to +80°C · Standard diameter: 8 mm
The Omnigrad TST434 is an RTD thermometer designed for medium-duty applications in building automation, including outdoor ambient and wet environments.
RTD TST602
temperature measurement › Industrial thermometers
Connection Method: Selectable 3-wire or 4-wire · Accuracy Classes (IEC 60751): A, AA, B · Temperature Coefficient (α): 0.003851 °C⁻¹
The Endress + Hauser TST602 is an RTD assembly designed for easy attachment to pipe or vessel surfaces for temperature measurement.
Omnigrad TA550
temperature measurement › Thermowells
Nominal length (A) range: 130 ÷ 1000 mm · Process connection type: Threaded (AA - 3/4" NPT), various ANSI flange options (CD, CH, CK, CP, CV, CX) · Standard extension length: 70 mm
The Omnigrad TA550 is a heavy-duty industrial thermowell manufactured from drilled round bar stock, suitable for resistance and thermocouple thermometers.
Omnigrad TA555
temperature measurement › Thermowells
Standard extension length (T): 75 mm · Standard bore diameter: 6.5 mm, 7 mm, or 8 mm · Standard material: AISI316/W.1.4401, AISI316L/W.1.4404
Designed for use with resistance and thermocouple thermometers, mainly in heavy duty applications.
Omnigrad TA556
temperature measurement › Thermowells
Process connection type: Various ANSI flanged slip-on options (1", 1 1/2", 2" in different pressure classes and types) and a 'none' option for 1" NPT. Special versions are available · Standard extension length: 100 mm · Standard bore diameter: 10 or 14 mm
The Endress + Hauser Omnigrad TA556 is a heavy-duty industrial thermowell manufactured from drilled round bar stock for general-purpose use with resistance and...
Omnigrad TA557
temperature measurement › Thermowells
Process Connection: Various ANSI slip-on flange options (e.g., 1" ANSI 300 RF, 1 1/2" 150 RF, 1 1/2" 300 RF, 1 1/2" ANSI 600 RTJ, 2" ANSI 300 RF, 2" ANSI 300 RTJ) and "none" (1" NPT) · Round Bar Outer Diameter (O.D.): 35 mm · Standard Extension Length: 100 mm
Omnigrad TA557 is part of this brand portfolio and is best compared by application duty, interface format, and operating conditions.
Omnigrad TA560
temperature measurement › Thermowells
Connection to thermometer: Threaded, 1/2" NPT - female · Outside Diameter (O.D.): < 22 mm · Standard bore diameter: 6.5 or 10 mm
The Omnigrad TA560 is a heavy-duty, general-purpose industrial thermowell designed for use with resistance and thermocouple thermometers.
Omnigrad TA562
temperature measurement › Thermowells
Process connection: Threaded · Connection to thermometer: Threaded · Extension length, immersion length, and reduced length: Can be chosen according to process requirements
The Omnigrad TA562 is a heavy-duty, general-purpose industrial thermowell manufactured from hexagonal bar stock.
Omnigrad TA566
temperature measurement › Thermowells
Connection to thermometer: Threaded, 1/2" NPT - female · Outside diameter (O.D.): < 28 mm · Standard bore diameter: 6.5 mm or 13 mm
The Omnigrad TA566 is a heavy-duty, general-purpose thermowell manufactured from hexagonal bar stock with a 1" NPT threaded process connection.
Omnigrad TA570, TA571, TA572
temperature measurement › Thermowells
Process temperature range: For maximum operating temperatures, see the 'Material' section · Immersion length (U): Examples include 150 mm (5.9 in), 225 mm (8.9 in), 270 mm (10.6 in), 400 mm (15.7 in), 100 mm (3.94 in), and customer-specific lengths · Extension diameter (⌀D1): Ranges from 25 mm (0.98 in) to 49 mm (1.9 in) depending on the model
Omnigrad TA570, TA571, TA572 is an online instrument or sensor product for water systems, best compared by measured parameter, range, mounting style, and signal interface.
Omnigrad TA575, TA576
temperature measurement › Thermowells
Process Temperature Range: Refer to the 'Material' section for maximum operating temperatures · Thermometer Connection Thread: Standard is ½" NPT, ½" NPSM, or ½" NPSC · Screw-in Length: 8 mm (0.31 in)
The Omnigrad TA575 and TA576 are heavy-duty industrial thermowells manufactured from round barstock for general-purpose temperature measurement.
Omnigrad TA730
temperature measurement › Thermowells
Selection cues: measuring range · accuracy · output signal and process connection
The Omnigrad TA730 is a protective sheath for temperature measurement instruments.
Omnigrad TW251
temperature measurement › Thermowells
Maximum process temperature (well stem): 600°C · Inner diameter: Accommodates probes with a 6 mm diameter (straight execution). Tapered and reduced executions can house inserts with a 3 mm tip · Materials (Wetted parts): SS 316L/1.4404
The Endress + Hauser Omnigrad TW251 is a general industrial and hygienic thermowell designed for temperature measurement with integrated compression fittings.
Omnigrad M TW11
temperature measurement › Thermowells
Process Connection: Threaded · Thermowell Pipe Diameter: 9 mm, 11 mm, or 12 mm · Weight: 0.5 to 2.0 Kg for standard options
The Omnigrad M TW11 is a pipe thermowell with a threaded process connection, designed for fine chemicals and general industrial applications.
Omnigrad M TW15
temperature measurement › Thermowells
Thread neck tube connection (T): M24x1.5 · Thermowell body diameter: 18 mm (0.71 in), 24 mm (0.94 in), or 26 mm (1.02 in) · Tip diameter: 9 mm (0.35 in) or 12.5 mm (0.49 in)
The Endress + Hauser Omnigrad M TW15 is a heavy-duty, general-purpose thermowell designed for industrial processes with severe thermal and mechanical stresses.
iTherm Moduline TM412
temperature measurement › Thermowells
Measuring range: –200 to +600 °C (–328 to +1 112 °F) · Pressure range: up to 40 bar (580 psi) · Pt100 wire wound (extended measuring range): –200 to +600 °C (–328 to +1 112 °F)
The Endress + Hauser iTherm Moduline TM412 is a modular resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences...
iTherm TT511
temperature measurement › Thermowells
Process Temperature Range: Refer to the 'Material' section for maximum operating temperatures · Material Certification: Material certificate 3.1 (EN 10204) is optional · Permitted Flow Velocity: Diminishes with increasing immersion length exposed to the flow. It is also dependent on thermowell shape, medium type, process temperature, and pressure
The Endress+Hauser iTherm TT511 is an industrial thermowell designed for demanding Oil & Gas and Petrochemical applications, featuring a flexible Vanstone design.
TA414
temperature measurement › Thermowells
Process connection: Threaded, G 1/2" M · Standard material: AISI316Ti / W.1.4571
The Endress + Hauser TA414 is a pipe thermowell designed for processes without strong flow.
TU51, TU52, TU53, TU54
temperature measurement › Thermowells
Root/Tip Diameter: ± 0.01” · Insertion Length (A Dim.): ± 1/16”
The TU51, TU52, TU53, and TU54 are heavy-duty thermowells manufactured from drilled barstock for RTD and thermocouple assemblies in process industries.
TWF11, TWF16
temperature measurement › Thermowells
Kanthal Super (MoSi₂ with glass phase): Max. 1700 °C (3092 °F). Not affected by thermal shock, very low porosity. Not for environments with chlorine and fluorine compounds or mechanical shock
The Endress + Hauser TWF11 and TWF16 are metal or ceramic thermowells designed for high-temperature applications.
RTD TR13, TC13
temperature measurement › Modular thermometers
Pressure range: up to 100 bar (1,450 psi) · Flange connections: Max. process pressure depends on flange pressure rating (e.g., 20, 40, 50, 100 bar for EN1092-1/ISO 7005-1) · Degree of protection: up to IP 68
The Endress + Hauser TR13 is a resistance thermometer and the TC13 is a thermocouple, suitable for universal applications up to 1,100 °C and 100 bar.
RTD TR15, TC15
temperature measurement › Modular thermometers
Thermocouple Accuracy: Refer to IEC 60584 and ASTM E230/ANSI MC96.1 for standard and special tolerances · RTD Accuracy: Refer to IEC 60751 for Class A, AA, and B tolerances · Output Signals: 4 to 20 mA, HART®, PROFIBUS® PA, FOUNDATION Fieldbus™, PROFINET®
The TR15 and TC15 are universal temperature sensors suitable for steam and gas applications, with static pressure ratings up to 400 bar and IP68 protection.
RTD TR66, TC66
temperature measurement › Modular thermometers
Measuring Range (RTD): –200 to 600 °C (–328 to 1,112 °F) · Measuring Range (TC): –40 to 1,100 °C (–40 to 2,012 °F) · Static Pressure Range: Up to 100 bar (1,450 psi)
The Endress + Hauser RTD TR66 and TC66 are modular, explosion-protected thermometers with barstock thermowells, designed for heavy-duty oil and gas applications.
RTD TR88, TC88
temperature measurement › Modular thermometers
Threaded connection: Available in M, G, and NPT threads (e.g., M14x1.5, G 1/2", NPT 1/2") · Terminal head with mounted head transmitter: –40 to 85 °C (–40 to 185 °F) · Terminal head with mounted head transmitter and display: –20 to 70 °C (–4 to 158 °F)
The Endress+Hauser RTD TR88 and TC88 are modular thermometers designed for installation in existing thermowells, offering protection up to IP68.
Omnigrad-M-TR11
temperature measurement › Modular thermometers
Measuring range: -200 to 600 °C (-328 to 1112 °F) · Degree of protection: up to IP 68 · Insert with head transmitter: -40 to 85 °C (-40 to 185 °F)
This is a modular RTD assembly with a threaded process connection, suitable for a universal range of applications from -200 to 600 °C and up to 75 bar pressure.
Omnigrad-S TR15, TC15
temperature measurement › Modular thermometers
Lower connection: M14x1.5 (for 18 mm thermowells) or M18x1.5 (for 24 mm thermowells) · Process Connection: Weld-in or flanged · Thermowell Diameter: 18 mm or 24 mm
The Omnigrad-S TR15 and TC15 are thermocouple thermometers designed for heavy industrial steam and gas applications, featuring a modular DIN standard construction.
Omnigrad-S TR65, TC65
temperature measurement › Modular thermometers
Static Pressure Range: Up to 75 bar (depending on process connection) · Degree of Protection: Up to IP68 · With mounted head transmitter: –40 to 85 °C (–40 to 185 °F)
The Endress + Hauser Omnigrad-S TR65 and TC65 are modular thermometers designed for use in fine chemicals, petrochemicals, power stations, and environmental engineering.
iTherm Moduline TT131
temperature measurement › Modular thermometers
Pressure Range: Up to 100 bar (1,450 psi) · Process Temperature Range: -200 to +1,100 °C (–328 to +2,012 °F), depending on thermowell type and material · Thermowell Diameter Options: 9 mm x 1.25 mm, 11 mm x 2 mm, 12 mm x 2.5 mm, 14 mm x 2 mm, 16 mm x 3.5 mm, ¼" SCH80 (13.7 mm x 3 mm), ½" SCH80 (21.3 mm x 3.7 mm), ½" SCH40 (21.3 mm x 2.7 mm)
The iTherm TT131 is a welded thermowell designed to protect temperature sensors in demanding industrial applications across chemical, oil & gas, and power sectors.
iTherm Moduline TT151
temperature measurement › Modular thermometers
Selection cues: measuring range · accuracy · output signal and process connection
The Endress + Hauser iTherm Moduline TT151 is a temperature transmitter designed for industrial applications.
iTherm Moduline TT152
temperature measurement › Modular thermometers
Pressure range: up to 500 bar (7,252 psi) · Available process connections: flanged, threaded, weld-in, socket weld · Root diameter: 5/8" to 1½"
The Endress + Hauser iTherm Moduline TT152 is a barstock thermowell designed to protect thermometers from mechanical and chemical stress in pipes, vessels, or tanks.
iTemp TMT31
temperature measurement › Temperature transmitters
Measured Error (±) (in entire measuring range): 0.15 K or 0.07 % of span ¹) · Measured Error (±) (in limited range –50 to +250 °C): 0.1 K or 0.07 % of span ¹) · Output Signal: 4 to 20 mA, 20 to 4 mA (inversely configurable)
The Endress + Hauser iTEMP TMT31 is a Form B head-mounted temperature transmitter designed for high safety and availability with diagnostic functions.
iTemp TMT36
temperature measurement › Temperature transmitters
Connection type: 2-wire, 3-wire, or 4-wire · Signal: C/Q (IO-Link or switch output) · Switching capacity: ≤ 150 mA
The Endress + Hauser iTEMP TMT36 is a temperature transmitter designed for reliability and high precision using RTD sensors.
iTemp TMT71
temperature measurement › Temperature transmitters
Ambient temperature range: –40 to +85 °C (–40 to +185 °F). For hazardous areas, see Ex documentation · Output signal: 4 to 20 mA, 20 to 4 mA (invertible) · Connection type: 2-wire, 3-wire, or 4-wire
The iTEMP TMT71 is a universal temperature transmitter that converts various input signals into a scalable 4 to 20 mA output.
iTemp TMT72
temperature measurement › Temperature transmitters
Ambient temperature range: –40 to +85 °C (–40 to +185 °F) (non-hazardous areas) · Output signal: Analog 4 to 20 mA (20 to 4 mA, invertible) · Signal encoding: FSK ±0.5 mA via current signal
The Endress+Hauser iTEMP TMT72 is a universal temperature transmitter with HART® communication, converting various input signals into a scalable 4-20 mA analog output.
iTemp TMT80
temperature measurement › Temperature transmitters
Ambient temperature range: –40 to +85 °C (–40 to +185 °F) · TC reference junction accuracy: ± 1 K · Fault signal (sensor break/short circuit): Adjustable as per NAMUR NE43
The Endress+Hauser iTEMP TMT80 is a programmable temperature head transmitter designed for converting resistance thermometer and thermocouple signals into a scalable 4 to...
iTemp TMT82
temperature measurement › Temperature transmitters
Auxiliary power supply (head transmitter): 11 to 42 V DC · Auxiliary power supply (DIN rail device): 12 to 42 V DC · Auxiliary power supply (Ex ia): 11/12 to 30 V DC
The Endress + Hauser iTEMP TMT82 is a dual-channel, SIL-compliant temperature transmitter designed for hazardous areas.
iTemp TMT84
temperature measurement › Temperature transmitters
Ambient Temperature Range: –40 to +85 °C (for hazardous areas, refer to Ex documentation) · Output Data (via AI blocks): Temperature (PV), temperature sensor 1 & 2, terminal temperature · Ambient Temperature and Supply Voltage: Influence values are specified per 1 °C change in ambient temperature and per 1 V change in supply voltage for various sensor types
The Endress+Hauser iTEMP TMT84 is a dual-input temperature transmitter with PROFIBUS PA output, designed for critical processes and hazardous areas.
iTemp TMT85
temperature measurement › Temperature transmitters
Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F) (for hazardous areas, see Ex documentation) · Output Signal: FOUNDATION Fieldbus™ H1, IEC 61158-2 · Connection Combinations: Multiple combinations are possible between RTD/resistance transmitter (2-, 3-, or 4-wire) and Thermocouple/voltage transmitter inputs
The iTEMP TMT85 is a dual-input temperature transmitter featuring FOUNDATION Fieldbus™ H1 protocol and universal inputs for RTDs, thermocouples, resistance, and voltage.
iTemp TMT86
temperature measurement › Temperature transmitters
Output signal: PROFINET® according to IEEE 802.3cg 10BASE-T1L, 2-wire 10 Mbps · Connection types for RTD: 2-wire, 3-wire, or 4-wire · Supported connections: 2 x AR (IO Controller AR), 2 x AR (device access, acyclic communication)
The Endress + Hauser iTEMP TMT86 is a dual-input temperature transmitter supporting PROFINET with Ethernet-APL for system integration.
iTemp TMT127
temperature measurement › Temperature transmitters
Temperature range: -200 to 850 °C (-328 to 1562 °F) · Undershooting measuring range: linear decrease to 3.8 mA · Exceeding measuring range: linear increase to 20.5 mA
The iTEMP TMT127 is a 2-wire Pt100 temperature transmitter for industrial use that features a 4 to 20 mA analog output.
iTemp TMT128
temperature measurement › Temperature transmitters
High accuracy: 0.08 % of span · Accuracy of cold junction: ±1 K · Output: Analog, scalable 4 to 20 mA output signal
The Endress + Hauser iTemp TMT128 is a DIN rail mounted temperature transmitter for thermocouples, converting input signals into a scalable 4 to 20 mA output.
iTemp TMT142B
temperature measurement › Temperature transmitters
Range: 25 m (82 ft) (with display window), 10 m (33 ft) (without display window) under reference conditions · Signal encoding: FSK ±0.5 mA via current signal · Connection types: 2-wire, 3-wire, or 4-wire
The Endress+Hauser iTEMP TMT142B is a temperature field transmitter with HART and Bluetooth capabilities, converting various input signals into a scalable 4 to 20 mA...
iTemp TMT162
temperature measurement › Temperature transmitters
Connection: 2-wire, 3-wire, or 4-wire · Supply voltage: Ub = 9 to 32 V DC, polarity-independent · Maximum voltage: Ub = 35 V DC
The Endress + Hauser iTemp TMT162 is a temperature field transmitter with two sensor inputs and an illuminated display.
iTemp TMT182B
temperature measurement › Temperature transmitters
Signal Encoding: FSK ±0.5 mA via current signal · Time for Connection Setup: 9 s · Analog Output: 4 to 20 mA, 20 to 4 mA (invertible)
The Endress + Hauser iTEMP TMT182B is a universal temperature transmitter with HART® communication, converting various input signals into a scalable 4-20 mA analog output.
iTemp TMT188
temperature measurement › Temperature transmitters
Measurement range undercut: Linear drop to 3.8 mA · Exceeding measurement range: Linear rise to 20.5 mA · Cold junction accuracy: ± 1 K
This Endress + Hauser iTEMP TC TMT 188 is a temperature head transmitter designed for thermocouples that converts input signals to a 4 to 20 mA analog output.
TH51,TH52, TH56
temperature measurement › Thermocouples
Temperature range: –40 to +80 °C (–40 to +176 °F) · Connection: M12 on PROFIBUS®-PA or 7/8-16 UNC on FOUNDATION Fieldbus™ · Terminal head (with transmitter): –40 to 85 °C (–40 to 185 °F)
The Endress+Hauser TH51, TH52, and TH56 are general-purpose MgO insulated thermocouples designed for diverse process and laboratory temperature measurement applications.
TH53, TH54, TH55
temperature measurement › Thermocouples
Temperature range: –40 to +80 °C (–40 to +176 °F) · Electrical connection: Flying leads, standard 139.7 mm (5.5 in) · HART® head transmitters: 2-wire devices with one or two measuring inputs and one analog output, supporting resistance and voltage signals. Optional Bluetooth® interface available
The Endress+Hauser TH53, TH54, and TH55 are magnesium oxide insulated thermocouple assemblies for installation in barstock thermowells across various process industries.
TSC310
temperature measurement › Thermocouples
Maximum static process pressure: ≤ 40 bar (580 psi). Information on specific process connections is provided in the "Process connection" section · Maximum process pressure: 40 bar at 20 °C (580 psi at 68 °F) · Clamping ring material: SS316. Can only be used once
The Endress + Hauser TSC310 is a thermocouple thermometer for temperature measurement in gaseous or liquid media.
Omnigrad S TAF11
temperature measurement › High temperature thermometers
TAF11 Process Temperature: Up to +1600 °C (+2912 °F) · TAF12 Process Temperature: Up to +1700 °C (+3092 °F) · TAF16 Process Temperature: Up to +1700 °C (+3092 °F)
The Endress + Hauser Omnigrad S TAF11 is a high temperature assembly designed for steel treatment and concrete furnaces.
iTherm-Moduline-TM402
temperature measurement › Hygienic thermometers
Measuring range: –50 to +200 °C (–58 to +392 °F) · Pressure range: up to 40 bar (580 psi) · Process temperature range: –50 to +200 °C (–58 to +392 °F)
This resistance thermometer is designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries, with a measuring range of -50 to +200...
iTherm-Moduline-TU401
temperature measurement › Hygienic thermometers
Measuring range: –50 to +200 °C (–58 to +392 °F) · Pressure range: up to 50 bar (725 psi) · Protection class: up to IP69K
The iTHERM ModuLine TM401 is a resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
RTD MLTTS00
temperature measurement › Multipoint thermometers
Temperature range (without cable gland): –50 to +150 °C (–58 to +302 °F) · With mounted head transmitter: –40 to 85 °C (–40 to 185 °F) · With mounted head transmitter and display: –20 to 70 °C (–4 to 158 °F)
This modular thermometer is designed for use in the Oil & Gas industry, offering both Wire Wound and Thin Film RTD sensor options.
RTD MLTTS01
temperature measurement › Multipoint thermometers
Pressure Range: Up to 63 bar (914 psi) depending on process connection · Process Connections: Flange connections according to EN 1092-1 (e.g., DN25 PN40, DN25 PN63) · Power Supply (for transmitter): 24V DC / 30 mA (example using RN221N). Universal power supply 20 to 250 V DC/AC, 50/60 Hz
This modular thermometer is designed for universal temperature measurement, with specific applications in the Oil & Gas industry.
Easytemp TMR31
temperature measurement › Compact thermometers
Pressure Range: Up to 100 bar (1,450 psi) · Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F) · Process Pressure Range: See the official PDF for exact tabulated values
The Endress+Hauser Easytemp TMR31 is a compact RTD thermometer for industrial and hygienic applications, utilizing a Pt100 sensor.
Thermophant TTR31
temperature measurement › Temperature switches
Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F) · Process Temperature Range: –50 to +150 °C (–58 to +302 °F), or –50 to +200 °C (–58 to +392 °F) with extension neck. Restrictions apply based on ambient temperature and process connection · Process connection: AISI 316L
The Thermophant T TTR31 is a temperature switch with threaded connections or compression fitting, designed for monitoring, displaying, and controlling process...
iTherm Surfaceline TM611
temperature measurement › Surface thermometers
HART® head transmitters: 2-wire devices with one or two measuring inputs and one analog output. Support wireless configuration via optional Bluetooth® and E+H SmartBlue app · Head transmitter with PROFINET® and Ethernet-APL™: 2-wire device with two measurement inputs, supporting PROFINET® protocol · Supply voltage: Max. 9 to 42 VDC, depending on the iTEMP temperature transmitter used
The Endress+Hauser iTherm Surfaceline TM611 is a non-invasive surface thermometer designed for demanding industrial applications.
Product range and selection
This section answers two questions: which main product families Endress+Hauser offers, and which parameters to compare before choosing a specific model.
The main families shown on this page are Flow measurement, Level measurement, Liquid analysis, and Pressure measurement. Start with the treatment objective, equipment format, and operating duty, then use the model index below to compare exact specifications.
After choosing a product family, compare measurement parameter, sample condition, signal integration, and maintenance frequency. Replacement projects should also verify installation or loading conditions, interfaces, and compatibility with the existing system; new projects should consider operating practice, maintenance, and spare-parts or consumables availability.
5 product families on this page.
Flow measurement
77 models in this family, organized across 6 subfamilies. Representative models: Proline Cubemass C 300, Proline Cubemass C 500, Proline Promass A 100.
Level measurement
89 models in this family, organized across 9 subfamilies. Representative models: Liquiphant Failsafe FTL80, Liquiphant FTL41, Liquiphant FTL43.
Liquid analysis
148 models in this family, organized across 13 subfamilies. Representative models: Ceraliquid CPS41, Ceramax CPS341D, CPS31D.
Pressure measurement
23 models in this family, organized across 2 subfamilies. Representative models: Cerabar PMC11, Cerabar M PMC51, Cerabar M PMC51B.
temperature measurement
71 models in this family, organized across 11 subfamilies. Representative models: RTD T13, T14, T15, RTD T53, T54, T55, RTD TH11, TH12.
Brand Products & Technical Documents
View product applications, datasheets and family manuals.
77 product profiles
Product profile
The Proline Cubemass C 300 is a compact Coriolis flowmeter designed for measuring small flow rates in skids, test rigs, and robotics, suitable for high-pressure and...
Product profile
The Proline Cubemass C 500 is a compact Coriolis flowmeter designed for measuring the smallest flow rates in skids, test rigs, and industrial robotics.
Product profile
The Endress + Hauser Proline Promass A 100 is a compact Coriolis flowmeter designed for precise measurement of small liquid and gas quantities.
Product profile
The Proline Promass A 200 is a loop-powered Coriolis flowmeter designed for accurate measurement of lowest flow rates in demanding applications.
Product profile
The Endress+Hauser Proline Promass A 300 is a compact Coriolis flowmeter designed for continuous process control of liquids and gases.
Product profile
The Endress + Hauser Proline Promass A 500 is a compact Coriolis flowmeter designed for demanding applications, offering accurate measurement of liquids and gases at low...
Product profile
The Proline Promass E 100 is a mid-range Coriolis flowmeter designed for accurate liquid and gas measurement in standard applications with an ultra-compact transmitter.
Product profile
The Endress + Hauser Proline Promass E 200 is a Coriolis flowmeter designed for accurate liquid and gas measurement in standard chemical industry applications, including...
Product profile
The Endress + Hauser Proline Promass E 300 is a mid-range Coriolis flowmeter designed for accurate measurement of liquids and gases in standard applications.
Product profile
Proline Promass E 500 is a variable-speed drive product, best compared by power range, control mode, enclosure rating, and pump or fan duty.
Product profile
The Proline Promass F 100 is an ultra-compact Coriolis flowmeter designed for precise measurement of mass flow, density, and temperature.
Product profile
The Proline Promass F 200 is a robust Coriolis flowmeter offering high measurement performance for liquids and gases across various applications.
Product profile
The Proline Promass F 300 is a Coriolis flowmeter offering premium accuracy and robustness for mass and volume flow measurement.
Product profile
The Proline Promass F 500 is a high-accuracy Coriolis flowmeter for demanding liquid and gas applications, featuring integrated Heartbeat Technology for reliability.
Product profile
The Endress + Hauser Proline Promass G 100 is a compact Coriolis flowmeter designed for accurate measurement of liquids and gases in high-pressure applications.
Product profile
The Proline Promass H 100 is a chemically resistant Coriolis flowmeter with an ultra-compact transmitter, designed for aggressive fluids in space-constrained applications.
Product profile
The Proline Promass H 300 is a highly accurate, chemically resistant Coriolis flowmeter designed for aggressive fluids.
Product profile
The Proline Promass H 500 is a remote version Coriolis flowmeter designed for aggressive fluids requiring highest corrosion resistance and accuracy.
Product profile
The Endress + Hauser Proline Promass I 100 is an ultra-compact Coriolis flowmeter designed for measuring liquids and gases with minimal pressure loss.
Product profile
The Endress + Hauser Proline Promass I 300 is a straight single-tube Coriolis flowmeter designed for accurate liquid and gas measurement with low pressure loss.
Product profile
The Endress + Hauser Proline Promass I 500 is a remote transmitter Coriolis flowmeter designed for measuring liquids and gases with low pressure loss and gentle fluid...
Product profile
The Endress + Hauser Proline Promass K 10 is a compact Coriolis mass flowmeter designed for cost-efficient measurement of liquids and gases.
Product profile
The Proline Promass O 100 is a robust, ultra-compact Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications, suitable for offshore...
Product profile
The Endress + Hauser Proline Promass O 300 is a robust Coriolis flowmeter designed for premium accuracy in liquids and gases at the highest process pressures, suitable...
Product profile
The Proline Promass O 500 is a robust, remote-version Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications, including offshore...
Product profile
The Endress + Hauser Proline Promass P 100 is a Coriolis flowmeter designed for sterile conditions in the life sciences industry.
Product profile
The Endress + Hauser Proline Promass P 300 is a specialist Coriolis mass flow meter designed for sterile applications in the life sciences industry.
Product profile
The Proline Promass P 500 is a specialist Coriolis flowmeter designed for sterile processes in the life sciences industry.
Product profile
The Proline Promass Q 300 is a Coriolis flowmeter designed for challenging applications, including custody transfer and liquids with entrained gas.
Product profile
The Endress+Hauser Proline Promass Q 500 is a Coriolis flowmeter optimized for challenging custody transfer applications, including liquids with entrained gas using...
Product profile
The Proline Promass S 100 is a hygienic Coriolis flowmeter designed for food and beverage applications with a self-drainable single-tube system.
Product profile
The Endress + Hauser Proline Promass S 300 is a hygienic Coriolis flowmeter designed for demanding applications in the food and beverage industry.
Product profile
The Proline Promass S 500 is a remote Coriolis flowmeter designed for hygienic applications in the food and beverage industry.
Product profile
Product Name:Proline Promass X 300、Product Type:Coriolis flowmeter、Description:Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.
Product profile
This Proline Promass X 500 is a remote-mount Coriolis flowmeter designed for the highest flow rates and demanding on/offshore oil and gas applications.
Product profile
The FLOWRUN is a modular gas metering system designed for industry-standard applications with low measurement uncertainty.
Product profile
The Endress + Hauser FLOWSKID is a complete gas flow metering system designed for custody transfer applications.
Product profile
The Endress + Hauser Dosimag-5BH is an electromagnetic flowmeter designed for precise dosing and filling of conductive liquids in hygienic applications.
Product profile
The Endress+Hauser Dosimag-D5AB is an electromagnetic flowmeter designed for hygienic dosing and filling of conductive liquids in the Food & Beverage and Life Sciences...
Product profile
The Endress+Hauser Dosimass-8BE is a compact Coriolis flow meter designed for filling and bottling applications, measuring mass flow, density, and temperature.
Product profile
The Endress + Hauser Magphant DTI200 is a compact, cost-effective electromagnetic flowmeter and limit switch designed for water applications in utilities.
Product profile
The Picomag-DMA is an electromagnetic flowmeter designed for conductive liquids in various industries, measuring volume flow, temperature, and conductivity.
Product profile
The Proline Promag D 10 is a cost-effective electromagnetic flowmeter designed for basic water applications in installations with limited space and plastic piping.
Product profile
The Endress + Hauser Proline Promag E 100 is an economical magnetic flowmeter designed for basic applications in the chemical and process industry.
Product profile
The Proline Promag H 10 is an electromagnetic flowmeter designed for basic hygienic applications in the food and beverage and life sciences industries.
Product profile
This is an electromagnetic flowmeter designed for hygienic applications in the food, beverage, and life sciences industries.
Product profile
This is an electromagnetic flowmeter designed for the measurement of smallest flow rates with genuine loop-powered technology.
Product profile
The Proline Promag H 500 is an electromagnetic flowmeter designed for demanding hygienic applications in the food and beverage and life sciences industries.
Product profile
The Endress+Hauser Proline Promag P 10 is an electromagnetic flowmeter designed for basic process applications with corrosive liquids and high medium temperatures.
Product profile
The Endress + Hauser Proline Promag P 100 is an electromagnetic flowmeter designed for corrosive liquids and high medium temperatures.
Product profile
The Proline Promag P 200 is an electromagnetic flowmeter designed for corrosive liquids and high temperatures, suitable for hazardous areas.
Product profile
The Proline Promag P 300 is a high-temperature electromagnetic flowmeter designed for corrosive liquids in demanding chemical and process applications.
Product profile
The Proline Promag P 500 is a remote-version electromagnetic flowmeter designed for high-temperature and corrosive chemical process applications.
Product profile
This is an electromagnetic flowmeter designed for basic water and wastewater applications, featuring international drinking water approvals.
Product profile
The Proline Promag W 300 is an electromagnetic flowmeter designed for demanding water and wastewater applications.
Product profile
This versatile standard flowmeter is designed for the water and wastewater industry, offering reliable measurement with no pressure loss and flexible engineering for...
Product profile
The Proline Promag W 500 is an electromagnetic flowmeter specialized for demanding water and wastewater applications, available in a remote version with up to four I/Os.
Product profile
This is a battery-powered electromagnetic flowmeter designed for water industry applications, featuring EN ISO 12944 corrosion protection and an intelligent...
Product profile
The Endress+Hauser Promag 55S is an electromagnetic flowmeter designed for abrasive, corrosive, and inhomogeneous fluids with integrated solids content diagnostics.
Product profile
The Endress + Hauser Flowphant T DTT31 is an intelligent insertion-style thermal flow switch for liquid applications, featuring practically no pressure loss.
Product profile
The Proline Prosonic Flow E 100 is an economical ultrasonic flowmeter with integrated temperature measurement for demineralized water applications.
Product profile
The Endress + Hauser Proline Prosonic Flow I 400 is an insertion ultrasonic flowmeter designed for water and wastewater applications in large pipelines.
Product profile
The Endress + Hauser Proline Prosonic Flow W 400 is an ultrasonic clamp-on flowmeter designed for reliable and maintenance-free measurement of conductive and...
Product profile
The Endress + Hauser Promass U 500 is a Coriolis flowmeter designed for single-use biopharmaceutical applications, particularly in monoclonal antibody processes.
Product profile
This Prosonic Flow Clamp On 9P5B is an ultrasonic clamp-on flowmeter for various fluids in process industries, featuring a flexible mounting system that minimizes inlet...
Product profile
The Endress + Hauser Prosonic Flow 91W is a clamp-on ultrasonic flow meter for process water, salt water, and wastewater.
Product profile
The Prosonic Flow Clamp On 93TA1 is a portable ultrasonic flowmeter designed for temporary monitoring and test measurements of liquid applications from outside the pipe.
Product profile
The Endress + Hauser Prosonic Flow E Heat 9EHB is an industrial ultrasonic heat flow sensor designed for enhanced energy management and custody transfer.
Product profile
The Prosonic Flow Inline 92F is an ultrasonic flowmeter designed for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industries.
Product profile
The Teqwave F is an inline ultrasonic concentration meter designed for real-time liquid analysis in pipes, offering flexible application definition and simultaneous...
Product profile
Teqwave H is an online instrument or sensor product for water systems, best compared by measured parameter, range, mounting style, and signal interface.
Product profile
The Endress + Hauser Teqwave I is an insertion-type ultrasonic concentration meter designed for real-time liquid analysis in vessels and larger pipes.
Product profile
The Endress+ Hauser Teqwave T is a portable ultrasonic concentration meter designed for in situ liquid analysis.
Product profile
The Endress + Hauser Proline Prowirl D 200 is a cost-effective vortex flowmeter available in compact or remote versions, suitable for basic applications and steam flow...
Product profile
The Proline Prowirl F 200 is a multivariable vortex flowmeter designed for reliable steam, gas, and liquid measurement, offering integrated temperature and pressure...
Product profile
The Endress + Hauser Proline Prowirl O 200 is a vortex flowmeter designed for demanding gas and steam applications with high process pressure.
Product profile
The Endress + Hauser Proline Prowirl R 200 is a vortex flowmeter designed for low flows and energy management, featuring integrated pipe reduction.
89 product profiles
Product profile
The Liquicap FTZ61 is a transmitter designed for capacitive foam detection in single-use bioreactors, mounting externally to non-conducting containers.
Product profile
The Endress+Hauser Liquicap M FMI51 is a capacitive level sensor for continuous measurement of liquids in a wide temperature range from -80 to +200 °C.
Product profile
The Liquicap M FMI52 is a capacitive level probe for continuous liquid measurement, offering independence from dielectric constant for media with conductivity above 100...
Product profile
The Liquicap M FTI51 is a capacitance point level switch designed for detecting liquids, including viscous media, pastes, and foam.
Product profile
The Endress + Hauser Liquicap T FMI21 is a capacitive level sensor for continuous measurement in conductive liquids.
Product profile
The Endress + Hauser Minicap FTC260 is a capacitive point level switch designed for detecting bulk solids and liquids.
Product profile
The Endress + Hauser Nivector FTI26 is a capacitance-based point level switch designed for detecting minimum or maximum levels of powdered and fine-grained solids in...
Product profile
The Endress + Hauser Nivotester FTC325 is a point level switch with an intrinsically safe signal circuit suitable for liquid and bulk solid detection in hazardous areas.
Product profile
The Solicap M FTI55 is a capacitance point level switch designed for reliable detection in bulk solids.
Product profile
The Solicap S FTI77 is a capacitance point level switch designed for challenging bulk solid applications, including high temperatures and abrasive media.
Product profile
The Endress + Hauser 11362Z is a double rod probe designed for limit detection and two-point control in plastic or non-conducting vessels, suitable for corrosive liquids...
Product profile
The Liquipoint T FTW31 is a conductive point level switch designed for overfill protection, dry running protection, and pump control in conductive liquids with a minimum...
Product profile
This Endress + Hauser 11371 is a partially insulated rod probe for conductive level limit detection in liquid foodstuffs.
Product profile
This is a partially insulated rod probe for conductive level limit detection in process or storage tanks.
Product profile
The Endress + Hauser 11961Z is a partially insulated rod probe for conductive level limit detection in various liquids.
Product profile
The Silopilot FMM50 is an electromechanical level system for bulk solids and liquids, offering a measuring principle independent of physical properties.
Product profile
The Endress + Hauser Silopilot FMM20 is an electromechanical level system designed for light bulk solids and liquids in bunkers and silos, offering reliable measurement...
Product profile
The Soliswitch FTE20 is a rotary paddle point level switch designed for robust, reliable detection in bulk solids silos.
Product profile
The Levelflex FMP51 is a guided wave radar instrument for liquid level and interface measurement, offering rod, rope, or coax probe options.
Product profile
The Endress + Hauser Levelflex FMP55 is a guided-wave radar level transmitter for interface measurement in liquids.
Product profile
The Levelflex FMP56 is a guided-wave radar level measurement device designed for bulk solids.
Product profile
The Endress + Hauser Levelflex FMP50 is a guided-wave radar sensor for liquid level measurement.
Product profile
The Solimotion FTR16 is an ultra-compact flow indicator designed for monitoring bulk solids transport processes, capable of non-contact detection even through...
Product profile
The Solimotion FTR20 is a flow indicator designed for monitoring pneumatic and mechanical transport processes of bulk solids.
Product profile
The Endress + Hauser Soliwave FDR16 is an ultra-compact microwave barrier for non-contact point level detection of bulk solids, liquids, and piece goods.
Product profile
The Soliwave FDR56 is a compact, non-contact microwave barrier for limit detection in bulk solids and liquids.
Product profile
The Soliwave FDR57 is a microwave barrier used for non-contact level limit detection up to 100m and bulk flow detection up to 10m.
Product profile
The FQG60 is a radiometric level measurement 11 GBq. It features a lightweight, compact design with optimized screening and is fire-resistant up to 821 °C for 30 minutes.
Product profile
The It offers safe and easy radioactive.
Product profile
The FQG63 is a It features a lightweight spherical design with lead screening and a flexible installation length up to 30 meters, with an optional fire-resistant version...
Product profile
The Endress + Hauser It offers manual or pneumatic switch-on/switch-off operation and can accommodate up to 740 GBq of ¹³⁷Cs or 185 GBq of ⁶⁰Co radioactive.
Product profile
This Endress+Hauser triple rod probe is designed for two-point control and limit detection in plastic or conducting vessels, with the 11363 Z version suitable for...
Product profile
The Micropilot FMR10 is a free space radar sensor for level measurement in liquids within storage tanks and open basins.
Product profile
The Micropilot FMR10B is a free-space radar sensor for continuous, non-contact level measurement of liquids and bulk solids, and can also be used for flow measurement in...
Product profile
The Endress + Hauser Micropilot FMR20B is a free-space radar sensor for continuous, non-contact level measurement of liquids and bulk solids.
Product profile
This is a free-space radar level sensor for continuous, non-contact measurement of liquids and bulk solids, also capable of flow measurement in open channels.
Product profile
The Micropilot FMR43 is a free-space radar transmitter for continuous, non-contact level measurement in hygienic applications.
Product profile
The Micropilot FMR20 is a free space radar sensor designed for level measurement of bulk solids up to 10 meters.
Product profile
The Endress+Hauser Micropilot FMR50 is a non-contact radar level instrument for continuous measurement of liquids, pastes, and slurries.
Product profile
The Endress + Hauser Micropilot M FMR51 is a free space radar level sensor for continuous, non-contact measurement of liquids, pastes, and slurries.
Product profile
The Micropilot M FMR53 is a free-space radar level sensor designed for continuous, non-contact measurement of liquids, pastes, and sludges, featuring a rod antenna.
Product profile
The Micropilot M FMR56 is a free-space radar instrument for continuous, non-contact level measurement of bulk solids.
Product profile
The Micropilot FMR60 is a free space radar instrument for continuous, non-contact liquid, paste, and sludge level measurement.
Product profile
The Micropilot M FMR60B is a free-space radar transmitter for continuous, non-contact level measurement of liquids, pastes, and sludges.
Product profile
The Endress+Hauser Micropilot FMR62 is a free-space radar level measuring instrument for continuous, non-contact level measurement of liquids, pastes, and sludges.
Product profile
The Endress + Hauser Micropilot FMR62B is a free-space radar instrument for continuous, non-contact level measurement of liquids, pastes, and sludges.
Product profile
The Endress+Hauser Micropilot FMR63B is a free-space radar level instrument designed for hygienic applications with continuous, non-contact liquid measurement.
Product profile
The Micropilot FMR66B is a free-space radar level sensor designed for continuous, non-contact measurement of powdered to granular bulk solids.
Product profile
The Endress+Hauser Micropilot M FMR67 is a free space radar sensor for continuous, non-contact level measurement of bulk solids.
Product profile
The Endress + Hauser Micropilot M FMR67B is a non-contact free-space radar transmitter for continuous level measurement of bulk solids.
Product profile
The Micropilot S FMR532 is a non-contact radar level transmitter designed for continuous measurement in custody transfer and inventory control applications.
Product profile
The Micropilot S FMR540 is a continuous, non-contact radar level transmitter for custody transfer and inventory control, offering accuracy better than 1 mm.
Product profile
The Endress+Hauser Micropilot FWR30 is a battery-operated free-space radar level sensor designed for remote and mobile applications.
Product profile
The Gamma Modulator FHG65 is a radiometric system component designed to enhance measurement accuracy by suppressing background and extraneous radiation.
Product profile
The Gammapilot FMG50 is a compact transmitter for non-contact level, interface, density, and concentration measurement in vessels.
Product profile
The Endress + Hauser Gammapilot FTG20 is a non-contact radiometric point level measurement device for liquids, solids, and sludges, suitable for extreme conditions like...
Product profile
The Prosonic FMU30 is a compact, non-contact ultrasonic transmitter for continuous level measurement of fluids, pastes, and bulk materials, offering system integration...
Product profile
The Endress + Hauser Prosonic FMU41 is a compact, two-wire transmitter utilizing ultrasonic technology for non-contact level and flow measurement of liquids and bulk...
Product profile
The Prosonic FMU42 is a compact, two-wire transmitter utilizing ultrasonic technology for non-contact level and flow measurement in liquids and bulk solids.
Product profile
The Endress + Hauser Prosonic FMU44 is a compact, non-contact ultrasonic transmitter for level and flow measurement.
Product profile
The Prosonic S FDU90 is an ultrasonic sensor designed for non-contact level measurement of liquids and bulk solids, and for flow measurement in open channels.
Product profile
The Prosonic S FDU91 is an ultrasonic sensor for continuous, non-contact level measurement of liquids and solids, as well as flow measurement in open channels.
Product profile
The Endress+Hauser Prosonic S FDU91F is an ultrasonic sensor for continuous, non-contact level and flow measurement in various applications.
Product profile
The Prosonic S FDU92 is an ultrasonic sensor designed for continuous, non-contact level measurement of liquids and bulk solids, as well as flow measurement in open...
Product profile
The Prosonic S FDU93 is an ultrasonic sensor designed for continuous, non-contact level measurement of liquids and bulk solids, as well as flow measurement in open...
Product profile
The Prosonic S FDU95 is an ultrasonic sensor for continuous, non-contact level and flow measurement in liquids and bulk solids.
Product profile
The Prosonic S FMU90 is an ultrasonic transmitter for level and flow measurement in liquids or bulk solids, supporting one or two sensors.
Product profile
The Prosonic S FMU95 is an ultrasonic transmitter for continuous, non-contact level measurement of fluids, pastes, sludge, and bulk materials, supporting up to 10...
Product profile
The Liquiphant FailSafe FTL80 is a vibronic point level switch for minimum and maximum detection in liquids, suitable for highly corrosive media.
Product profile
This Endress + Hauser Liquiphant FTL41 is a vibronic point level switch for maximum or minimum detection in tanks, containers, and piping with all types of liquids.
Product profile
The Liquiphant FTL43 is a point level switch for all pumpable liquids, ideal for hazardous areas and offering hygienic design certifications.
Product profile
The Liquiphant FTL51B is a vibronic point level switch for liquids.
Product profile
The Liquiphant FTL62 is a point level switch designed for all liquids, offering reliable detection in tanks and piping, even in hazardous areas.
Product profile
The Liquiphant FTL63 is a vibronic point level switch for detecting minimum or maximum levels in pumpable liquids across various applications.
Product profile
The Endress+Hauser Liquiphant FTL64 is a vibronic point level switch for all liquids, designed for hazardous areas and high-temperature applications up to 280 °C.
Product profile
The Endress + Hauser Liquiphant M FTL50 is a vibronic point level switch designed for all types of liquids in tanks or pipes.
Product profile
The Endress+Hauser Liquiphant M FTL50H is a vibronic point level switch suitable for all liquid types in demanding applications.
Product profile
The Liquiphant M FTL51C is a vibronic point level switch for detecting maximum or minimum levels in all types of liquids.
Product profile
The Liquiphant FTL31 is a point level switch for liquids, designed for challenging applications where other sensors may fail.
Product profile
The Liquiphant T FTL33 is a vibronic point level switch for liquids, featuring robust stainless steel construction with EHEDG and 3-A certifications.
Product profile
The Endress + Hauser Liquipoint FTW23 is a capacitance point level switch suitable for water-based, alcohol-based, and oil-based liquids, or powdered products.
Product profile
The Liquipoint FTW33 is a point level switch designed for hygienic applications in the food and beverage industry, suitable for liquids and pastes with a dielectric...
Product profile
The Nivotester FTL325N is an isolating amplifier for level limit detection in hazardous areas and liquid detection in pipes.
Product profile
The Nivotester FailSafe FTL825 is a two-wire system point level switch designed for fail-safe liquid detection in safety systems up to SIL3.
Product profile
The Endress + Hauser Nivotester FTW325 is a conductive point level switch designed for overfill protection, dry run protection, and point level detection in hazardous...
Product profile
The Soliphant M FTM50 is a vibronic point level switch for fine-grained bulk solids, offering SIL2 functional safety and resistance to buildup.
Product profile
The Soliphant M FTM51 is a universal point level switch designed for fine-grained or dusty bulk solids, with options for potentially explosive atmospheres.
Product profile
The Soliphant M FTM52 is a universal point level switch for fine-grained bulk solids, utilizing a vibronic measuring principle.
Product profile
The Endress+Hauser Soliphant T FTM20 is a vibronic point level switch designed for bulk solids, featuring a compact design and maintenance-free operation.
148 product profiles
Product profile
The Liquiline System CA80AL is a wet-chemical analyzer for near-continuous determination of aluminum in liquid media using the Pyrocatechol violet method.
Product profile
The Liquiline System CA80AM is a wet-chemical analyzer for continuous ammonium determination in liquids using a colorimetric method.
Product profile
The Liquiline System CA80COD is a wet-chemical analyzer designed for determining chemical oxygen demand (COD) in wastewater treatment and industrial applications.
Product profile
The Liquiline System CA80CR is a wet-chemical analyzer for near-continuous chromate (Cr (VI)) determination in liquid media.
Product profile
The Liquiline System CA80FE is a wet-chemical analyzer for near-continuous determination of dissolved iron in liquid media, utilizing a colorimetric measuring principle.
Product profile
The Liquiline System CA80HA is a wet-chemical analyzer for near-continuous total hardness concentration determination using a colorimetric method.
Product profile
The Liquiline System CA80NO is a wet-chemical analyzer designed for continuous nitrite determination in liquid media using a colorimetric method.
Product profile
The Liquiline System CA80SI is a wet-chemical analyzer for continuous silica concentration measurement in ultrapure and boiler feedwater.
Product profile
The Liquiline System CA80TN is a wet-chemical analyzer for near-continuous total nitrogen determination in liquid media using UV photometry.
Product profile
The Endress + Hauser Liquiline System CA80TP is a wet-chemical analyzer for continuous total phosphorus determination in liquid media, featuring a colorimetric measuring...
Product profile
The Memosens CCS55E is a digital sensor using Memosens technology for determining free bromine in seawater, process water, and pool applications.
Product profile
This Memosens CFS51 is a sensor for fluorescence measurement of polycyclic aromatic hydrocarbons (PAHs) in water, compliant with marine standards MEPC.259(68) and MEPC.
Product profile
The CleanFit CPA450 is a retractable assembly designed for pH, redox, oxygen, and conductivity measurements in power stations and the chemical industry.
Product profile
The CleanFit CPA472D is a heavy-duty retractable process assembly for pH and ORP sensors in harsh industrial environments.
Product profile
The CleanFit CPA474 is a retractable plastic process assembly designed for pH and ORP electrodes, offering safe process isolation via a ball valve.
Product profile
The CleanFit CPA871 is a flexible retractable process assembly for standard 12 mm pH and redox sensors, suitable for demanding applications including hazardous areas.
Product profile
The Endress+Hauser Cleanfit CPA875 is a modular retractable process assembly for in-line measurement of parameters like pH, ORP, and oxygen in sterile, hygienic, and...
Product profile
This assembly is designed for use in: Drinking water and process water:Filter monitoring and backflushing, phase separation monitoring, raw water monitoring, and sludge...
Product profile
The CleanFit P CPA473 is a retractable stainless steel process assembly designed for pH and ORP electrodes across various industries.
Product profile
These are Endress+Hauser CPK pH and redox measuring cables and junction boxes designed for high-impedance electrode systems.
Product profile
This CYA680 flow assembly is designed for hygienic and sterile applications in the life sciences and chemical industries, accommodating 12 mm sensors in small pipe...
Product profile
The Endress+Hauser CYH 101 is a universal suspension assembly holder designed for open channels, basins, and tanks in wastewater treatment applications.
Product profile
This is an immersion assembly with a flange connection designed for demanding chemical, power generation, and metal processing applications.
Product profile
The DipFit CPA111 is an immersion and installation assembly for pH/ORP and temperature sensors in open and closed vessels.
Product profile
The Dipfit CPA140 is an immersion assembly with flange connection for demanding industrial applications, capable of housing three 12 mm sensors.
Product profile
The EcoFit CPA640 is a universal compact assembly for installing 120 mm sensors with Pg 13.5 threads into NPT process connections, suitable for water and process...
Product profile
The Flexdip CYA112 is an immersion assembly designed for water and wastewater applications in plant construction.
Product profile
The Endress + Hauser Flexdip CYH112 is a versatile holder for water and wastewater assemblies, designed for simple and cost-effective installation on floors, walls,...
Product profile
The FlowFit CPA240 is a versatile flow assembly designed for 12 mm sensors in demanding industrial applications, including chemical processing and power generation.
Product profile
The FlowFit CYA21 is a universal assembly for analytical systems in industrial utilities, suitable for power stations and water treatment applications.
Product profile
The FlowFit CYA27 is a modular bypass flow assembly for multiparameter water analysis, capable of measuring up to six parameters and offering flexible installation.
Product profile
The FlowFit W CUA250 is a process and flow assembly designed for turbidity measurement applications in wastewater and industrial water recycling.
Product profile
The Endress + Hauser Memosens CYK10 and CYK11 are measuring cables and installation accessories for Memosens sensors, offering contactless digital signal transmission and...
Product profile
The Unifit CPA842 is a hygienic process assembly designed for the safe installation of 12 mm sensors in food, beverage, and life sciences industries.
Product profile
The Endress + Hauser DipFit W CPA510 is a sensor assembly suitable for water and wastewater treatment applications, capable of holding combined pH, redox, or conductivity...
Product profile
The Endress + Hauser DipFit W CPA 530 is a suspended assembly with a bayonet lock for water and wastewater treatment in conduits, ducts, or tall tanks where clearance is...
Product profile
These weld-in adapters are designed to connect level, pressure, or temperature measuring instruments to vessels or pipes.
Product profile
The Liquiline System CAT17 is an automatic sample preparation system designed for supplying filtered samples from pressure pipes to process measuring devices.
Product profile
The Liquiline System CAT810 is an automatic sample preparation system designed for filtered sample delivery to process measuring devices from pressure pipes.
Product profile
The Liquiline System CAT820 is an automatic sample conditioning system designed for supplying filtered samples to process measuring devices in wastewater treatment and...
Product profile
The Liquiline System CAT860 is an automatic sample conditioning system designed for preparing aqueous samples from wastewater treatment plants for process analyzers.
Product profile
The Liquiport CSP44 is an automatic sampler for liquid media with an integrated multi-parameter controller, featuring two measuring channels and optional digital Memosens...
Product profile
The Liquistation CSF28 is an automatic stationary sampler designed for municipal and industrial wastewater treatment plants and authorities.
Product profile
The Liquistation CSF34 is an automatic stationary sampler for liquid media, featuring integrated controller with up to four Memosens channels for applications in...
Product profile
The Liquistation CSF39 is an automatic stationary sampler for liquid media with self-draining and integrated controller capabilities.
Product profile
The Liquistation CSF48 is a stationary liquid sampler for wastewater treatment and industrial process monitoring, capable of automated removal, distribution, and...
Product profile
The Endress+Hauser CCS51 is an amperometric sensor for measuring free chlorine in drinking water, food industry, utilities, and pool water.
Product profile
The Endress + Hauser CCS120 is an amperometric sensor designed for measuring total chlorine in drinking water, pool water, service water, and wastewater treatment...
Product profile
This transmitter is designed for measuring free chlorine, chlorine dioxide, and total chlorine in various water treatment applications.
Product profile
The Memosens CCS51E is a digital sensor utilizing Memosens technology for the amperometric measurement of free chlorine in drinking water, utilities, and process...
Product profile
This Memosens CCS53E is a digital sensor utilizing Memosens technology for total chlorine measurement in various water applications.
Product profile
The Condumax CLS12 is a two-electrode conductivity sensor designed for high-temperature and high-pressure applications in power and energy industries, suitable for...
Product profile
The Endress + Hauser Condumax CLS13 is a conductivity sensor designed for high-temperature and high-pressure applications in power plants.
Product profile
The Condumax CLS15 is a conductivity sensor designed for pure and ultrapure water applications like ion exchange and reverse osmosis.
Product profile
The Condumax CLS16B is an analog conductivity sensor designed for applications such as ion exchanger monitoring and reverse osmosis.
Product profile
The Condumax CLS19 is a conductivity sensor designed for measuring conductivity in pure and ultrapure water applications.
Product profile
This is an analog or digital conductivity sensor with Memosens technology, suitable for media with average to high conductivity in applications like wastewater treatment...
Product profile
The DipFit CLA111 is an immersion and installation assembly for conductivity sensors in open and closed vessels.
Product profile
The Liquiline To Go CYM292-Ex-CYM291 is a portable multiparameter handheld device for pH, ORP, conductivity, and oxygen measurements.
Product profile
The Liquisys M CLM223/253 is a transmitter for conductive and inductive sensors used in various water treatment applications including ultrapure water.
Product profile
This Endress + Hauser Memosens CLL47E is a digital contacting conductivity sensor for laboratory and field measurements, designed for sticky and viscous samples.
Product profile
This digital conductivity sensor with Memosens 2.0 technology is designed for measurements in pure and ultrapure water applications like ion exchangers and reverse...
Product profile
The Memosens CLS16E is a digital conductivity sensor designed for precise measurements in pure and ultrapure water applications.
Product profile
The Endress + Hauser Memosens CLS21E is a digital conductivity sensor designed for measurements in media with medium or high conductivity, suitable for applications in...
Product profile
The Memosens CLS82E is a hygienic conductivity sensor designed for a wide range of applications including fermentations, CIP monitoring, and ballast water cleaning.
Product profile
The Smartec CLD134 is a hygienic inductive conductivity and concentration measuring system for applications in the food, beverage, pharmaceutical, and biotechnology...
Product profile
The Smartec S CLD132 is a measuring system with an inductive sensor for conductivity and concentration measurement, widely used in the food and beverage industries for...
Product profile
The Endress + Hauser CA76NA is a potentiometric analyzer designed for monitoring sodium ion concentration in various water applications, including power stations and...
Product profile
The Chemoclean CYR10B is a cleaning injector with a dosing function for universal use in automatic sensor cleaning systems.
Product profile
The CleanFit Control CYC25 is an automatic cleaning unit for sensors installed in retractable assemblies, designed for various industrial sectors including water and...
Product profile
This Endress + Hauser CPY3 is a laboratory chemical buffer solution for pH measurement.
Product profile
The Endress + Hauser CYM17 is a Memosens analog converter designed for digital pH and oxygen sensors in laboratory fermenters.
Product profile
The Endress + Hauser CCS58E is a digital ozone sensor utilizing amperometric measurement with Memosens technology for wastewater, drinking water, and process water...
Product profile
The ISEmax CAS40D is an ion-selective sensor designed for continuous online measurement of nutrient parameters like ammonium and nitrate in municipal wastewater treatment...
Product profile
The Ceragel CPS72 is an ORP electrode designed for hygienic, sterile, and process applications with poison-resistant reference technology.
Product profile
The Memosens CPF82E is an ORP sensor utilizing Memosens 2.0 technology for applications in mining and industrial water treatment.
Product profile
The Memosens CPS12E is an ORP sensor for standard applications in process technology and environmental engineering, featuring Memosens 2.0 technology for safe, digital...
Product profile
The Memosens CPS42E is a digital ORP sensor utilizing Memosens 2.0 technology for process applications in industries such as chemical and power generation.
Product profile
The Memosens CPS62E is a pH sensor designed for challenging applications.
Product profile
The Endress + Hauser Memosens CPS72E is a digital ORP sensor designed for chemical process applications with rapidly changing values and high poison concentrations.
Product profile
The Memosens CPS92E is an ORP sensor designed for use in heavily polluted media, featuring an open aperture and low maintenance through gel filling.
Product profile
Orbisint CPS12, CPS12D, and CPS13 are ORP electrodes with Memosens technology for process and environmental applications, including water treatment.
Product profile
The Endress+Hauser CleanFit COA451 is a manually operated retractable assembly designed for oxygen sensors in water, wastewater, and industrial applications.
Product profile
The Endress + Hauser Memosens COS51E is an amperometric oxygen sensor for water, wastewater, and industrial utilities, featuring Memosens 2.0 technology for reliable data...
Product profile
The FlowFit COA250 is a PVC flow assembly for 40 mm diameter oxygen sensors, suitable for wastewater and surface water applications.
Product profile
The Liquiline CM442, CM444, and CM448 are multiparameter transmitters designed for industrial and environmental process monitoring using up to eight digital Memosens...
Product profile
The Endress + Hauser Liquisys M COM223/253 is a transmitter for oxygen sensors used in various water treatment applications.
Product profile
The Endress + Hauser Liquisys M COM223F-253F is a transmitter for dissolved oxygen sensors used in process control for enzyme and biotechnological production.
Product profile
This is an optical oxygen sensor for laboratory measurements and field sampling, featuring Memosens 2.0 digital technology.
Product profile
The Memosens COS22E is a hygienic amperometric oxygen sensor featuring Memosens 2.0 technology for applications in pharmaceuticals, biotechnology, and hazardous areas.
Product profile
This is a hygienic optical oxygen sensor utilizing Memosens 2.0 technology for applications in pharmaceutical fermenters, food quality control, and monitoring explosive...
Product profile
The Oxymax COS22 is a digital or analog sensor for residual oxygen measurement in pharmaceutical, chemical, and water treatment applications.
Product profile
The Oxymax COS61 is a digital optical sensor for measuring dissolved oxygen in wastewater, water monitoring, and water treatment applications.
Product profile
The Oxymax W COS41 is a potentiostatic amperometric two-electrode sensor for the continuous measurement of dissolved oxygen in various water management applications.
Product profile
The CYA251 is a universal flow assembly designed for nitrate/SAC, turbidity, and oxygen sensors in wastewater, drinking water, and industrial utility applications.
Product profile
The Ceraliquid CPS41 is a digital or analog pH electrode designed for process engineering with a ceramic diaphragm and KCl liquid electrolyte.
Product profile
The Ceramax CPS341D is a digital pH sensor with Memosens technology designed for pharmaceutical and food production applications.
Product profile
This is a digital pH sensor featuring Memosens technology designed for drinking water and swimming pool applications.
Product profile
The CTS1 is a temperature sensor designed for automatic temperature compensation in pH measurements and suitable for immersion or flow assemblies.
Product profile
The FlowFit CPA25 is a flow assembly designed for industrial auxiliary processes and water/wastewater treatment, accommodating up to three 12 mm sensors to maintain wet...
Product profile
The Endress + Hauser Liquiline CM14 is a four-wire transmitter designed for panel or cabinet installation, supporting pH, ORP, conductivity, and oxygen measurements.
Product profile
The Liquiline Compact CM72 is a space-saving, two-wire transmitter designed for monitoring and controlling industrial and environmental processes with digital Memosens...
Product profile
The Liquiline Compact CM82 is a configurable two-wire transmitter for Memosens sensors, supporting pH, ORP, conductivity, and oxygen measurements.
Product profile
The Liquiline CY42 is a DAT module for Endress+Hauser CM42 devices, offering configuration saving, firmware updates, and language changes.
Product profile
The Endress + Hauser Liquiline M CM42 is a two-wire transmitter designed for liquid analysis in process, pharmaceutical, and food technology applications, including...
Product profile
The Liquiline Mobile CML18 is a portable, multiparameter device designed for connecting digital sensors with Memosens technology.
Product profile
Memobase Plus CYZ71D is multichannel multiparameter software for managing the lifecycle of digital Memosens sensors used in liquid analysis.
Product profile
The Memocheck CYP02D and CYP03D are testing tools for analysis measuring points that utilize Memosens Technology for use in chemical, food, and wastewater applications.
Product profile
The Memocheck CYP02E is a maintenance-free service tool designed for on-site checking and configuration of Memosens transmitters.
Product profile
The Memosens CPS31E is a digital pH sensor designed for standard applications in drinking water and swimming pool water, offering Memosens 2.0 technology.
Product profile
The Memosens 61E is a sterilizable pH sensor for hygienic and sterile bioreactor applications in life sciences and the food industry.
Product profile
The Memosens CPF81E is a digital pH sensor designed for industrial water and wastewater treatment, as well as flotation and leaching applications.
Product profile
The Memosens CPL51E is a digital pH sensor with Memosens 2.0 technology designed for laboratory measurements and field sampling.
Product profile
The Memosens CPL53E is a digital pH sensor with Memosens 2.0 technology, ideal for standard laboratory measurements and random sampling.
Product profile
The Memosens CPL59E is a digital pH sensor utilizing Memosens 2.0 technology, featuring a PTFE junction and ion trap for demanding applications.
Product profile
The Memosens CPS11E is a digital pH sensor featuring Memosens 2.0 technology for use in standard process and environmental applications.
Product profile
The Memosens CPS16E is a pH/ORP sensor for standard applications in process technology and environmental engineering, capable of simultaneous pH, ORP, and rH measurements.
Product profile
The Endress + Hauser Memosens CPS41E is a digital pH sensor for low conductivity media and hazardous areas, featuring Memosens 2.0 technology for safe, digital data...
Product profile
This ISFET sensor is designed for accurate pH measurement in challenging media including clogging substances and organic solvents, featuring Memosens 2.0 digital...
Product profile
The Memosens CPS71E is a digital pH sensor designed for chemical process applications, featuring Memosens 2.0 technology and a poison-resistant reference system with an...
Product profile
The Endress+Hauser Memosens CPS76E is a pH/ORP sensor designed for process technology, suitable for challenging applications with rapidly changing pH values or high...
Product profile
This is an ISFET sensor for pH measurement in hygienic, sterile, and hazardous applications, featuring Memosens 2.0 technology for digital data transmission and sensor...
Product profile
This is a digital pH sensor with Memosens 2.0 technology designed for heavily polluted media, featuring an open aperture and ATEX, IECEx, CSA C/US, NEPSI, Japan, and...
Product profile
This Memosens CPS96E is a pH/ORP sensor designed for heavily polluted media with suspended solids, utilizing Memosens 2.0 technology and suitable for hazardous areas.
Product profile
The Memosens CPS97E is an ISFET sensor for pH measurement in contaminated media, including water treatment and wastewater applications.
Product profile
The Orbipore CPS91 is a pH electrode designed for chemical processes, pulp and paper, and flue gas cleaning, handling contaminated media and hazardous areas.
Product profile
This is an Orbitex W CPS21 pH sensor with an open ring junction for wastewater applications.
Product profile
The PuriSys CPF201 is a compact pH electrode designed for boiler feed water, power plant applications, and pharmaceutical WFI.
Product profile
The Topclean S CPC30 is an automatic measuring and cleaning system for pH/ORP applications in various industrial sectors, including process, wastewater, food, and...
Product profile
The CUA261 adapter is designed for installing Endress + Hauser optical sensors in VARIVENT process connections.
Product profile
The Memosens Wave CKI50 is an in-line process spectrometer used for analyzing liquids via VIS spectroscopy to detect and measure color, color variations, or color...
Product profile
The OUSAF11 is an optical sensor for VIS/NIR absorption measurement used for interphase detection and solids measurement in various industries.
Product profile
The OUSAF12 is an optical sensor for measuring VIS/NIR absorption in liquid media, suitable for applications in the chemical, pharmaceutical, and food and beverage...
Product profile
The OUSAF21 is an optical sensor designed for measuring low color concentrations, such as APHA/Hazen and potassium permanganate, in applications including outgoing goods...
Product profile
The OUSAF22 is an optical sensor for measuring color concentrations in visible light, suitable for color assurance and purity monitoring.
Product profile
The OUSAF44 is an optical sensor designed for UV absorption measurement in process liquids, suitable for applications like protein concentration and organic compound...
Product profile
The OUSAF46 is an optical sensor used with the OUA260 flow assembly for measuring UV absorption in process liquids.
Product profile
The OUSBT66 is a sensor from Endress+Hauser Liquid Analysis.
Product profile
The Endress + Hauser OUSTF10 is an optical sensor using the scattered light method for measuring turbidity and undissolved solids in process liquids.
Product profile
The Viomax CAS51D is a photometric sensor used for measuring spectral absorption coefficient (SAC) or nitrate content in water.
Product profile
The Memosens Wave CAS80E is a UV-VIS spectrometer for water analysis, measuring parameters like SAC, TOCeq, and turbidity.
Product profile
This Endress + Hauser TOC Analyzer CA78 utilizes UV digestion to measure total organic carbon in ultrapure water and features a stainless steel housing with an 8"...
Product profile
The Endress+Hauser CA79 is a TOC analyzer designed for ultrapure water applications with a conductivity less than 2 µS/cm.
Product profile
The TOCII CA72TOC is an analyzer designed for online measurement of Total Organic Carbon (TOC) in aqueous media using thermic catalytic combustion.
Product profile
The Turbimax CUA252 is a flow assembly designed for installing turbidity sensors in pipelines for water treatment applications.
Product profile
The Flowfit CUA262 is a stainless steel flow assembly designed for direct installation of the CUS52D turbidity sensor in process water skids and closed pipe systems.
Product profile
The Turbimax CUS51D is a versatile sensor designed for measuring turbidity and solids content in wastewater treatment applications.
Product profile
The Turbimax CUS71D is an ultrasonic interface sensor for accurate level measurement in water and wastewater treatment processes.
23 product profiles
Product profile
The Endress + Hauser Cerabar PMC11 is a pressure transducer for measuring gauge pressure in gases, vapors, liquids, and dust.
Product profile
The Cerabar M PMC51 is an analog process transmitter designed for pressure and level measurement.
Product profile
The Endress + Hauser Cerabar M PMC51B is a transmitter for measuring hydraulic pressure.
Product profile
The Endress + Hauser Cerabar S PMC71 is a pressure transmitter for absolute and gauge pressure measurements in gases, steams, and liquids.
Product profile
The Endress + Hauser Cerabar PMC71B is a robust transmitter for process pressure and level measurement in liquids or gases, featuring a ceramic process membrane and a...
Product profile
The Endress + Hauser Cerabar PMP23 is a pressure transducer for measuring absolute and gauge pressure in gases, vapors, liquids, and dust, suitable for hygienic...
Product profile
The Cerabar PMP43 is a compact digital transmitter designed for reliable pressure and hydrostatic level measurement.
Product profile
The Endress + Hauser Cerabar PMP50 is a pressure transmitter with a metal process membrane, suitable for absolute and gauge pressure measurements up to 400 bar.
Product profile
The Endress + Hauser Cerabar M PMP51 is a metallic process membrane transmitter for absolute and gauge pressure measurement in gases, steams, and liquids.
Product profile
The Cerabar M PMP51B is a digital pressure transmitter with a metallic process membrane for measuring absolute or gauge pressure in liquids or gases up to 400 bar.
Product profile
The Cerabar M PMP71B is a digital pressure transmitter for process and level measurement in liquids or gases.
Product profile
The Endress+Hauser Ceraphant PTC31B is a pressure switch designed for safe measurement and monitoring of absolute and gauge pressure in gases, vapors, liquids, and dust.
Product profile
The Ceraphant PTP33B is a versatile pressure switch for measuring absolute and gauge pressure in gases, liquids, vapors, and dust, suitable for hygienic applications.
Product profile
The Waterpilot FMX11 is a hydrostatic level transmitter designed for fresh water applications, including wells, rivers, and water towers.
Product profile
The Waterpilot FMX21 is a compact pressure transmitter designed for hydrostatic level measurement in various water applications.
Product profile
The Endress + Hauser Deltatop DP61D is a differential pressure flow measurement system utilizing Pitot tubes and Deltabar transmitters for gases, steam, and liquids.
Product profile
The Deltapilot M FMB50 is a pressure transmitter featuring a condensate-resistant CONTITE™ measuring cell for reliable hydrostatic pressure measurement in liquids and...
Product profile
The Deltabar S FMD71 is an electronic differential pressure transmitter with ceramic or metallic measuring cells, designed for level, volume, or mass measurement in...
Product profile
The Deltabar S FMD77 is a differential pressure transmitter with metallic measuring cells for gases, vapors, and liquids.
Product profile
The Deltabar M PMD55 is a differential pressure transmitter with a metallic measuring cell, suitable for flow, level, and differential pressure monitoring in gases,...
Product profile
The Deltabar M PMD55B is a digital differential pressure transmitter designed for applications with measuring ranges up to 40 bar.
Product profile
The Deltabar PMD75B is a digital differential pressure transmitter featuring a metal process membrane for various pressure measuring applications.
Product profile
The Deltabar S PMD78B is a digital differential pressure transmitter with a metallic process membrane used for measuring differential pressure, level, and flow.
71 product profiles
Product profile
The Endress+Hauser Easytemp TMR31 is a compact RTD thermometer for industrial and hygienic applications, utilizing a Pt100 sensor.
Product profile
The Endress + Hauser Omnigrad S TAF11 is a high temperature assembly designed for steel treatment and concrete furnaces.
Product profile
This resistance thermometer is designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries, with a measuring range of -50 to +200...
Product profile
The iTHERM ModuLine TM401 is a resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Product profile
Endress + Hauser RTD T13, T14, and T15 are explosion-proof RTD assemblies designed for heavy-duty applications in process industries.
Product profile
The Endress+Hauser T53, T54, and T55 are explosion-proof thermocouple assemblies for process industries, available with spring-loaded inserts and various enclosure...
Product profile
The RTD TH11 and TH12 are general-purpose resistance temperature detectors for process and laboratory applications, utilizing a Pt100 sensor according to IEC 60751.
Product profile
The Endress + Hauser RTD TH13, TH14, and TH15 are platinum resistance temperature detector assemblies for industrial process measurement.
Product profile
The iTherm Moduline TM101 is a versatile RTD or thermocouple thermometer designed for direct process installation, suitable for non-hazardous areas within a -50 to +1100...
Product profile
The Endress + Hauser iTherm Moduline TM111 is a robust, modular thermometer designed for direct installation in a wide temperature range of -200 to +1100 °C.
Product profile
The Endress+Hauser iTherm Moduline TM112 is a versatile industrial modular thermometer for universal use.
Product profile
The Endress + Hauser iTHERM Moduline TM121 is a metric thermometer designed for standard applications with replaceable inserts.
Product profile
The iTHERM Moduline TM131 is a modular RTD or TC thermometer for universal industrial use, offering temperature measurements from -200 to 1,100 °C and resisting...
Product profile
The iTHERM Moduline TM151 is a modular RTD or TC thermometer for universal industrial applications with a measuring range up to 1100 °C and pressure up to 500 bar.
Product profile
The Endress + Hauser iTherm Moduline TM152 is an industrial modular thermometer for universal use with a measuring range of up to 1,100 °C and pressures up to 500 bar.
Product profile
This Endress + Hauser iTHERM Compactline TM311 is a compact RTD thermometer designed for universal use in hygienic and aseptic industrial applications.
Product profile
The Endress + Hauser iTherm Moduline TM401 is a resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Product profile
The iTHERM Moduline TM411 is a modular resistance thermometer engineered for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Product profile
The iTHERM Moduline TST434B is a modular resistance thermometer for ambient temperature measurement, available with or without Endress+Hauser iTEMP temperature...
Product profile
The Omnigrad TST434 is an RTD thermometer designed for medium-duty applications in building automation, including outdoor ambient and wet environments.
Product profile
The Endress + Hauser TST602 is an RTD assembly designed for easy attachment to pipe or vessel surfaces for temperature measurement.
Product profile
The Endress + Hauser TR13 is a resistance thermometer and the TC13 is a thermocouple, suitable for universal applications up to 1,100 °C and 100 bar.
Product profile
The TR15 and TC15 are universal temperature sensors suitable for steam and gas applications, with static pressure ratings up to 400 bar and IP68 protection.
Product profile
The Endress + Hauser RTD TR66 and TC66 are modular, explosion-protected thermometers with barstock thermowells, designed for heavy-duty oil and gas applications.
Product profile
The Endress+Hauser RTD TR88 and TC88 are modular thermometers designed for installation in existing thermowells, offering protection up to IP68.
Product profile
This is a modular RTD assembly with a threaded process connection, suitable for a universal range of applications from -200 to 600 °C and up to 75 bar pressure.
Product profile
The Omnigrad-S TR15 and TC15 are thermocouple thermometers designed for heavy industrial steam and gas applications, featuring a modular DIN standard construction.
Product profile
The Endress + Hauser Omnigrad-S TR65 and TC65 are modular thermometers designed for use in fine chemicals, petrochemicals, power stations, and environmental engineering.
Product profile
The iTherm TT131 is a welded thermowell designed to protect temperature sensors in demanding industrial applications across chemical, oil & gas, and power sectors.
Product profile
The Endress + Hauser iTherm Moduline TT151 is a temperature transmitter designed for industrial applications.
Product profile
The Endress + Hauser iTherm Moduline TT152 is a barstock thermowell designed to protect thermometers from mechanical and chemical stress in pipes, vessels, or tanks.
Product profile
This modular thermometer is designed for use in the Oil & Gas industry, offering both Wire Wound and Thin Film RTD sensor options.
Product profile
This modular thermometer is designed for universal temperature measurement, with specific applications in the Oil & Gas industry.
Product profile
The Endress+Hauser iTherm Surfaceline TM611 is a non-invasive surface thermometer designed for demanding industrial applications.
Product profile
The Thermophant T TTR31 is a temperature switch with threaded connections or compression fitting, designed for monitoring, displaying, and controlling process...
Product profile
The Endress + Hauser iTEMP TMT31 is a Form B head-mounted temperature transmitter designed for high safety and availability with diagnostic functions.
Product profile
The Endress + Hauser iTEMP TMT36 is a temperature transmitter designed for reliability and high precision using RTD sensors.
Product profile
The iTEMP TMT71 is a universal temperature transmitter that converts various input signals into a scalable 4 to 20 mA output.
Product profile
The Endress+Hauser iTEMP TMT72 is a universal temperature transmitter with HART® communication, converting various input signals into a scalable 4-20 mA analog output.
Product profile
The Endress+Hauser iTEMP TMT80 is a programmable temperature head transmitter designed for converting resistance thermometer and thermocouple signals into a scalable 4 to...
Product profile
The Endress + Hauser iTEMP TMT82 is a dual-channel, SIL-compliant temperature transmitter designed for hazardous areas.
Product profile
The Endress+Hauser iTEMP TMT84 is a dual-input temperature transmitter with PROFIBUS PA output, designed for critical processes and hazardous areas.
Product profile
The iTEMP TMT85 is a dual-input temperature transmitter featuring FOUNDATION Fieldbus™ H1 protocol and universal inputs for RTDs, thermocouples, resistance, and voltage.
Product profile
The Endress + Hauser iTEMP TMT86 is a dual-input temperature transmitter supporting PROFINET with Ethernet-APL for system integration.
Product profile
The iTEMP TMT127 is a 2-wire Pt100 temperature transmitter for industrial use that features a 4 to 20 mA analog output.
Product profile
The Endress + Hauser iTemp TMT128 is a DIN rail mounted temperature transmitter for thermocouples, converting input signals into a scalable 4 to 20 mA output.
Product profile
The Endress+Hauser iTEMP TMT142B is a temperature field transmitter with HART and Bluetooth capabilities, converting various input signals into a scalable 4 to 20 mA...
Product profile
The Endress + Hauser iTemp TMT162 is a temperature field transmitter with two sensor inputs and an illuminated display.
Product profile
The Endress + Hauser iTEMP TMT182B is a universal temperature transmitter with HART® communication, converting various input signals into a scalable 4-20 mA analog output.
Product profile
This Endress + Hauser iTEMP TC TMT 188 is a temperature head transmitter designed for thermocouples that converts input signals to a 4 to 20 mA analog output.
Product profile
The Endress+Hauser TH51, TH52, and TH56 are general-purpose MgO insulated thermocouples designed for diverse process and laboratory temperature measurement applications.
Product profile
The Endress+Hauser TH53, TH54, and TH55 are magnesium oxide insulated thermocouple assemblies for installation in barstock thermowells across various process industries.
Product profile
The Endress + Hauser TSC310 is a thermocouple thermometer for temperature measurement in gaseous or liquid media.
Product profile
The Omnigrad TA550 is a heavy-duty industrial thermowell manufactured from drilled round bar stock, suitable for resistance and thermocouple thermometers.
Product profile
Designed for use with resistance and thermocouple thermometers, mainly in heavy duty applications.
Product profile
The Endress + Hauser Omnigrad TA556 is a heavy-duty industrial thermowell manufactured from drilled round bar stock for general-purpose use with resistance and...
Product profile
Omnigrad TA557 is part of this brand portfolio and is best compared by application duty, interface format, and operating conditions.
Product profile
The Omnigrad TA560 is a heavy-duty, general-purpose industrial thermowell designed for use with resistance and thermocouple thermometers.
Product profile
The Omnigrad TA562 is a heavy-duty, general-purpose industrial thermowell manufactured from hexagonal bar stock.
Product profile
The Omnigrad TA566 is a heavy-duty, general-purpose thermowell manufactured from hexagonal bar stock with a 1" NPT threaded process connection.
Product profile
Omnigrad TA570, TA571, TA572 is an online instrument or sensor product for water systems, best compared by measured parameter, range, mounting style, and signal interface.
Product profile
The Omnigrad TA575 and TA576 are heavy-duty industrial thermowells manufactured from round barstock for general-purpose temperature measurement.
Product profile
The Omnigrad TA730 is a protective sheath for temperature measurement instruments.
Product profile
The Endress + Hauser Omnigrad TW251 is a general industrial and hygienic thermowell designed for temperature measurement with integrated compression fittings.
Product profile
The Omnigrad M TW11 is a pipe thermowell with a threaded process connection, designed for fine chemicals and general industrial applications.
Product profile
The Endress + Hauser Omnigrad M TW15 is a heavy-duty, general-purpose thermowell designed for industrial processes with severe thermal and mechanical stresses.
Product profile
The Endress + Hauser iTherm Moduline TM412 is a modular resistance thermometer designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences...
Product profile
The Endress+Hauser iTherm TT511 is an industrial thermowell designed for demanding Oil & Gas and Petrochemical applications, featuring a flexible Vanstone design.
Product profile
The Endress + Hauser TA414 is a pipe thermowell designed for processes without strong flow.
Product profile
The TU51, TU52, TU53, and TU54 are heavy-duty thermowells manufactured from drilled barstock for RTD and thermocouple assemblies in process industries.
Product profile
The Endress + Hauser TWF11 and TWF16 are metal or ceramic thermowells designed for high-temperature applications.
Technical document
This guide details Endress + Hauser's comprehensive range of pH sensors, assemblies, and transmitters for industrial process applications.